Contact Us:
sales@inosaki.com

GTE10-R3822 – Photoelectric Sensors – SICK Sensor

$ 125.35

SKU SICK 1065875 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1065875
Photoelectric Sensor Model: GTE10-R3822
OEM SpecRef 

Features

Functional principle Photoelectric proximity sensor
Functional principle detail Energetic
Dimensions (W x H x D) 20 mm x 50 mm x 51.5 mm
Housing design (light emission) Rectangular
Sensing range max. 20 mm … 2,000 mm 1)
Sensing range 40 mm … 1,400 mm 1)
Type of light Infrared light
Light source LED 2)
Light spot size (distance) Ø 57 mm (1,500 mm)
Wave length 850 nm
Adjustment Potentiometer, 270°

1) Object with 90% remission (based on standard white, DIN 5033).

2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage UB 24 V AC/DC … 240 V AC/DC 1)
Ripple < 10 %
Power consumption ≤ 2.5 VA
Switching output Relay, SPDT, electrically isolated 2)
Switching load max. (current/voltage) 0.11 A (250 V DC)

3 A (30 V DC)

3 A (250 V AC)

Response time ≤ 10 ms
Switching frequency 20 Hz 3)
Connection type Cable, 5-wire, 2 m 4)
Cable material Plastic, PVC
Conductor cross section 0.25 mm²
Circuit protection 5)
Protection class II 6)
Weight 115 g
Interference emission EN 61000-6-3 (2011-09) 7)
Housing material Plastic, ABS/PMMA
Enclosure rating IP67
Relay switching cycles min. 100.000 cycles (3 A)
Items supplied Mounting bracket BEF-G10UC01
Electromagnetic compatibility (EMC) EN 60947-5-2
EN 61000-6-3 (2011-09)
Ambient operating temperature –30 °C … +60 °C 8)
Ambient temperature, storage –40 °C … +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
More standards UL325 9)

1) +- 10 %.

2) Provide suitable spark suppression for inductive or capacitive loads.

3) With light/dark ratio 1:1.

4) Do not bend below 0 °C.

5) C = interference suppression.

6) Reference voltage: 250 V AC.

7) In the case of a DC supply (ref. to EN 61000-6-3) the length of cable between the supply source and the sensor must be < 30 m.

8) UL: 0 °C … +50 °C.

9) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).

Additional information

Weight 0.221 kg

Related Products

M6
MOXA_Unmanaged_Switches_MOXA EDS-2016-ML
CN-73-C1
SICK_sensor_Photoelectric_sensor_W100-2_WS WE100-2P3439
Schneider_Programmable Logic Controllers_TM241C24U
IDS_Camera_uEye+_LE_AF_BoardLevel_S_Mount_1
Select your currency