| Main | 
| Part Number | XCKS149 | XCKS102 | XCKS101 | XCKS131 | 
| Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | 
| Series name | Standard format | Standard format | Standard type | Standard type | 
| Product or component type | Limit switch | Limit switch | Limit switch | Limit switch | 
| device short name | XCKS | XCKS | XCKS | XCKS | 
| Sensor design |  | Form C conforming to CENELEC EN 50041 | Type B conforms to CENELEC EN 50041 | Type A conforms to CENELEC EN 50041 | 
| body type | Fixed | Fixed | Fixed | Fixed | 
| Head type | Rotary head | Plunger head | Direct acting head | Swivel head | 
| Material | Plastic | Plastic | Plastic | Plastic | 
| Body material | Plastic | Plastic | Plastic | Plastic | 
| Head material | Plastic | Plastic | Plastic | Plastic | 
| Fixing mode | By the body | By the body | By ontology | By ontology | 
| Movement of operating head | Rotary | Linear | Linear | To rotate | 
| Type of operator | Spring return roller lever elastomer variable length, roller diameter 50 mm | Spring return roller plunger metal | Spring return direct acting metal | Spring Return Roller Rocker Thermoplastic | 
| Type of approach | Lateral approach, 1 or 2 programmable direction | Lateral approach, 2 directions | Vertical movement, one-way | Side movement, 1 or 2 directions programmable | 
| Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 
| Number of poles | 2 | 2 | 2 | 2 | 
| Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO | 
| Contact operation | Snap action | Snap action | Momentary | Momentary | 
| Complementary | 
| Switch actuation | By 30° cam | By 30° cam | The end | 30° lip | 
| Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | 
| Contacts insulation form | Zb | Zb | Zb | Zb | 
| Number of steps | 1 | 1 | 1 | 1 | 
| Positive opening | With | With | Have | Have | 
| Force open minimum torque |  |  |  | 0.15 Nm | 
| Minimum torque for tripping | 0.1 N.m |  |  | 0.1 Nm | 
| Minimum actuation speed | 0.01 m/min | 0.01 m/min | 0.01 m/min | 0.01 m/min | 
| Positive opening minimum force |  | 20 N | 30N |  | 
| Minimum force for tripping |  | 12 N | 15N |  | 
| Maximum actuation speed | 1.5 m/s | 0.5 m/s | 0.5 m/s | 1.5 m/s | 
| Repeatability |  |  | Trigger point is 0.05mm 1 million operating cycles |  | 
| Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | 
|  | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | 
| [Ithe] conventional enclosed thermal current | 10 A AC | 10 A AC | 10A AC | 10A AC | 
| [Ui] rated insulation voltage | 300 V conforming to UL 508 | 300 V conforming to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 | 
|  | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 
|  | 300 V conforming to CSA C22.2 No 14 | 300 V conforming to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 
| Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 6 kV conforming to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 | 
|  | 6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | 
| Short-circuit protection | 10 A cartridge fuse, type gG | 10 A cartridge fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG | 
| Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 
|  | 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 
|  | 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | 
| Mechanical durability | 20000000 cycles | 15000000 cycles | 25000000 times | 20000000 times | 
| Width | 50 mm | 40 mm | 40 mm | 40 mm | 
| Height | 133…188 mm | 117 mm | 104 mm | 130mm | 
| Depth | 65 mm | 37 mm | 37 mm | 60 mm | 
| Product weight | 0.18 kg | 0.133 kg | 0.125 kg | 0.16kg | 
| Terminals description ISO n°1 | (21-22)NC | (13-14)NO | (21-22)NC | (13-14)NO | 
|  | (13-14)NO | (21-22)NC | (13-14)NO | (21-22)NC | 
| Environment | 
| Shock resistance | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 
| Vibration resistance | 20 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 
| IP degree of protection | IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | IP67 conforms to screwed | IP67 conforms to screwed | 
|  | IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 | IP66 conforms to screwed | IP66 conforms to screwed | 
| IK degree of protection | IK05 conforming to EN 50102 | IK05 conforming to EN 50102 | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 | 
| Electrical shock protection class | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | 
|  | Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | 
| Overvoltage category | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | 
|  | Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | 
| Ambient air temperature for operation | -25…70 °C | -25…70 °C | -25…70°C | -25…70°C | 
| Ambient air temperature for storage | -40…70 °C | -40…70 °C | -40…70°C | -40…70°C | 
| Protective treatment | TC | TC | TC | TC | 
| Product certifications | CSA | UL | CCC | UL | 
|  | UL | CCC | UL | CSA | 
|  | CCC | CSA | CSA | CCC | 
| Standards | EN 60204-1 | UL 508 | EN 60947-5-1 | IEC 60947-5-1 | 
|  | IEC 60947-5-1 | IEC 60947-5-1 | UL 508 | EN 60947-5-1 | 
|  | UL 508 | CSA C22.2 No 14 | IEC 60204-1 | UL 508 | 
|  | IEC 60204-1 | CENELEC EN 50041 | CSA C22.2 No 14 | CSA C22.2 No 14 | 
|  | CENELEC EN 50041 | EN 60947-5-1 | CENELEC EN 50041 | CENELEC EN 50041 | 
|  | CSA C22.2 No 14 | EN 60204-1 | EN 60204-1 | IEC 60204-1 | 
|  | EN 60947-5-1 | IEC 60204-1 | IEC 60947-5-1 | EN 60204-1 | 
| Packing Units | 
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 5.000 cm | 4.0 cm | 4cm | 4.2 cm | 
| Package 1 Width | 9.000 cm | 6.0 cm | 6cm | 9.6cm | 
| Package 1 Length | 15.300 cm | 13.5 cm | 13.2 cm | 13.2 cm | 
| Package 1 Weight | 214.000 g | 150.0 g | 144g | 176.0g | 
| Unit Type of Package 2 | S02 | S02 | S02 | S02 | 
| Number of Units in Package 2 | 12 | 36 | 36 | Twenty two | 
| Package 2 Height | 15.000 cm | 15.0 cm | 15cm | 15.0cm | 
| Package 2 Width | 30.000 cm | 30.0 cm | 30cm | 30.0cm | 
| Package 2 Length | 40.000 cm | 40.0 cm | 40cm | 40.0cm | 
| Package 2 Weight | 3.010 kg | 5.923 kg | 5.603 kg | 4.364 kg | 
| Contractual warranty | 
| Warranty | 18 months | 18 months | 18 months | 18 months |