SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1052453
Photoelectric Sensor Model: GSE6-N1112
OEM Spec Ref
Features
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Device type | Photoelectric sensors | ||||||||
Functional principle | Through-beam photoelectric sensor | ||||||||
Sensing range max. | 0 m … 15 m | ||||||||
Sensing range | 0 m … 10 m | ||||||||
Polarisation filters | No | ||||||||
|
|||||||||
|
|||||||||
Adjustment | None |
[/fusion_table]
- 1) Average service life: 100,000 h at TU = +25 °C.
Electrical data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Supply voltage UB | 10 V DC … 30 V DC 1) | ||||||||||||
Ripple | ± 10 % 2) | ||||||||||||
Power consumption | 30 mA 3) | ||||||||||||
Protection class | III | ||||||||||||
|
|||||||||||||
Switching mode | Light/dark switching | ||||||||||||
Switching mode selector | Selectable via light/dark selector | ||||||||||||
Circuit protection | A 7)
B 8) D 9) |
[/fusion_table]
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) At Uv > 24 V, IA max. = 50 mA.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) D = outputs overcurrent and short-circuit protected.
Mechanical data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Housing | Rectangular | ||||||||
Dimensions (W x H x D) | 12 mm x 31.5 mm x 21 mm | ||||||||
Connection | Cable, 3-wire, 2 m 1) | ||||||||
|
|||||||||
|
|||||||||
Weight | 170 g | ||||||||
Items supplied | Stainless steel mounting bracket (1.4301/304) BEF-W100-A |
[/fusion_table]
- 1) Do not bend below 0 °C.