Main |
Part Number |
XCKD2121P16 |
XCKD2102P16 |
XCKD2106P16 |
XCKD2110P16 |
Range of product |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Series name |
Standard format |
Standard type |
Standard type |
Standard type |
Product or component type |
Limit switch |
Limit switch |
Limit switch |
Limit switch |
device short name |
XCKD |
XCKD |
XCKD |
XCKD |
Sensor design |
Compact form E conforming to CENELEC EN 50047 |
Compact Type C according to CENELEC EN 50047 |
Compact |
Compact Type B according to CENELEC EN 50047 |
body type |
Fixed |
Fixed |
Fixed |
Fixed |
Head type |
Plunger head |
Direct acting head |
Universal head |
Direct acting head |
Material |
Metal |
Metal |
Metal |
Metal |
Body material |
Zamak |
Zamak |
Zamak |
Zamak |
Head material |
Zamak |
Zamak |
Zamak |
Zamak |
Fixing mode |
By the body |
By ontology |
By ontology |
By ontology |
Movement of operating head |
Linear |
Linear |
Universal |
Linear |
Type of operator |
Spring return roller lever plunger thermoplastic |
Spring Return, Roller Direct Action Metal |
Spring return whisker |
Spring return direct acting metal |
Type of approach |
Lateral approach, 1 direction |
Lateral movement, 2-way |
Universal motion |
Vertical movement, one-way |
Number of poles |
2 |
2 |
2 |
2 |
Contacts type and composition |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
Contact operation |
Snap action |
Momentary |
Momentary |
Momentary |
Complementary |
Switch actuation |
By 30° cam |
30° lip |
Any moving parts |
The end |
Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Cable entry |
1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
One for M16x1.5 cable gland, cable outer diameter: 4…8 mm |
One for M16x1.5 cable gland, cable outer diameter: 4…8 mm |
One for M16x1.5 cable gland, cable outer diameter: 4…8 mm |
Contacts insulation form |
Zb |
Zb |
Zb |
Zb |
Positive opening |
With |
Have |
None |
Have |
Positive opening minimum force |
18 N |
36 N |
|
45N |
Minimum trigger torque |
|
|
0.13 Nm |
|
Minimum force for tripping |
6 N |
12N |
|
15N |
minimum braking speed |
|
|
|
0.01 m/min |
Maximum actuation speed |
1 m/s |
0.5 m/s |
1 m/s |
0.5 m/s |
Repeat accuracy |
0.1 mm on the tripping points with 1 million operating cycles |
Trigger point is 0.1mm 1 million operating cycles |
Trigger point is 0.1mm 1 million operating cycles |
Trigger point is 0.1mm 1 million operating cycles |
Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
|
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to IEC 60947-5-1 appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A |
|
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 |
|
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A |
[Ui] rated insulation voltage |
300 V conforming to UL 508 |
300 V according to UL 508 |
300 V according to UL 508 |
300 V according to UL 508 |
|
500 V (pollution degree 3) conforming to IEC 60947-1 |
500 V (pollution degree 3) according to IEC 60947-1 |
500 V (pollution degree 3) according to IEC 60947-1 |
500 V (pollution degree 3) according to IEC 60947-1 |
|
300 V conforming to CSA C22.2 No 14 |
300 V according to CSA C22.2 No 14 |
300 V according to CSA C22.2 No 14 |
300 V according to CSA C22.2 No 14 |
Maximum resistance across terminals |
25 MOhm conforming to IEC 60255-7 category 3 |
25 MΩ conforming to IEC 60255-7 Safety Class 3 |
25 MΩ conforming to IEC 60255-7 Safety Class 3 |
25 MΩ conforming to IEC 60255-7 Safety Class 3 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 |
6 kV according to IEC 60664 |
6 kV according to IEC 60664 |
6 kV according to IEC 60664 |
|
6 kV conforming to IEC 60947-1 |
6 kV according to IEC 60947-1 |
6 kV according to IEC 60947-1 |
6 kV according to IEC 60947-1 |
Short-circuit protection |
10 A cartridge fuse, type gG |
10 A fuse fuse, type gG |
10 A fuse fuse, type gG |
10 A fuse fuse, type gG |
Electrical durability |
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W |
5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W |
5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W |
|
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C |
, Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C |
, Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C |
, Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C |
|
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C |
5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C |
5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C |
Mechanical durability |
15000000 cycles |
10000000 times |
5000000 times |
15000000 times |
Width |
31 mm |
31 mm |
31 mm |
31 mm |
Height |
65 mm |
65 mm |
65 mm |
65 mm |
Depth |
30 mm |
30 mm |
30 mm |
30 mm |
Product weight |
0.195 kg |
0.185kg |
0.175kg |
0.18kg |
Terminals description ISO n°1 |
(13-14)NO |
(21-22)NC |
(21-22)NC |
(21-22)NC |
|
(21-22)NC |
(13-14)NO |
(13-14)NO |
(13-14)NO |
Environment |
Shock resistance |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection |
IP66 conforming to IEC 60529 |
IP66 conforms to screwed |
IP66 conforms to screwed |
IP66 conforms to screwed |
|
IP67 conforming to IEC 60529 |
IP67 conforms to screwed |
IP67 conforms to screwed |
IP67 conforms to screwed |
IK degree of protection |
IK06 conforming to EN 50102 |
IK06 conforms to EN 50102 |
IK06 conforms to EN 50102 |
IK06 conforms to EN 50102 |
Electrical shock protection class |
Class I conforming to IEC 61140 |
Class I conforming to IEC 61140 |
Class I conforming to IEC 61140 |
Class I conforming to IEC 61140 |
|
Class I conforming to NF C 20-030 |
Class I conforming to NF C 20-030 |
Class I conforming to NF C 20-030 |
Class I conforming to NF C 20-030 |
Ambient air temperature for operation |
-25…70 °C |
-25…70°C |
-25…70°C |
-25…70°C |
Ambient air temperature for storage |
-40…70 °C |
-40…70°C |
-40…70°C |
-40…70°C |
Protective treatment |
TC |
TC |
TC |
TC |
Product certifications |
UL |
CCC |
CCC |
CCC |
|
CSA |
UL |
CSA |
UL |
|
CCC |
CSA |
UL |
CSA |
Standards |
EN 60947-5-1 |
IEC 60947-5-1 |
IEC 60947-5-1 |
IEC 60947-5-1 |
|
IEC 60947-5-1 |
CSA C22.2 No 14 |
CSA C22.2 No 14 |
EN 60947-5-1 |
|
UL 508 |
IEC 60204-1 |
EN 60204-1 |
CSA C22.2 No 14 |
|
IEC 60204-1 |
EN 60204-1 |
EN 60947-5-1 |
IEC 60204-1 |
|
EN 60204-1 |
UL 508 |
UL 508 |
EN 60204-1 |
|
CSA C22.2 No 14 |
EN 60947-5-1 |
IEC 60204-1 |
UL 508 |
Packing Units |
Unit Type of Package 1 |
PCE |
PCE |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
1 |
1 |
Package 1 Height |
3.5 cm |
3.0cm |
3.4cm |
3.8cm |
Package 1 Width |
4.0 cm |
5.0cm |
4cm |
5.4 cm |
Package 1 Length |
10.3 cm |
11.8 cm |
20.6cm |
10.2 cm |
Package 1 Weight |
174.0 g |
166.0g |
168g |
160.0g |
Unit Type of Package 2 |
S01 |
S01 |
S01 |
S01 |
Number of Units in Package 2 |
22 |
22 |
12 |
27 |
Package 2 Height |
15.0 cm |
15.0cm |
15cm |
15.0cm |
Package 2 Width |
15.0 cm |
15.0cm |
15cm |
15.0cm |
Package 2 Length |
40.0 cm |
40.0cm |
40cm |
40.0cm |
Package 2 Weight |
4.091 kg |
3.918 kg |
2.349 kg |
4.642kg |
Contractual warranty |
Warranty |
18 months |
18 month |
18 months |
18 months |