General specifications |
Switching function |
Normally closed (NC) |
Output type |
NAMUR |
Rated operating distance |
40 mm |
Installation |
non-flush |
Assured operating distance |
0 … 32.4 mm |
Actual operating distance |
36 … 44 mm |
Reduction factor rAl |
0.31 |
Reduction factor rCu |
0.3 |
Reduction factor r304 |
0.74 |
Nominal ratings |
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
Switching frequency |
0 … 150 Hz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
yes |
Current consumption |
|
|
Measuring plate not detected |
≥ 2.2 mA |
|
Measuring plate detected |
≤ 1 mA |
Switching state indicator |
LED, yellow |
Functional safety related parameters |
Safety Integrity Level (SIL) |
SIL 2 |
MTTFd |
1670 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Compliance with standards and directives |
Standard conformity |
|
|
Standards |
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates |
IECEx approval |
|
|
Equipment protection level Ga |
IECEx PTB 11.0021X |
|
Equipment protection level Gb |
IECEx PTB 11.0021X |
|
Equipment protection level Da |
IECEx PTB 11.0021X |
|
Equipment protection level Dc (tc) |
IECEx TUR 21.0020X |
|
Equipment protection level Mb |
IECEx PTB 11.0021X |
ATEX approval |
|
|
Equipment protection level Ga |
PTB 00 ATEX 2032 X |
|
Equipment protection level Gb |
PTB 00 ATEX 2032 X |
|
Equipment protection level Da |
PTB 00 ATEX 2032 X |
|
Equipment protection level Dc (tc) |
TÜV 20 ATEX 8526 X |
Protection class |
II |
|
Rated insulation voltage |
253 V |
|
Rated impulse withstand voltage |
4000 V |
UL approval |
|
|
Ordinary Location |
E87056 |
|
Hazardous Location |
E501628 |
|
Control drawing |
116-0451 |
CCC approval |
|
|
Hazardous Location |
2020322315002302 |
NEPSI approval |
|
|
NEPSI certificate |
GYJ16.1394X |
CML approval |
on request |
ANZEx |
19.3001X |
Marine approval |
DNVGL TAA00001A5 |
Ambient conditions |
Ambient temperature |
-25 … 100 °C (-13 … 212 °F) |
Storage temperature |
-40 … 100 °C (-40 … 212 °F) |
Mechanical specifications |
Connection type |
Connector plug |
Housing material |
PA |
Sensing face |
PA |
Degree of protection |
IP69K |
Connector |
|
|
Threading |
M12 x 1 |
|
Number of pins |
4 |
Mass |
130 g |
General information |
Use in the hazardous area |
see instruction manuals |