| General specifications | 
| Switching function | complementary | 
| Output type | PNP | 
| Rated operating distance | 20 mm | 
| Installation | flush | 
| Output polarity | DC | 
| Assured operating distance | 0 … 16.2 mm | 
| Actual operating distance | 18 … 22 mm | 
| Reduction factor rAl | 0.33 | 
| Reduction factor rCu | 0.31 | 
| Reduction factor r304 | 0.74 | 
| Reduction factor rBrass | 0.41 | 
| Output type | 4-wire | 
| Nominal ratings | 
| Operating voltage | 10 … 30 V DC | 
| Switching frequency | 0 … 440 Hz | 
| Hysteresis | typ. 5 % | 
| Reverse polarity protection | reverse polarity protected | 
| Short-circuit protection | pulsing | 
| Voltage drop | ≤ 2 V | 
| Operating current | 0 … 200 mA | 
| Off-state current | 0 … 0.5 mA | 
| No-load supply current | ≤ 20 mA | 
| Time delay before availability | 80 ms | 
| Operating voltage indicator | LED, green | 
| Switching state indicator | LED, yellow | 
| Functional safety related parameters | 
| MTTFd | 1289 a | 
| Mission Time (TM) | 20 a | 
| Diagnostic Coverage (DC) | 0 % | 
| Compliance with standards and directives | 
| Standard conformity |  | 
|  | Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012
 IEC 60947-5-2:2007
 IEC 60947-5-2 AMD 1:2012
 | 
| Approvals and certificates | 
| Protection class | II | 
|  | Rated insulation voltage | 253 V | 
|  | Rated impulse withstand voltage | 4000 V | 
| UL approval | cULus Listed, General Purpose | 
| CCC approval | CCC approval / marking not required for products rated ≤36 V | 
| Ambient conditions | 
| Ambient temperature | -25 … 85 °C (-13 … 185 °F) | 
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | 
| Mechanical specifications | 
| Connection type | Connector plug M12 x 1 , 4-pin | 
| Housing material | PA | 
| Sensing face | PA | 
| Degree of protection | IP68 / IP69K | 
| Cable |  | 
|  | Cable diameter | 3.3 mm ± 0.15 mm | 
| Mass | 130 g |