Specifications
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main information | ||
XCSD3719P20 | XCSD3902P20 | |
Product Series | Telemecanique Safety switches XCS | Telemecanique Safety switches XCS |
product type | Safety limit switch | Safety limit switch |
component name | XCSD | XCSD |
design | Compact | Compact |
Material | Metal | Metal |
Control head type | Swivel head | Direct acting head |
protection technology | Protective plastic cover, secured with 5 leaf-shaped hexagonal security screws | Protective plastic cover, secured with 5 leaf-shaped hexagonal security screws |
operator type | Steel Roller Rocker | Steel roller direct acting |
Contact type and composition | 1 NC + 1 NC + 1 NO | 1 NC + 1 NC + 1 NO |
contact action | Slow break, break before make | Momentary |
cable entry hole | 1 The cable entry with hole is suitable for M20 x 1.5 | 1 The cable entry with hole is suitable for M20 x 1.5 |
Additional information | ||
Electrical connections | Terminal | Terminal |
locking force | 1 x 0.34…2 x 0.75 mm² | 1 x 0.34…2 x 0.75 mm² |
switch trigger | 30° lip | 30° lip |
number of poles | 3 | 3 |
force open | With NC contact | With NC contact |
Mechanical life | 10000000 times | 10000000 times |
Minimum trigger torque | 0.1 Nm | 12N |
Force open minimum torque | 0.25 Nm | 36 N |
operating speed | 1.5 m/s | 0.5 m/s |
Contact wire regulation grade | B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 Annex A | B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 Annex A |
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5 -1 Appendix A | R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5 -1 Appendix A | |
Conventional enclosed heating current [Ithe] | 6A | 6A |
Rated insulation voltage [Ui] | 300 V according to UL 508 | 300 V according to UL 508 |
400 V (pollution degree 3) according to EN/IEC 60947-1 | 400 V (pollution degree 3) according to EN/IEC 60947-1 | |
300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
Rated impulse withstand voltage [Uimp] | 4 kV according to EN/IEC 60947-1 | 4 kV according to EN/IEC 60947-1 |
4 kV according to IEC 60664 | 4 kV according to IEC 60664 | |
Maximum resistance across terminals | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
Short circuit protection | 6 A fuse type gG (gl) | 6 A fuse type gG (gl) |
Repeatability | 0.1mm above the trip point, the direct-acting operating head can perform 1 million working cycles | 0.1mm above the trip point, the direct-acting operating head can perform 1 million working cycles |
body material | Zamak | Zamak |
head material | Zamak | Zamak |
Cabinet material | Plastic | Plastic |
depth | 35 mm | 35 mm |
high | 122 mm | 100 mm |
width | 34mm | 34 mm |
product weight | 0.22kg | 0.255 kg |
Environment | ||
Standards compliant | EN/IEC 60947-5-1 | EN 1088/ISO 14119 |
CSA C22.2 No 14 | EN/IEC 60204-1 | |
EN 1088/ISO 14119 | EN/IEC 60947-5-1 | |
UL 508 | UL 508 | |
EN/IEC 60204-1 | CSA C22.2 No 14 | |
certified product | CSA | UL |
UL | CSA | |
Security Level | Category 4 can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 | Category 4 can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 |
PL = e can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 | PL = e can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 | |
SIL 3 can be achieved with appropriate monitoring system and correct wiring according to IEC 61508 | SIL 3 can be achieved with appropriate monitoring system and correct wiring according to IEC 61508 | |
Safe and reliable data | B10d = 50000000 Value determined by 20 years life time, limited by mechanical or contact wear | B10d = 50000000 Value determined by 20 years life time, limited by mechanical or contact wear |
Protective treatment | TC | TC |
operating temperature | -25…70°C | -25…70°C |
storage environment temperature | -40…70°C | -40…70°C |
Anti-vibration | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
impact resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Electric Shock Protection Level | Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 |
Class I conforming to EN/IEC 61140 | Class I conforming to EN/IEC 61140 | |
IP protection class | IP66 conforms to screwed | IP66 conforms to screwed |
IP67 conforms to screwed | IP67 conforms to screwed | |
IK protection class | IK06 conforms to EN 50102 | IK06 conforms to EN 50102 |
Packaging unit | ||
Unit Type of Package 1 | PCE | PCE |
Number of Units in Package 1 | 1 | 1 |
Package 1 Height | 3cm | 3.4cm |
Package 1 Width | 13cm | 5.0cm |
Package 1 Length | 5cm | 13.0cm |
Package 1 Weight | 250g | 208.0g |
Unit Type of Package 2 | S01 | S01 |
Number of Units in Package 2 | Twenty one | Twenty one |
Package 2 Height | 15cm | 15.0cm |
Package 2 Width | 15cm | 15.0cm |
Package 2 Length | 40cm | 40.0cm |
Package 2 Weight | 5.643 kg | 4.616 kg |
Contract warranty | ||
Warranty | 18 months | 18 months |
[/fusion_table]
Weight | N/A |
---|---|
Dimensions | N/A |
Model | XCSD3719P20, XCSD3902P20 |