| Main |
| Part Number |
XCKS149 |
XCKS102 |
XCKS101 |
XCKS131 |
| Range of product |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
| Series name |
Standard format |
Standard format |
Standard type |
Standard type |
| Product or component type |
Limit switch |
Limit switch |
Limit switch |
Limit switch |
| device short name |
XCKS |
XCKS |
XCKS |
XCKS |
| Sensor design |
|
Form C conforming to CENELEC EN 50041 |
Type B conforms to CENELEC EN 50041 |
Type A conforms to CENELEC EN 50041 |
| body type |
Fixed |
Fixed |
Fixed |
Fixed |
| Head type |
Rotary head |
Plunger head |
Direct acting head |
Swivel head |
| Material |
Plastic |
Plastic |
Plastic |
Plastic |
| Body material |
Plastic |
Plastic |
Plastic |
Plastic |
| Head material |
Plastic |
Plastic |
Plastic |
Plastic |
| Fixing mode |
By the body |
By the body |
By ontology |
By ontology |
| Movement of operating head |
Rotary |
Linear |
Linear |
To rotate |
| Type of operator |
Spring return roller lever elastomer variable length, roller diameter 50 mm |
Spring return roller plunger metal |
Spring return direct acting metal |
Spring Return Roller Rocker Thermoplastic |
| Type of approach |
Lateral approach, 1 or 2 programmable direction |
Lateral approach, 2 directions |
Vertical movement, one-way |
Side movement, 1 or 2 directions programmable |
| Cable entry |
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm |
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm |
1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
| Number of poles |
2 |
2 |
2 |
2 |
| Contacts type and composition |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
| Contact operation |
Snap action |
Snap action |
Momentary |
Momentary |
| Complementary |
| Switch actuation |
By 30° cam |
By 30° cam |
The end |
30° lip |
| Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
| Contacts insulation form |
Zb |
Zb |
Zb |
Zb |
| Number of steps |
1 |
1 |
1 |
1 |
| Positive opening |
With |
With |
Have |
Have |
| Force open minimum torque |
|
|
|
0.15 Nm |
| Minimum torque for tripping |
0.1 N.m |
|
|
0.1 Nm |
| Minimum actuation speed |
0.01 m/min |
0.01 m/min |
0.01 m/min |
0.01 m/min |
| Positive opening minimum force |
|
20 N |
30N |
|
| Minimum force for tripping |
|
12 N |
15N |
|
| Maximum actuation speed |
1.5 m/s |
0.5 m/s |
0.5 m/s |
1.5 m/s |
| Repeatability |
|
|
Trigger point is 0.05mm 1 million operating cycles |
|
| Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
|
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A |
| [Ithe] conventional enclosed thermal current |
10 A AC |
10 A AC |
10A AC |
10A AC |
| [Ui] rated insulation voltage |
300 V conforming to UL 508 |
300 V conforming to UL 508 |
300 V according to UL 508 |
300 V according to UL 508 |
|
500 V (pollution degree 3) conforming to IEC 60947-1 |
500 V (pollution degree 3) conforming to IEC 60947-1 |
500 V (pollution degree 3) according to IEC 60947-1 |
500 V (pollution degree 3) according to IEC 60947-1 |
|
300 V conforming to CSA C22.2 No 14 |
300 V conforming to CSA C22.2 No 14 |
300 V according to CSA C22.2 No 14 |
300 V according to CSA C22.2 No 14 |
| Maximum resistance across terminals |
25 MOhm conforming to IEC 60255-7 category 3 |
25 MOhm conforming to IEC 60255-7 category 3 |
25 MΩ conforming to IEC 60255-7 Safety Class 3 |
25 MΩ conforming to IEC 60255-7 Safety Class 3 |
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 |
6 kV conforming to IEC 60664 |
6 kV according to IEC 60664 |
6 kV according to IEC 60664 |
|
6 kV conforming to IEC 60947-1 |
6 kV conforming to IEC 60947-1 |
6 kV according to IEC 60947-1 |
6 kV according to IEC 60947-1 |
| Short-circuit protection |
10 A cartridge fuse, type gG |
10 A cartridge fuse, type gG |
10 A fuse fuse, type gG |
10 A fuse fuse, type gG |
| Electrical durability |
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
|
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
|
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C |
loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C |
| Mechanical durability |
20000000 cycles |
15000000 cycles |
25000000 times |
20000000 times |
| Width |
50 mm |
40 mm |
40 mm |
40 mm |
| Height |
133…188 mm |
117 mm |
104 mm |
130mm |
| Depth |
65 mm |
37 mm |
37 mm |
60 mm |
| Product weight |
0.18 kg |
0.133 kg |
0.125 kg |
0.16kg |
| Terminals description ISO n°1 |
(21-22)NC |
(13-14)NO |
(21-22)NC |
(13-14)NO |
|
(13-14)NO |
(21-22)NC |
(13-14)NO |
(21-22)NC |
| Environment |
| Shock resistance |
40 gn for 11 ms conforming to IEC 60068-2-27 |
40 gn for 11 ms conforming to IEC 60068-2-27 |
40 gn for 11 ms conforming to IEC 60068-2-27 |
40 gn for 11 ms conforming to IEC 60068-2-27 |
| Vibration resistance |
20 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection |
IP67 conforming to IEC 60529 |
IP67 conforming to IEC 60529 |
IP67 conforms to screwed |
IP67 conforms to screwed |
|
IP66 conforming to IEC 60529 |
IP66 conforming to IEC 60529 |
IP66 conforms to screwed |
IP66 conforms to screwed |
| IK degree of protection |
IK05 conforming to EN 50102 |
IK05 conforming to EN 50102 |
IK05 conforms to EN 50102 |
IK05 conforms to EN 50102 |
| Electrical shock protection class |
Class II conforming to IEC 61140 |
Class II conforming to IEC 61140 |
Class II conforms to IEC 61140 |
Class II conforms to IEC 61140 |
|
Class II conforming to NF C 20-030 |
Class II conforming to NF C 20-030 |
Class II conforms to NF C 20-030 |
Class II conforms to NF C 20-030 |
| Overvoltage category |
Class II conforming to IEC 61140 |
Class II conforming to IEC 61140 |
Class II conforms to IEC 61140 |
Class II conforms to IEC 61140 |
|
Class II conforming to NF C 20-030 |
Class II conforming to NF C 20-030 |
Class II conforms to NF C 20-030 |
Class II conforms to NF C 20-030 |
| Ambient air temperature for operation |
-25…70 °C |
-25…70 °C |
-25…70°C |
-25…70°C |
| Ambient air temperature for storage |
-40…70 °C |
-40…70 °C |
-40…70°C |
-40…70°C |
| Protective treatment |
TC |
TC |
TC |
TC |
| Product certifications |
CSA |
UL |
CCC |
UL |
|
UL |
CCC |
UL |
CSA |
|
CCC |
CSA |
CSA |
CCC |
| Standards |
EN 60204-1 |
UL 508 |
EN 60947-5-1 |
IEC 60947-5-1 |
|
IEC 60947-5-1 |
IEC 60947-5-1 |
UL 508 |
EN 60947-5-1 |
|
UL 508 |
CSA C22.2 No 14 |
IEC 60204-1 |
UL 508 |
|
IEC 60204-1 |
CENELEC EN 50041 |
CSA C22.2 No 14 |
CSA C22.2 No 14 |
|
CENELEC EN 50041 |
EN 60947-5-1 |
CENELEC EN 50041 |
CENELEC EN 50041 |
|
CSA C22.2 No 14 |
EN 60204-1 |
EN 60204-1 |
IEC 60204-1 |
|
EN 60947-5-1 |
IEC 60204-1 |
IEC 60947-5-1 |
EN 60204-1 |
| Packing Units |
| Unit Type of Package 1 |
PCE |
PCE |
PCE |
PCE |
| Number of Units in Package 1 |
1 |
1 |
1 |
1 |
| Package 1 Height |
5.000 cm |
4.0 cm |
4cm |
4.2 cm |
| Package 1 Width |
9.000 cm |
6.0 cm |
6cm |
9.6cm |
| Package 1 Length |
15.300 cm |
13.5 cm |
13.2 cm |
13.2 cm |
| Package 1 Weight |
214.000 g |
150.0 g |
144g |
176.0g |
| Unit Type of Package 2 |
S02 |
S02 |
S02 |
S02 |
| Number of Units in Package 2 |
12 |
36 |
36 |
Twenty two |
| Package 2 Height |
15.000 cm |
15.0 cm |
15cm |
15.0cm |
| Package 2 Width |
30.000 cm |
30.0 cm |
30cm |
30.0cm |
| Package 2 Length |
40.000 cm |
40.0 cm |
40cm |
40.0cm |
| Package 2 Weight |
3.010 kg |
5.923 kg |
5.603 kg |
4.364 kg |
| Contractual warranty |
| Warranty |
18 months |
18 months |
18 months |
18 months |