Specifications
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main Information | |
Part Number | XY2CD111 |
Product Series | Telemecanique Emergency stop rope pull switches XY2C |
product type | Simple Pull Rope Switch |
product short name | XY2CD |
shell color | Orchid |
Type of overvoltage | Class I conforming to EN/IEC 61140 |
Class I conforming to NF C 20-030 | |
Additional information | |
cable length | 6 meters |
body material | Zamak |
head material | Plastic |
Rated supply voltage [Us] | 240V |
contact type | 1 NC + 1 NO |
contact action | Momentary |
Resistance to wrenching | 237 daN operating head |
36 daN operating ring | |
Number of cable entry holes | 3 3 holed entry for Pg 13.5 cable glands for Pg 13.5 |
Mechanical life | 1500000 times |
Rated operating current [Ie] | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A |
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A | |
Conventional enclosed heating current [Ithe] | 10A |
Rated insulation voltage [Ui] | 400 V (pollution degree 3) conforming to EN/IEC 60947-1 |
300 V conforming to UL 508 | |
300 V conforming to CSA C22.2 No 14 | |
model | XY2CD |
environment | |
certified product | CCC |
CE | |
operating temperature | -20…70°C |
IP protection class | IP66 Compliant with screwed |
packaging unit | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 3.200 cm |
Package 1 Width | 6.500 cm |
Package 1 Length | 14.600 cm |
Package 1 Weight | 285.000g |
Unit Type of Package 2 | S01 |
Number of Units in Package 2 | 16 |
Package 2 Height | 15.000 cm |
Package 2 Width | 15.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 4.745 kg |
contract warranty | |
Warranty | 18 months |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
[Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | |
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | |
Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 |
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | |
Signalling type | Steady |
Current consumption | 18 mA |
Service life | 100000 h at rated voltage and 25 °C |
Surge withstand | 1 kV conforming to IEC 61000-4-5 |
Supply voltage limits | 19.2…30 V DC |
21.6…26.4 V AC | |
Device presentation | Complete product |
Environment | |
Protective treatment | TH |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -40…70 °C |
Electrical shock protection class | Class I conforming to IEC 60536 |
IP degree of protection | IP66 conforming to IEC 60529 |
IP67 | |
IP69 | |
IP69K | |
NEMA degree of protection | NEMA 13 |
NEMA 4X | |
IK degree of protection | IK06 conforming to IEC 50102 |
Standards | EN/IEC 60947-5-1 |
JIS C8201-5-1 | |
EN/IEC 60947-5-5 | |
CSA C22.2 No 14 | |
EN/IEC 60947-5-4 | |
EN/IEC 60947-1 | |
UL 508 | |
JIS C8201-1 | |
Product certifications | LROS (Lloyds register of shipping) |
DNV | |
BV | |
GL | |
UL listed | |
CSA | |
Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
Resistance to fast transients | 2 kV conforming to IEC 61000-4-4 |
Resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 |
Resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 |
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
Electromagnetic emission | Class B conforming to IEC 55011 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 3.500 cm |
Package 1 Width | 5.500 cm |
Package 1 Length | 8.500 cm |
[/fusion_table]
Weight | N/A |
---|---|
Dimensions | N/A |
Model | XY2CD111 |