SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1040764
Inductive proximity Sensor Model: IME12-04BPSZC0S
OEM Spec Ref
Features
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Housing | Cylindrical thread design |
Housing | Standard |
Thread size | M12 x 1 |
Diameter | Ø 12 mm |
Sensing range Sn | 4 mm |
Safe sensing range Sa | 3.24 mm |
Installation type | Flush |
Switching frequency | 2,000 Hz |
Connection type | Male connector M12, 4-pin |
Switching output | PNP |
Output function | NO |
Electrical wiring | DC 3-wire |
[/fusion_table]
- 1) According to EN 60529.
Mechanics/electronics
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Supply voltage | 10 V DC … 30 V DC |
Ripple | ≤ 10 % |
Voltage drop | ≤ 2 V 1) |
Current consumption | 10 mA 2) |
Time delay before availability | ≤ 100 ms |
Hysteresis | 5 % … 15 % |
Reproducibility | ≤ 2 % 3) 4) |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-2 |
Continuous current Ia | ≤ 200 mA |
Short-circuit protection | ✔ |
Reverse polarity protection | ✔ |
Power-up pulse protection | ✔ |
Shock and vibration resistance | 30 g, 11 ms/10 Hz … 55 Hz, 1 mm |
Ambient operating temperature | –25 °C … +75 °C |
Housing material | Brass, nickel-plated |
Sensing face material | Plastic, PA 66 |
Housing length | 65 mm |
Thread length | 48 mm |
Tightening torque, max. | ≤ 12 Nm |
Items supplied | Mounting nut, brass, nickel-plated (2x) |
UL File No. | NRKH.E181493 |
[/fusion_table]
- 1) At Ia max.
- 2) Without load.
- 3) Ub and Ta constant.
- 4) Of Sr.