| Main information | 
| Part Number | XCKJ10541H29C | 
| Product Series | Telemecanique Limit switches XC Standard | 
| Serial Number | Standard type | 
| product type | Limit switch | 
| product short name | XCK | 
| sensor design |  | 
| ontology type | Fixed | 
| Control head type | Swivel head | 
| Material | Metal | 
| body material | Zamak | 
| head material | Zamak | 
| fixed mode | By ontology | 
| Operation head movement | To rotate | 
| Operating head type | Spring Return Roller Rocker Thermoplastic Variable Length | 
| method type | Side movement, 1 or 2 directions programmable | 
| cable entry hole | 1 cable gland for M20x1.6, outer cable diameter: 7…13 mm | 
| number of poles | 2 | 
| contact type | 1 NC + 1 NO | 
| contact action | Momentary | 
| Additional information | 
| switch trigger | 30° lip | 
| Electrical connections | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | 
| Type of contact wire insulation | Zb | 
| Step count | 1 | 
| force open | None | 
| Minimum trigger torque | 0.25 Nm | 
| force open minimum force |  | 
| Minimum trip force |  | 
| operating speed | 1.5 m/s | 
| Rated operating current [Ie] | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A | 
|  | 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A | 
| Conventional enclosed heating current [Ithe] | 10A | 
| Rated insulation voltage [Ui] | 300 V according to UL 508 | 
|  | 500 V (pollution degree 3) according to IEC 60947-1 | 
|  | 300 V according to CSA C22.2 No 14 | 
| maximum resistance across terminals | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60664 | 
|  | 6 kV according to IEC 60947-1 | 
| Short circuit protection | 10 A fuse fuse, type gG | 
| Electrical life | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C | 
|  | 5000000 cycles, DC-13, inductive load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C | 
|  | 5000000 cycles, DC-13, inductive loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | 
| Mechanical life | 30000000 times | 
| width | 40 mm | 
| high | 77 mm | 
| depth | 44 mm | 
| Product Weight | 0.485 kg | 
| ISO n°1 terminals | (13-14)NO | 
|  | (21-22)NC | 
| Environment | 
| impact resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 
| Anti-vibration | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 
| IP protection class | IP66 conforming to IEC 60529 | 
| IK protection class | IK07 conforms to EN 50102 | 
| Type of overvoltage | Class I conforms to IEC 61140 | 
|  | Class I conforms to NF C 20-030 | 
| operating temperature | -25…70°C | 
| storage environment temperature | -40…70°C | 
| Protective treatment | TH | 
| certified product | CCC | 
| Standards compliant | CSA C22.2 No 14 | 
|  | EN 60204-1 | 
|  | IEC 60947-5-1 | 
|  | EN 60947-5-1 | 
|  | CENELEC EN 50041 | 
|  | IEC 60204-1 | 
|  | UL 508 | 
| Packaging unit | 
| Unit Type of Package 1 | PCE | 
| Number of Units in Package 1 | 1 | 
| Package 1 Weight | 461.0g | 
| Package 1 Height | 4.155cm | 
| Package 1 Width | 6.88cm | 
| Package 1 Length | 12.865 cm | 
| Unit Type of Package 2 | S02 | 
| Number of Units in Package 2 | 30 | 
| Package 2 Weight | 14.561kg | 
| Package 2 Height | 15cm | 
| Package 2 Width | 30cm | 
| Package 2 Length | 40cm | 
| Unit Type of Package 3 | PAL | 
| Number of Units in Package 3 | 480 | 
| Package 3 Weight | 247.154kg | 
| Package 3 Height | 75cm | 
| Package 3 Width | 60cm | 
| Package 3 Length | 80cm | 
| contract warranty |  | 
| Warranty | 18 months |