Main information |
Part Number |
GV2L07 |
GV2L20 |
Product Series |
TeSys Deca |
TeSys Deca |
product name |
TeSys GV2 |
TeSys GV2 |
|
TeSys Deca |
TeSys Deca |
product type |
Motor circuit breaker |
Motor circuit breaker |
product short name |
Wxya |
Wxya |
Applications |
Motor protection |
Motor protection |
Trip unit type |
Magnetic |
Magnetic |
Additional information |
number of poles |
3P |
3P |
Grid type |
AC |
AC |
use category |
Type AC conforms to IEC 60947-2 |
Type AC conforms to IEC 60947-2 |
|
AC-3 conforms to IEC 60947-4-1 |
AC-3 conforms to IEC 60947-4-1 |
Network frequency |
50/60 Hz conforming to IEC 60947-2 |
50/60 Hz conforming to IEC 60947-2 |
fixed mode |
35 mm DIN rail: clipped |
35 mm DIN rail: clipped |
|
Panel: screw type (with 2 x M4 screws) |
Panel: screw type (with 2 x M4 screws) |
Motor power (kW) |
0.75 kW at 400/415 V AC 50/60 Hz |
7.5 kW at 400/415 V AC 50/60 Hz |
|
1.1 kW at 500 V AC 50/60 Hz |
9 kW at 500 V AC 50/60 Hz |
|
1.5 kW at 690 V AC 50/60 Hz |
15 kW at 690 V AC 50/60 Hz |
Breaking capacity |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 |
20 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 |
|
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
|
4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated operating short-circuit breaking capacity [Ics] |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
|
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
control type |
Rotary handle |
Rotary handle |
Rated current [In] |
2.5A |
18A |
Electromagnetic trip current |
33.5A |
223A |
Conventional thermal current [Ith] |
2.5 A conforming to IEC 60947-4-1 |
18 A conforming to IEC 60947-4-1 |
Rated working voltage [Ue] |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated impulse withstand voltage [Uimp] |
6 kV according to IEC 60947-2 |
6 kV according to IEC 60947-2 |
isolation function |
Applies to IEC 60947-1 § 7-1-6 |
Applies to IEC 60947-1 § 7-1-6 |
power consumption per pole |
1.8W |
1.8W |
Mechanical life |
100000 times |
100000 times |
Electrical life |
100000 cycles for AC-3 at 415 V In |
100000 cycles for AC-3 at 415 V In |
specified load |
Continuous according to IEC 60947-4-1 |
Continuous according to IEC 60947-4-1 |
Tightening torque |
1.7 Nm via screw-in terminals |
1.7 Nm via screw-in terminals |
width |
45 mm |
45 mm |
high |
89 mm |
89 mm |
depth |
97 mm |
97 mm |
product weight |
0.33kg |
0.33kg |
color |
Dark gray |
Dark gray |
Environment |
Standards compliant |
TM-D |
TM-D |
|
EN/IEC 60947-4-1 |
EN/IEC 60947-4-1 |
|
UL 60947-4-1 |
UL 60947-4-1 |
|
DIN 3852-Y |
|
certified product |
CCC |
CCC |
|
UL |
UL |
|
CSA |
CSA |
|
EAC |
EAC |
|
LROS (Lloyds register of shipping) |
LROS (Lloyds register of shipping) |
|
BV |
BV |
|
RINA |
RINA |
|
DNV-GL |
DNV-GL |
|
UKCA |
UKCA |
|
IECEE CB Scheme |
IECEE CB Scheme |
IK protection class |
IK04 |
IK04 |
IP protection class |
IP20 complies with screwed |
IP20 complies with screwed |
climate tolerance |
Conforms to IACS E10 |
Conforms to IACS E10 |
storage environment temperature |
-40…80°C |
-40…80°C |
Fire resistance and abnormal high temperature resistance |
960 °C conforming to IEC 60695-2-11 |
960 °C conforming to IEC 60695-2-11 |
ambient temperature |
-20…60°C |
-20…60°C |
Shock and vibration resistance |
Shock resistance: 30 Gn for 11 ms |
Shock resistance: 30 Gn for 11 ms |
|
Shock resistance: 5 gn (5…150 Hz) |
Shock resistance: 5 gn (5…150 Hz) |
working altitude |
2000 meters |
2000 meters |
Packaging unit |
Unit Type of Package 1 |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
Package 1 Height |
4.800 cm |
9.300 cm |
Package 1 Width |
9.500 cm |
4.600 cm |
Package 1 Length |
10.300 cm |
10.000 cm |
Package 1 Weight |
320.000g |
330.000g |
Unit Type of Package 2 |
S02 |
S02 |
Number of Units in Package 2 |
20 |
20 |
Package 2 Height |
15.000 cm |
15.000 cm |
Package 2 Width |
30.000 cm |
30.000 cm |
Package 2 Length |
40.000 cm |
40.000 cm |
Package 2 Weight |
6.593 kg |
6.930kg |
Unit Type of Package 3 |
P06 |
|
Number of Units in Package 3 |
320 |
|
Package 3 Height |
75.000 cm |
|
Package 3 Width |
60.000 cm |
|
Package 3 Length |
80.000 cm |
|
Package 3 Weight |
113.490kg |
|
Contract warranty |
Warranty |
18 months |
18 months |