| Item | Specifications | 
|---|---|
| Product Number | EX-F62 | 
| Part Number | EX-F62 | 
| Sensing object | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | 
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 
| Current consumption | 15 mA or less | 
| Output | NPN open-collector transistor – Maximum sink current: 50 mA – Applied voltage: 30 V DC or less (between output and 0 V) – Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) | 
| Output:Output operation | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | 
| Output:Short-circuit protection | Incorporated | 
| Response time | 50 ms or less | 
| FAULT indicator | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | 
| NORMAL indicator | Green LED (lights up when the sensor is mounted properly) | 
| Protection | IP67 (IEC) | 
| Ambient temperature | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ – 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | 
| Ambient illuminance | Incandescent light: 1,000 ℓx or less at the light-receiving face | 
| Emitting element | Infrared LED (non-modulated) | 
| Material | Enclosure: PFA | 
| Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | 
| Weight | Net weight: 60 g approx. | 
| Accessory | MS-EX-F6-2(PVC mounting bracket): 1 pc. | 
| Weight | 0.060 kg | 
|---|