Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Product number A9N22420 A9N22421 A9N22422 A9N22423
Product family Multi9 Multi9 Multi9 Multi9
Product family Multi 9 Multi 9 Multi 9 Multi 9
Product name C65-DC C65-DC C65-DC C65-DC
Product type Small circuit breakers Small circuit breakers Small circuit breakers Small circuit breakers
Short name of the product C65N-DC C65N-DC C65N-DC C65N-DC
Product application Distribution protection Distribution protection Distribution protection Distribution protection
Number of poles 2P 2P 2P 2P
Number of protection poles 2 2 2 2
Rated current [In] 1 A in… Up to 40 °C 2 A in… Up to 40 °C 4 A in… Up to 40 °C 6 A in… Up to 40 °C
Network type DC DC DC DC
Trip type Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic
Trip curve C C C C
Breaking ability 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2
Supplemental Information
Rated operating voltage [UE] 126 V DC 126 V DC 126 V DC 126 V DC
Magnetic trip restrictions 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 %
Using Breaking Capability [ICS] 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC
Current limit level 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2
Rated impulse withstand voltage [UIMP] 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2
Width (multiple of 9mm) 4 4 4 4
height 84 mm 84 mm 84 mm 84 mm
width 36 mm 36 mm 36 mm 36 mm
depth 73.5 mm 73.5 mm 73.5 mm 73.5 mm
Product net weight 220 g 220 g 220 g 220 g
Mechanical life 20000 times 20000 times 20000 times 20000 times
Electrical life 10000 times 10000 times 10000 times 10000 times
Wiring capability Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm²
Tightening torque 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit:
Leakage current protection No leakage protection No leakage protection No leakage protection No leakage protection
environment
Compliance with standards GB 14048.2 IEC 60947-2 GB 14048.2 IEC 60947-2
IEC 60947-2 GB 14048.2 IEC 60947-2 GB 14048.2
Product certification CCC CCC CCC CCC
IEC CB report IEC CB report IEC CB report IEC CB report
Resistance to humidity and heat 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1
relative humidity 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C
Operating temperature -30… 70 °C -30… 70 °C -30… 70 °C -30… 70 °C
Storage ambient temperature -40… 85 °C -40… 85 °C -40… 85 °C -40… 85 °C
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 3.509 cm 3.513 cm 3.522 cm 3.6 cm
Package 1 Width 7.378 cm 7.4 cm 7.4 cm 7.3 cm
Package 1 Length 8.38 cm 8.336 cm 8.346 cm 8.4 cm
Package 1 Weight 219.7 g 214.1 g 213.5 g 208 g
Unit Type of Package 2 BB1 BB1 BB1 BB1
Number of Units in Package 2 6 6 6 6
Package 2 Height 7.818 cm 8.128 cm 8.264 cm 8.048 cm
Package 2 Width 8.803 cm 8.925 cm 9.024 cm 8.968 cm
Package 2 Length 21.963 cm 22.211 cm 22.184 cm 22.092 cm
Package 2 Weight 1.367 kg 1.33 kg 1.326 kg 1.297 kg
Unit Type of Package 3 CAR CAR CAR CAR
Number of Units in Package 3 48 48 48 48
Package 3 Height 19.315 cm 19.6 cm 19.5 cm 19.5 cm
Package 3 Width 30.015 cm 30 cm 29.8 cm 29.5 cm
Package 3 Length 39 cm 39.5 cm 39.6 cm 39.5 cm
Package 3 Weight 11.5 kg 11 kg 11 kg 11 kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Product number A9N22424 A9N22425 A9N22426 A9N22427
Product family Multi9 Multi9 Multi9 Multi9
Product family Multi 9 Multi 9 Multi 9 Multi 9
Product name C65-DC C65-DC C65-DC C65-DC
Product type Small circuit breakers Small circuit breakers Small circuit breakers Small circuit breakers
Short name of the product C65N-DC C65N-DC C65N-DC C65N-DC
Product application Distribution protection Distribution protection Distribution protection Distribution protection
Number of poles 2P 2P 2P 2P
Number of protection poles 2 2 2 2
Rated current [In] 10 A in… Up to 40 °C 16 A in… Up to 40 °C 20 A in… Up to 40 °C 25 A in… Up to 40 °C
Network type DC DC DC DC
Trip type Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic
Trip curve C C C C
Breaking ability 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2
Supplemental Information
Rated operating voltage [UE] 126 V DC 126 V DC 126 V DC 126 V DC
Magnetic trip restrictions 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 %
Using Breaking Capability [ICS] 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC
Current limit level 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2
Rated impulse withstand voltage [UIMP] 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2
Width (multiple of 9mm) 4 4 4 4
height 84 mm 84 mm 84 mm 84 mm
width 36 mm 36 mm 36 mm 36 mm
depth 73.5 mm 73.5 mm 73.5 mm 73.5 mm
Product net weight 220 g 220 g 220 g 220 g
Mechanical life 20000 times 20000 times 20000 times 20000 times
Electrical life 10000 times 10000 times 10000 times 10000 times
Wiring capability Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…25 mm²
Tightening torque 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit: 2.5 N.m upper or lower wiring Power circuit:
Leakage current protection No leakage protection No leakage protection No leakage protection No leakage protection
environment
Compliance with standards IEC 60947-2 GB 14048.2 IEC 60947-2 GB 14048.2
GB 14048.2 IEC 60947-2 GB 14048.2 IEC 60947-2
Product certification CCC CCC CCC CCC
IEC CB report IEC CB report IEC CB report IEC CB report
Resistance to humidity and heat 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1
relative humidity 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C
Operating temperature -30… 70 °C -30… 70 °C -30… 70 °C -30… 70 °C
Storage ambient temperature -40… 85 °C -40… 85 °C -40… 85 °C -40… 85 °C
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 3.537 cm 3.6 cm 3.544 cm 3.542 cm
Package 1 Width 7.411 cm 7.3 cm 7.412 cm 7.356 cm
Package 1 Length 8.367 cm 8.4 cm 8.369 cm 8.354 cm
Package 1 Weight 207 g 206 g 213 g 216.6 g
Unit Type of Package 2 BB1 BB1 BB1 BB1
Number of Units in Package 2 6 6 6 6
Package 2 Height 8.5 cm 8.5 cm 8.4 cm 7.847 cm
Package 2 Width 8.9 cm 8.9 cm 9.1 cm 9.018 cm
Package 2 Length 22 cm 22.2 cm 21.8 cm 22.223 cm
Package 2 Weight 1.284 kg 1.312 kg 1.321 kg 1.351 kg
Unit Type of Package 3 CAR CAR CAR CAR
Number of Units in Package 3 48 48 48 48
Package 3 Height 19.8 cm 19.7 cm 19.5 cm 19.8 cm
Package 3 Width 29.3 cm 29.2 cm 29.5 cm 29.7 cm
Package 3 Length 39.1 cm 39.8 cm 38.8 cm 40 cm
Package 3 Weight 10.697 kg 10.887 kg 11.02 kg 11 kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Product number A9N22428 A9N22429 A9N22430 A9N22431
Product family Multi9 Multi9 Multi9 Multi9
Product family Multi 9 Multi 9 Multi 9 Multi 9
Product name C65-DC C65-DC C65-DC C65-DC
Product type Small circuit breakers Small circuit breakers Small circuit breakers Small circuit breakers
Short name of the product C65N-DC C65N-DC C65N-DC C65N-DC
Product application Distribution protection Distribution protection Distribution protection Distribution protection
Number of poles 2P 2P 2P 2P
Number of protection poles 2 2 2 2
Rated current [In] 32 A in… Up to 40 °C 40 A in… Up to 40 °C 50 A in… Up to 40 °C 63 A in… Up to 40 °C
Network type DC DC DC DC
Trip type Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic
Trip curve C C C C
Breaking ability 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2
Supplemental Information
Rated operating voltage [UE] 126 V DC 126 V DC 126 V DC 126 V DC
Magnetic trip restrictions 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 % 8.5 x In +/- 20 %
Using Breaking Capability [ICS] 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC 6 kA 100 % according to IEC 60947-2 – 126 V DC
Current limit level 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2 3 Complies with IEC 60947-2
Rated impulse withstand voltage [UIMP] 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2 6 kV according to IEC 60947-2
Width (multiple of 9mm) 4 4 4 4
height 84 mm 84 mm 84 mm 84 mm
width 36 mm 36 mm 36 mm 36 mm
depth 73.5 mm 73.5 mm 73.5 mm 73.5 mm
Product net weight 220 g 220 g 220 g 220 g
Mechanical life 20000 times 20000 times 20000 times 20000 times
Electrical life 10000 times 10000 times 10000 times 10000 times
Wiring capability Tunnel terminals (upper or lower wiring) – 1…25 mm² Tunnel terminals (upper or lower wiring) – 1…35 mm² Tunnel terminals (upper or lower wiring) – 1…35 mm² Tunnel terminals (upper or lower wiring) – 1…35 mm²
Tightening torque 3.5 N.m upper or lower wiring Power circuit: 3.5 N.m upper or lower wiring Power circuit: 3.5 N.m upper or lower wiring Power circuit: 3.5 N.m upper or lower wiring Power circuit:
Leakage current protection No leakage protection No leakage protection No leakage protection No leakage protection
environment
Compliance with standards IEC 60947-2 IEC 60947-2 GB 14048.2 GB 14048.2
GB 14048.2 GB 14048.2 IEC 60947-2 IEC 60947-2
Product certification IEC CB reports CCC IEC CB reports CCC
CCC IEC CB report CCC IEC CB report
Resistance to humidity and heat 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1 2 Complies with IEC 60068-1
relative humidity 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C 95 % in… Up to 55 °C
Operating temperature -30… 70 °C -30… 70 °C -30… 70 °C -30… 70 °C
Storage ambient temperature -40… 85 °C -40… 85 °C -40… 85 °C -40… 85 °C
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 7.36 cm 3.52 cm 8 cm 3.525 cm
Package 1 Width 8.36 cm 7.324 cm 3.7 cm 7.394 cm
Package 1 Length 3.54 cm 8.348 cm 9 cm 8.324 cm
Package 1 Weight 225 g 234.3 g 241.3 g 240.6 g
Unit Type of Package 2 BB1 BB1 BB1 BB1
Number of Units in Package 2 6 6 6 6
Package 2 Height 8.4 cm 8.067 cm 22.2 cm 7.965 cm
Package 2 Width 9.5 cm 8.957 cm 8.2 cm 8.837 cm
Package 2 Length 22.4 cm 22.292 cm 9.2 cm 22.056 cm
Package 2 Weight 1.383 kg 1.452 kg 1.49 kg 1.493 kg
Unit Type of Package 3 CAR CAR CAR CAR
Number of Units in Package 3 48 48 48 48
Package 3 Height 20 cm 19.6 cm 19.4 cm 19.13 cm
Package 3 Width 29.5 cm 30 cm 30 cm 29.717 cm
Package 3 Length 39.6 cm 39.5 cm 40 cm 39.8 cm
Package 3 Weight 11.534 kg 12 kg 12.46 kg 12.5 kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

 

Weight N/A
Dimensions N/A