Main |
Part Number |
XB4BS8444 |
XB4BS8445 |
Range of product |
Harmony XB4 |
Harmony XB4 |
Product or component type |
Emergency stop push-button |
Emergency switching off push-button |
|
Emergency switching off push-button |
Emergency stop push-button |
device short name |
XB4 |
XB4 |
Bezel material |
Chromium plated metal |
Chromium plated metal |
Fixing collar material |
Zamak |
Zamak |
Mounting diameter |
22 mm |
22 mm |
Sale per indivisible quantity |
1 |
1 |
Shape of signaling unit head |
Round |
Round |
Type of operator |
Trigger action and mechanical latching |
Trigger action and mechanical latching |
Head type |
Standard |
Standard |
reset |
Turn to release |
Turn to release |
Operator profile |
Red mushroom Ø 40 mm, unmarked |
Red mushroom Ø 40 mm, unmarked |
Contact operation |
Slow-break |
Slow-break |
Connections – terminals |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1 |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1 |
|
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1 |
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1 |
Complementary |
Height |
47 mm |
47 mm |
Width |
40 mm |
40 mm |
Depth |
82 mm |
82 mm |
Terminals description ISO n°1 |
(21-22)NC |
(13-14)NO |
Product weight |
0.13 kg |
0.13 kg |
Resistance to high pressure washer |
7000000 Pa at 55 °C, distance : 0.1 m |
7000000 Pa at 55 °C, distance : 0.1 m |
Contacts usage |
Standard contacts |
Standard contacts |
Positive opening |
With conforming to EN/IEC 60947-5-1 appendix K |
With conforming to EN/IEC 60947-5-1 appendix K |
Operating travel |
1.5 mm (NC changing electrical state) |
1.5 mm (NC changing electrical state) |
|
4.3 mm (total travel) |
2.6 mm (NO changing electrical state) |
|
|
4.3 mm (total travel) |
|
|
44 N |
Mechanical durability |
300000 cycles |
300000 cycles |
Tightening torque |
0.8…1.2 N.m conforming to EN 60947-1 |
0.8…1.2 N.m conforming to EN 60947-1 |
Shape of screw head |
Cross compatible with Philips no 1 screwdriver |
Cross compatible with Philips no 1 screwdriver |
|
Cross compatible with pozidriv No 1 screwdriver |
Cross compatible with pozidriv No 1 screwdriver |
|
Slotted compatible with flat Ø 4 mm screwdriver |
Slotted compatible with flat Ø 4 mm screwdriver |
|
Slotted compatible with flat Ø 5.5 mm screwdriver |
Slotted compatible with flat Ø 5.5 mm screwdriver |
Contacts material |
Silver alloy (Ag/Ni) |
Silver alloy (Ag/Ni) |
Short-circuit protection |
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 |
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 |
[Ith] conventional free air thermal current |
10 A conforming to EN/IEC 60947-5-1 |
10 A conforming to EN/IEC 60947-5-1 |
[Ui] rated insulation voltage |
600 V (pollution degree 3) conforming to EN 60947-1 |
600 V (pollution degree 3) conforming to EN 60947-1 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN 60947-1 |
6 kV conforming to EN 60947-1 |
[Ie] rated operational current |
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
|
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
|
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
|
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
|
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 |
|
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
Electrical durability |
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
|
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
|
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
|
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
|
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
Electrical reliability |
Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 |
Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 |
|
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 |
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 |
Device presentation |
Complete product |
Complete product |
Environment |
Protective treatment |
TH |
TH |
Ambient air temperature for storage |
-40…70 °C |
-40…70 °C |
Ambient air temperature for operation |
-40…70 °C |
-40…70 °C |
Electrical shock protection class |
Class I conforming to IEC 60536 |
Class I conforming to IEC 60536 |
IP degree of protection |
IP66 conforming to IEC 60529 |
IP66 conforming to IEC 60529 |
|
IP67 |
IP67 |
|
IP69 |
IP69 |
|
IP69K |
IP69K |
NEMA degree of protection |
NEMA 13 |
NEMA 13 |
|
NEMA 4X |
NEMA 4X |
IK degree of protection |
IK06 conforming to IEC 50102 |
IK06 conforming to IEC 50102 |
Standards |
JIS C8201-5-1 |
EN/IEC 60204-1 |
|
IEC 60364-5-53 |
EN/IEC 60947-1 |
|
UL 508 |
UL 508 |
|
EN/IEC 60947-5-1 |
IEC 60364-5-53 |
|
CSA C22.2 No 14 |
EN/ISO 13850 |
|
EN/ISO 13850 |
CSA C22.2 No 14 |
|
EN/IEC 60947-5-5 |
EN/IEC 60947-5-1 |
|
EN/IEC 60947-1 |
EN/IEC 60947-5-4 |
|
EN/IEC 60204-1 |
JIS C8201-5-1 |
|
EN/IEC 60947-5-4 |
EN/IEC 60947-5-5 |
|
JIS C8201-1 |
JIS C8201-1 |
Product certifications |
LROS (Lloyds register of shipping) |
BV |
|
BV |
GL |
|
GL |
LROS (Lloyds register of shipping) |
|
DNV |
DNV |
|
CSA |
CSA |
|
UL listed |
UL listed |
Vibration resistance |
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance |
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
|
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
Packing Units |
|
|
Unit Type of Package 1 |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
Package 1 Height |
4.700 cm |
5.200 cm |
Package 1 Width |
5.500 cm |
4.400 cm |
Package 1 Length |
9.400 cm |
8.800 cm |
Package 1 Weight |
133.000 g |
133.000 g |
Unit Type of Package 2 |
S03 |
S03 |
Number of Units in Package 2 |
80 |
80 |
Package 2 Height |
30.000 cm |
30.000 cm |
Package 2 Width |
30.000 cm |
30.000 cm |
Package 2 Length |
40.000 cm |
40.000 cm |
Package 2 Weight |
11.113 kg |
11.172 kg |
Unit Type of Package 3 |
P06 |
P06 |
Number of Units in Package 3 |
640 |
640 |
Package 3 Height |
75.000 cm |
77.000 cm |
Package 3 Width |
60.000 cm |
80.000 cm |
Package 3 Length |
80.000 cm |
60.000 cm |
Package 3 Weight |
99.964 kg |
99.324 kg |
Contractual warranty |
Warranty |
18 months |
|