Contact Us:
sales@axmatic.com

IM18-05BUS-ZU0 Inductive Proximity Sensors – SICK Sensor

$ 117.30

SKU SICK 7902122 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 7902122
Inductive proximity Sensor Model: IM18-05BUS-ZU0
OEM Spec Ref 

Features

Housing Cylindrical thread design
Housing Standard
Thread size M18 x 1
Diameter Ø 18 mm
Sensing range Sn 5 mm
Safe sensing range Sa 4.05 mm
Installation type Flush
Switching frequency 25 Hz 1)

100 Hz 2)

Connection type Cable, 2-wire, 2 m
Output function NO
Electrical wiring AC/DC 2-wire
Enclosure rating IP67 3)
  • 1) AC.
  • 2) DC.
  • 3) According to EN 60529.

Mechanics/electronics

Supply voltage 20 V AC/DC … 250 V AC/DC
Voltage drop ≤ 6.5 V AC, ≤ 6 V DC
Time delay before availability ≤ 8 ms
Hysteresis 1 % … 15 %
Reproducibility ≤ 10 % 1) 2) 3)
Temperature drift (of Sr) ± 10 %
EMC As per EN 55011, class B
Continuous current Ia ≤ 350 mA 4)

≤ 250 mA 5)

≤ 100 mA 6)

Off-state current ≤ 2.5 mA (AC 250 V)

≤ 1.3 mA (AC 110 V)

≤ 0.8 mA (DC 24 V)

Minimum load current ≥ 5 mA
Short-time withstand current 2.2 A 7)
Cable material PUR
Conductor size 0.5 mm²
Short-circuit protection – 8)
Power-up pulse protection
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature –25 °C … +80 °C
Housing material Brass, nickel-plated
Sensing face material Plastic, PBT
Housing length 80 mm
Thread length 58 mm
Tightening torque, max. ≤ 35 Nm
Items supplied Mounting nut, brass, nickel-plated (2x)
Protection class II
Rated insulation voltage Ui 250 V AC
Usage category AC-140 9)

DC-13 10)

Contamination rating 3
Rated impulse withstand voltage 4 kV
  • 1) Ub and Ta constant.
  • 2) Of Sr.
  • 3) Repeatability (Ta not constant).
  • 4) AC (+50 °C).
  • 5) AC (+80 °C).
  • 6) DC.
  • 7) 20 ms / 0.5 Hz.
  • 8) Miniature fuse to IEC 60217-2 Sheet 1, ≤ 2 A (quick-blow).
  • 9) Control of small electromagnetic loads with holding currents < 200 mA.
  • 10) Control of solenoids.

Additional information

Related Products

PEPPERL+FUCHS_Inductive Sensor_NBB15-U1-E2_1
M3
Phoenix Contact_Current And Voltage Measuring Technology_MACX MCR-VAC
SICK_sensor_Photoelectric_sensor_MultiLine_WTB4-3E1392S88
Computar_Telecentric Lens_TEC-M55MPW
SICK_sensor_Contrast_sensor_KTM Prime_KTM_WP1A282V
Select your currency