Main |
Part Number |
XCKT2102P16 |
XCKT2111P16 |
XCKT2110P16 |
Range of product |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Series name |
Standard format |
Standard format |
Standard format |
Product or component type |
Limit switch |
Limit switch |
Limit switch |
device short name |
XCKT |
XCKT |
XCKT |
Sensor design |
Compact form C conforming to CENELEC EN 50047 |
Compact |
Compact form B conforming to CENELEC EN 50047 |
body type |
Fixed |
Fixed |
Fixed |
Head type |
Plunger head |
Plunger head |
Plunger head |
Material |
Plastic |
Plastic |
Plastic |
Body material |
Plastic |
Plastic |
Plastic |
Head material |
Zamak |
Zamak |
Zamak |
Fixing mode |
By the body |
By the body |
By the body |
Movement of operating head |
Linear |
Linear |
Linear |
Type of operator |
Spring return roller plunger metal |
Spring return roller plunger metal with nitrile boot |
Spring return plunger metal |
Type of approach |
Lateral approach, 2 directions |
Vertical approach, 1 direction |
Vertical approach, 1 direction |
Number of poles |
2 |
2 |
2 |
Contacts type and composition |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
Contact operation |
Snap action |
Snap action |
Snap action |
Complementary |
Switch actuation |
By 30° cam |
On end |
On end |
Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Cable entry |
2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
Contacts insulation form |
Zb |
Zb |
Zb |
Positive opening |
With |
With |
With |
Positive opening minimum force |
36 N |
45 N |
45 N |
Minimum force for tripping |
12 N |
15 N |
15 N |
Maximum actuation speed |
0.5 m/s |
0.01 m/min |
0.01 m/min |
Repeat accuracy |
0.1 mm on the tripping points with 1 million operating cycles |
0.5 m/s |
0.5 m/s |
Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A |
0.1 mm on the tripping points with 1 million operating cycles |
0.1 mm on the tripping points with 1 million operating cycles |
|
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A |
[Ui] rated insulation voltage |
300 V conforming to UL 508 |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
|
500 V (pollution degree 3) conforming to IEC 60947-1 |
300 V conforming to UL 508 |
300 V conforming to UL 508 |
|
300 V conforming to CSA C22.2 No 14 |
500 V (pollution degree 3) conforming to IEC 60947-1 |
500 V (pollution degree 3) conforming to IEC 60947-1 |
Maximum resistance across terminals |
25 MOhm conforming to IEC 60255-7 category 3 |
300 V conforming to CSA C22.2 No 14 |
300 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 |
25 MOhm conforming to IEC 60255-7 category 3 |
25 MOhm conforming to IEC 60255-7 category 3 |
|
6 kV conforming to IEC 60947-1 |
6 kV conforming to IEC 60664 |
6 kV conforming to IEC 60664 |
Short-circuit protection |
10 A cartridge fuse, type gG |
6 kV conforming to IEC 60947-1 |
6 kV conforming to IEC 60947-1 |
Electrical durability |
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
10 A cartridge fuse, type gG |
10 A cartridge fuse, type gG |
|
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
|
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
|
|
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability |
10000000 cycles |
15000000 cycles |
15000000 cycles |
Width |
58 mm |
58 mm |
58 mm |
Height |
51 mm |
51 mm |
51 mm |
Depth |
30 mm |
30 mm |
30 mm |
Product weight |
0.105 kg |
0.1 kg |
0.1 kg |
Terminals description ISO n°1 |
(21-22)NC |
(13-14)NO |
(21-22)NC |
|
(13-14)NO |
(21-22)NC |
(13-14)NO |
Environment |
Shock resistance |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection |
IP66 conforming to IEC 60529 |
IP66 conforming to IEC 60529 |
IP66 conforming to IEC 60529 |
|
IP67 conforming to IEC 60529 |
IP67 conforming to IEC 60529 |
IP67 conforming to IEC 60529 |
IK degree of protection |
IK04 conforming to EN 50102 |
IK04 conforming to EN 50102 |
IK04 conforming to EN 50102 |
Electrical shock protection class |
Class II conforming to IEC 61140 |
Class II conforming to IEC 61140 |
Class II conforming to IEC 61140 |
|
Class II conforming to NF C 20-030 |
Class II conforming to NF C 20-030 |
Class II conforming to NF C 20-030 |
Ambient air temperature for operation |
-25…70 °C |
-25…70 °C |
-25…70 °C |
Ambient air temperature for storage |
-40…70 °C |
-40…70 °C |
-40…70 °C |
Protective treatment |
TC |
TC |
TC |
Product certifications |
CSA |
UL |
CCC |
|
UL |
CSA |
CSA |
|
CCC |
CCC |
UL |
Standards |
UL 508 |
UL 508 |
EN/IEC 60947-5-1 |
|
EN/IEC 60204-1 |
EN/IEC 60204-1 |
UL 508 |
|
EN/IEC 60947-5-1 |
CSA C22.2 No 14 |
EN/IEC 60204-1 |
|
CSA C22.2 No 14 |
EN/IEC 60947-5-1 |
CSA C22.2 No 14 |
Packing Units |
Unit Type of Package 1 |
PCE |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
1 |
Package 1 Height |
3.3 cm |
3.4 cm |
3.3 cm |
Package 1 Width |
6.4 cm |
6.5 cm |
6.4 cm |
Package 1 Length |
9.8 cm |
10.0 cm |
9.8 cm |
Package 1 Weight |
95.0 g |
92.0 g |
88 g |
Unit Type of Package 2 |
S02 |
S02 |
S02 |
Number of Units in Package 2 |
58 |
50 |
58 |
Package 2 Height |
15.0 cm |
15.0 cm |
15 cm |
Package 2 Width |
30.0 cm |
30.0 cm |
30 cm |
Package 2 Length |
40.0 cm |
40.0 cm |
40 cm |
Package 2 Weight |
6.005 kg |
5.001 kg |
5.6 kg |
Contractual warranty |
Warranty |
18 months |
18 months |
18 months |