SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1045666
Magnetic Cylinder Model: MPS-032TSTP0
OEM Spec Ref
Features
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Cylinder type | T-slot | ||||
Cylinder types with adapter | Round body cylinder
Profile cylinders and tie-rod cylinders Dovetail groove cylinder SMC rail CDQ2 SMC rail ECDQ2 SMC cylinders with C-slot |
||||
Measuring range | 32 mm 1) | ||||
Housing length | 45 mm | ||||
Output function | Analog | ||||
Electrical wiring | DC 4-wire | ||||
Analog output (voltage) | 0 V … 10 V 2) | ||||
Analog output (current) | 4 mA … 20 mA 2) | ||||
Teach-in | ✔ | ||||
Enclosure rating | IP67 3) | ||||
|
[/fusion_table]
- 1) , ± 1 mm.
- 2) The sensor only activates the wired output.
- 3) According to EN 60529.
Mechanics/electronics
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Supply voltage | 15 V DC … 30 V DC | ||||||||||||||
Power consumption | 22 mA 1) | ||||||||||||||
Max. load resistance | ≤ 500 Ω Power Output, at 24 V | ||||||||||||||
Min. load resistance | ≥ 2 kΩ 2) | ||||||||||||||
Protection class | III | ||||||||||||||
Time delay before availability | 1.5 s | ||||||||||||||
Required magnetic field sensitivity, typ. | 4 mT … 30 mT | ||||||||||||||
Resolution, typ. | 0.03 % FSR (max. ≥ 0.05 mm) 3) | ||||||||||||||
Linearity error, typ. | 0.3 mm 4) | ||||||||||||||
Repeat accuracy, typ. | 0.06 % FSR (≥ 0.1 mm) 5) | ||||||||||||||
Sampling rate, typ. | 1 ms 6) | ||||||||||||||
Status indicator LED | ✔ | ||||||||||||||
Reverse polarity protection | ✔ | ||||||||||||||
Short-circuit protection | ✔ | ||||||||||||||
Ambient operating temperature | –20 °C … +70 °C | ||||||||||||||
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm | ||||||||||||||
EMC | According to EN 60947-5-2 7) | ||||||||||||||
Connection type | Cable with M8 male connector, 4-pin, 0.3 m | ||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
UL File No. | NRKH.E181493 & NRKH7.E181493 |
[/fusion_table]
- 1) Without load.
- 2) Voltage output.
- 3) FSR: Full Scale Range; max. measuring range.
- 4) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.
- 5) At 25 ° C, repeatability magnet movement in one direction.
- 6) Only in standard mode, not in IO-Link mode.
- 7) The analog measured value can deviate under transient conditions.
Safety-related parameters
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
MTTFD | 387 years |
DCavg | 0 % |
[/fusion_table]