SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1059735
Magnetic Cylinder Model: MZC1-2V2PS-KP0
OEM Spec Ref 

Features

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Cylinder type C-slot
Cylinder types with adapter SMC rail CDQ2

SMC rail ECDQ2

Round body cylinder

Profile cylinders and tie-rod cylinders

Housing length 23.7 mm
Switching output PNP
Switching frequency 1,000 Hz
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP68 1)

[/fusion_table]

  • 1) According to EN 60529 (IP 67 / IP 68).

Mechanics/electronics

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Supply voltage 10 V DC … 30 V DC
Power consumption 8 mA 1)
Voltage drop ≤ 2.5 V
Continuous current Ia ≤ 100 mA
Protection class III
Response sensitivity, typ. 2.2 mT
Overrun distance, typ. 4 mm
Hysteresis, typ. ≤ 0.8 mT
Reproducibility ≤ 0.1 mT 2)
Reverse polarity protection
Short-circuit protection
Power-up pulse protection
Ambient operating temperature –30 °C … +80 °C
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
EMC According to EN 60947-5-2
Connection type Cable with connector M8, 3-pin, drag chain use, 0.3 m
Connection type Detail
Conductor cross-section 0.09 mm²
Cable diameter Ø 2.2 mm
Bending radius With fixed installation > 2 x cable diameter
For flexible use > 5 x cable diameter
Torsion force ± 270° / 0.1 m
Torsion cycles 300,000
Drag chain cycles 5,000,000
Drag chain parameters Traversing speed max. 3 m/s
Acceleration max. 10 m/s²
Bending cycles in the drag chain min. 5 million
Cable outlet Axial
Material
Housing Plastic
Cable PUR
UL File No. NRKH.E181493 & NRKH7.E181493

[/fusion_table]

  • 1) Without load.
  • 2) Ub and Ta constant.

Safety-related parameters

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

MTTFD 2,461 years
DCavg 0 %
TM (mission time) 20 years

[/fusion_table]