SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6052873
Distance Sensor Model: PRO2-P100B25A1
OEM Spec Ref 

Mechanics/electronics

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Supply voltage Vs DC 12 V (–5 %) … DC 24 V (+10 %) 1)
Power consumption ≤ 180 mA
Warm-up time ≤ 30 min
Housing material Metal (zinc diecast)
Window material Plastic (Polycarbonat (PC))
Connection type Female connector, HRS, 12-pin (I/O, power supply)
Indication 2 LEDs (operational status, Laser on/off)

Dot matrix display

Weight 300 g
Dimensions (W x H x D) 40 mm x 94.5 mm x 60 mm
Enclosure rating IP67
Protection class III

[/fusion_table]

  • 1) When using analog voltage output reduced to 18 V DC (–5%) … 24 V DC (+10%).

Performance

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Measuring range 75 mm … 125 mm
Measuring width (at measuring distance) 17 mm (75 mm)

22 mm (100 mm)

27 mm (125 mm)

Target Natural objects
Repeatability 25 µm, x-direction 1) 2)

2 µm, z-direction

Linearity X-direction ± 170 µm … ± 270 µm 3) 4)

Z-direction ± 50 µm

Response time ≥ 5 ms 5)
Light source Laser, red
visible red light
Laser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 0.3 mm x 32 mm
Additional function Timer (ON-OFF delay, one shot, off), averaging 1 … 1,023, sensitivity (adjustable), Measurement functions (average, peak height, bottom height, width, peak height position, bottom height position, edge position, edge count, tilt, area, length, diameter)

[/fusion_table]

  • 1) Typical value; actual value depends on settings and environmental conditions. For details see field of view.
  • 2) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror; averaging set to: 256; constant ambient conditions.
  • 3) Measurement on 90 % remission (ceramic, white).
  • 4) Constant ambient conditions.
  • 5) Typical value, high-res mode.
  • 6) Wavelength: 655 nm, max. output: 1 mW.

Interfaces

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Serial ✔ , RS-485
Data transmission rate 9.6 kbit/s … 4 Mbit/s, half-duplex
Digital output
Number 3
Type PNP
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Current output
Current 4 mA … 20 mA, ≤ 300 Ω 1)
External input Selectable from bank, trigger, hold, reset, laser off and offset

[/fusion_table]

  • 1) 24 mA for measuring out of range.

Ambient data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ambient temperature, operation –10 °C … +40 °C, Operating temperature at VS = 24 V
Ambient temperature, storage –20 °C … +60 °C
Max. rel. humidity (not condensing) 85 %
Temperature drift ± 0.05 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity Artificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx

Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)