Mean Well Power Switch Mode Power Supply-50W Output
LRS-50 series is a 50W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-50 that the whole series operates from -30℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.2W), it allows the end system to easily meet the worldwide energy requirement. LRS-50 has the complete protection functions and 5G anti- vibration capability; it is complied with the international safety regulations such as TUV EN62368-1, EN 60335 – 1 , EN 61558 – 1 / – 2 – 16 , UL 62368 – 1 and GB 4943 . LRS- 50 series serves as a high price- to- performance power supply solution for various industrial applications.
Features :
‧Universal AC input / Full range
‧Withstand 300VAC surge input for 5 second
‧No load power consumption<0.2W
‧Miniature size and 1U low profile
‧High operating temperature up to 70℃
‧Protections: Short circuit / Overload / Over voltage
‧Cooling by free air convection
‧Compliance to IEC/EN 60335-1(PD3) and IEC/EN61558-1, -2-16 for household appliances
‧Operating altitude up to 5000 meters (Note.8)
‧Withstand 5G vibration test
‧High efficiency, long life and high reliability
‧LED indicator for power on
‧Over voltage category Ⅲ
‧100% full load burn-in test
SPECIFICATION
MODEL | LRS-50-3.3 | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 10A | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 10A | 0 ~ 4.2A | 0 ~ 3.4A | 0 ~ 2.2A | 0 ~ 1.45A | 0 ~ 1.1A | |
RATED POWER | 33W | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT |
VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 80% | 83% | 86% | 88% | 88% | 89% | 90% | |
AC CURRENT (Typ.) | 0.95A/115VAC 0.56A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION |
OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.9~ 7.3V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
SAFETY & EMC (Note 9) |
SAFETY STANDARDS | UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020, KC KN32,KN35(for LRS-50-12/24 only) | |||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020, KC KN32,KN35(for LRS-50-12/24 only) | |||||||
OTHERS |
MTBF | 645K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 99*82*30mm (L*W*H) | |||||||
PACKING | 0.23Kg; 60pcs/14.8Kg/0.88CUFT | |||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. 3.3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. 8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. |