SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1065875
Photoelectric Sensor Model: GTE10-R3822
OEM SpecRef
Functional principle | Photoelectric proximity sensor |
Functional principle detail | Energetic |
Dimensions (W x H x D) | 20 mm x 50 mm x 51.5 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 20 mm … 2,000 mm 1) |
Sensing range | 40 mm … 1,400 mm 1) |
Type of light | Infrared light |
Light source | LED 2) |
Light spot size (distance) | Ø 57 mm (1,500 mm) |
Wave length | 850 nm |
Adjustment | Potentiometer, 270° |
1) Object with 90% remission (based on standard white, DIN 5033).
2) Average service life: 100,000 h at TU = +25 °C.
Supply voltage UB | 24 V AC/DC … 240 V AC/DC 1) |
Ripple | < 10 % |
Power consumption | ≤ 2.5 VA |
Switching output | Relay, SPDT, electrically isolated 2) |
Switching load max. (current/voltage) | 0.11 A (250 V DC)
3 A (30 V DC) 3 A (250 V AC) |
Response time | ≤ 10 ms |
Switching frequency | 20 Hz 3) |
Connection type | Cable, 5-wire, 2 m 4) |
Cable material | Plastic, PVC |
Conductor cross section | 0.25 mm² |
Circuit protection | C 5) |
Protection class | II 6) |
Weight | 115 g |
Interference emission | EN 61000-6-3 (2011-09) 7) |
Housing material | Plastic, ABS/PMMA |
Enclosure rating | IP67 |
Relay switching cycles min. | 100.000 cycles (3 A) |
Items supplied | Mounting bracket BEF-G10UC01 |
Electromagnetic compatibility (EMC) | EN 60947-5-2 EN 61000-6-3 (2011-09) |
Ambient operating temperature | –30 °C … +60 °C 8) |
Ambient temperature, storage | –40 °C … +70 °C |
UL File No. | NRKH.E348498 & NRKH7.E348498 |
More standards | UL325 9) |
1) +- 10 %.
2) Provide suitable spark suppression for inductive or capacitive loads.
3) With light/dark ratio 1:1.
4) Do not bend below 0 °C.
5) C = interference suppression.
6) Reference voltage: 250 V AC.
7) In the case of a DC supply (ref. to EN 61000-6-3) the length of cable between the supply source and the sensor must be < 30 m.
8) UL: 0 °C … +50 °C.
9) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).
Weight | 0.221 kg |
---|