Part Number: 1101320
Safety switches: FXL1-SPBUSA00
OEM Spec Ref
| Sensor principle | RFID | ||||||||
| Locking principle | Power to release | ||||||||
| Coding | Uniquely coded | ||||||||
|
|||||||||
|
|||||||||
| Actuation force | 20 N | ||||||||
| Retaining force | 30 N | ||||||||
| Force against which unlocking is possible | ≤ 25 N | ||||||||
| Actuation frequency | ≤ 1 Hz | ||||||||
| Approach speed | ≤ 20 m/min | ||||||||
| Safety integrity level | SIL 3 (IEC 61508) |
| Category | Category 4 (EN ISO 13849) 1) |
| Performance level | PL e (EN ISO 13849) 1) |
| PFHD (mean probability of a dangerous failure per hour) | 9.55 x 10-9 2) |
| TM (mission time) | 20 years (EN ISO 13849) |
| Type | Type 4 (EN ISO 14119) |
| Actuator coding level | High coding level (EN ISO 14119) |
| Safe state in the event of a fault | At least one safety-related semiconductor output (OSSD) is in the OFF state. |
| Auxiliary release | ✔ |
| Switching behavior of the OSSDs | Locking monitoring |
| Switching behavior of the application diagnostic output | Actuator monitoring |
| Safe series connections | In control cabinet (with diagnostics)
With Flexi Loop (with diagnostics) With T-connector (without diagnostics) |
| Display elements | LEDs |
| Diagnostics indicator | ✔ |
| Status display | ✔ |
| Protection class | III (IEC 61140) | ||||||
| Contamination rating | 3 (IEC 60947-1) | ||||||
| Classification according to cULus | Class 2 | ||||||
| Usage category | DC-13 (IEC 60947-5-3) | ||||||
| Rated insulation voltage Ui | 32 V | ||||||
| Rated impulse withstand voltage Uimp | 1,500 V | ||||||
| Supply voltage VS | 24 V DC (19.2 V DC … 28.8 V DC) | ||||||
|
|||||||
| Peak current | 800 mA, 200 ms | ||||||
|
|||||||
|
|||||||
| Output voltage | UV – 2 V DC … UV | ||||||
| Response time | ≤ 150 ms 1) | ||||||
| Release time | ≤ 350 ms 1) | ||||||
| Risk time | 150 ms 1) | ||||||
| Switch-on time | 3 s | ||||||
| Locking principle | Power to release | ||||||
1) In safe series connection: The value increases by 70 ms with each additional switch.
| Weight | 480 g | ||||||||||
|
|||||||||||
| Mechanical life | 1 x 106 switching cycles | ||||||||||
| Enclosure rating | IP65, IP67, IP69K (IEC 60529, IEC 60529, IEC 20653) |
| Ambient operating temperature | –20 °C … +55 °C |
| Storage temperature | –25 °C … +70 °C |
| Relative humidity | 10 % … 95 %, at 40 °C (IEC 60068) |
| Vibration resistance | 10 Hz … 55 Hz, 1 mm (IEC 60068-2-6) |
| Shock resistance | 30 g, 11 ms (EN 60068-2-27) |
| EMC | EN IEC 61326-3-1
EN IEC 60947-5-2 EN IEC 60947-5-3 EN 300330 |