| Item | H7CC-A8/-A11[] | H7CC-A[] | H7CC-AW[]/AU[] | 
| Classification | Preset counter | Preset counter/ tachometer | 
| Configuration | 1-stage preset counter, 1-stage preset counter with total counter (selectable) *1 | 1-stage/2-stage preset counter, total and preset counter *1,
 batch counter, dual counter,
 twin counter, and tachometer
 (selectable)
 | 
| Ratings | Power supply voltage *2
 | • 100 to 240 VAC, 50/60 Hz • 24 VAC, 50/60 Hz or 12 to 48 VDC
 | 
| Operating voltage
 fluctuation
 range
 | 85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%) | 
| Power consumption
 | Approx. 6.8 VA at 100 to 240 VAC, Approx. 5.5 VA/3.3 W at 24 VAC/12 to 48 VDC,
 | 
| Mounting method | Flush mounting or surface mounting | Flush mounting | 
| External connections | 8-pin/ 11-pin socket | Screw terminals | 
| Degree of protection | IEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used. | 
| Input signals | CP1, CP2, reset, and total reset *4 | CP1, CP2, reset 1, and reset 2 | 
| Counter | Maximum counting
 speed
 | 30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
 | 
| Input mode
 | Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs) | 
| Output mode
 | N, F, C, R, K-1, P, Q, A, K-2, D, and L. | N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. | 
| One-shot out put
 time
 | 0.01 to 99.99 s | 
| Reset system
 | External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation) | 
| Tachometer | Refer to the tachometer function ratings. | 
| Prescaling function | Yes (0.001 to 99.999) | 
| Decimal point adjustment | Yes (right most 3 digits) | 
| Sensor waiting time | 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) | 
| Input method | No-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs:
 ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max.
 OFF impedance: 100 kΩ min.
 Voltage input:
 High (logic) level: 4.5 to 30 VDC
 Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
 | 
| External power supply | 12 VDC (±10%), 100 mA (except for H7CC-A8[] models) Refer to Precautions for Correct Use on Catalog for details. | 
| Control output | • Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
 • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V),
 Leakage current: 0.1 mA max.
 | 
| Display *3 | 7-segment, negative transmissive LCD Character height
 Count value: 10 mm (white)
 Set value: 6 mm (green)
 | 
| Digits | 6 digits -99999 to 999999
 (-5 digits to +6 digits)
 | 6 digits -99999 to 999999
 (-5 digits to +6 digits),
 tachometer: 0 to 999999
 | 
| Memory backup | Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min. | 
| Operating temperature range | -10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) | 
| Storage temperature range | -25 to 70°C (with no icing or condensation) | 
| Operating humidity range | 25% to 85% | 
| Case color | Black (N1.5) | 
| Attachments | — | Flush mounting adapter, waterproof packing, terminal cover |