| Sensing method | Through-beam | Retro-reflective (with M.S.R. function) *1
 | Diffuse reflective | 
| Model | Horizontal E3S-CT11(-M1J) | Horizontal E3S-CR 11(-M1J) | Horizontal E3S-CD11(-M1J) | Horizontal E3S-CD12(-M1J) | 
| Vertical E3S-CT61(-M1J) | Vertical E3S-CR 61(-M1J) | Vertical E3S-CD61(-M1J) | Vertical E3S-CD62(-M1J) | 
| Sensing distance | 30 m | 3 m (when using E39-R1) | 700 mm (300 × 300 mm white paper)
 | 2 m (300 × 300 mm white paper)
 | 
| Standard sensing object | Opaque, 15-mm dia. min. | Opaque, 75-mm dia. min. | — | 
| Differential travel | — | 20% max. of sensing distance | 
| Directional angle | Emitter and Receiver: 3° to15°
 | 3° to 10° | — | 
| Light source (wavelength)
 | Infrared LED (880 nm) | Red LED (700 nm) | Infrared LED (880 nm) | 
| Power supply voltage
 | 10 to 30 VDC including 10% (p.p) ripple | 
| Current consumption
 | 50 mA max. (Emitter 25 mA max.
 Receiver 25 mA max.)
 | 40 mA max. | 
| Control output | Load power supply voltage: 30 VDC max. Load current: 100 mA max. (Residual voltage: NPN output: 1.2 V max., PNP output: 2.0 V max.)
 Open controller output (NPN/PNP selectable)
 Light-ON/Dark-ON selectable
 | 
| Protection circuits
 | Power supply reverse polarity
 circuit protection,
 Output short-
 circuit protection
 | Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention | 
| Response time | Operate or reset: 1 ms max. | Operate or reset 2 ms max. | 
| Sensitivity adjustment
 | One-turn adjuster | Two-turn endless adjuster with an indicator | 
| Ambient illumination
 (Receiver side)
 | Incandescent lamp: 5,000 lx max. Sunlight: 10,000 lx max.
 | 
| Ambient temperature range
 | Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) | 
| Ambient humidity range
 | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | 
| Insulation resistance
 | 20 MΩ min. (at 500 VDC) | 
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | 
| Vibration resistance | Destruction: 10 to 2,000 Hz, 1.5-mm double amplitude or 300 m/s2 for 0.5 hours each in X, Y, and Z directions | 
| Shock resistance | Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions | 
| Degree of protection | IEC60529: IP67 (in-house standards: oil-resistant), NEMA: 6P (indoors only) *2 | 
| Connection method | Pre-wired (standard cable length: 2 m) or Pre-wired M12 Connector (standard cable length: 0.3 m) | 
| Weight (packed state)
 | Approx. 270 g (Pre-wired cable)
 Approx. 230 g
 (Pre-wired Connector (M12))
 | Approx. 160 g (Pre-wired cable)
 Approx. 130 g
 (Pre-wired Connector (M12))
 | Approx. 150 g (Pre-wired cable)
 Approx. 110 g
 (Pre-wired Connector (M12))
 | 
| Material | Case | Zinc die-cast | 
| Operation panel cover
 | PES (polyether sulfone) | 
| Lens | Methacrylic resin | 
| Mounting Bracket
 | Stainless steel (SUS304) | 
| Accessories | Mounting Bracket (with screws), Adjustment screwdriver, Instruction manual, and Reflector (only for Retro-reflective Sensors) |