Banner Sensors
Q4X Series: Laser Adjustable Field
Range: 100 mm; Input 12-30 V dc
Output: Analog: 0-10 V
Connection: Euro M12 5-Pin Integral Connector
| Article Number | 94884 | 
| Sensing Beam | Visible Red Laser | 
| Max Measurement Range | <= 100 mm | 
| Power | DC | 
| PC Configurable | No | 
| Sensing Mode (General) | Proximity | 
| Sensing Mode (Detailed) | Background/Foreground Suppression | 
| Housing Style | Rectangular w/M18 Mount | 
| Device Type | Sensor | 
| Primary Housing Material | Stainless Steel | 
| Laser Classification | Class 1 | 
| Input/Output | Analog | 
| Indicator | Display; LED(s) | 
| Connection | Integral QD | 
| Quick Disconnect Type | M12 (Euro) | 
| Analog Resolution/Discrete Repeatability | 0.15 | 
| Max Sensing Distance (mm) | 100 | 
| Minimum Sensing Distance (mm) | 25 | 
| Power Supply | 12-30 V dc | 
| Delay at Power-up (ms) | 750 | 
| Sensing Beam Wavelength (nm) | 655 | 
| Adjustments | Push Button; Remote Teach | 
| Temperature Effect (mm/°C) | +/- 0.05 mm/°C | 
| Number of Pins | 5 | 
| Vibration | MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06″, max acc. 10G). | 
| Mechanical Shock | MIL-STD-202G, Meth. 213B, Cond. I (100G 6x along X, Y & Z axes, 18 total shocks) w/ sensor operating | 
| Analog Current Output Rating | 2.5 kΩ min. load impedance | 
| Output Protection | Protected against continuous overload and short circuit | 
| IP Rating | IP67; IP68; IP69 | 
| Storage Temperature (°C) | -25 to 75 | 
| Max Operating Temperature (°C) | 50 | 
| Min Operating Temperature (°C) | -10 | 
| Max Op. Relative Humidity Non-Condensing (%) | 95 at 55°C | 
| Window Material | Acrylic | 
| Warm-up Time (minutes) | 10 | 
| Minimum Response Time (ms) | 0.5 | 
| Spot Size (@ Reference Distance) | 1.8 mm x 0.7 mm @ 100 mm | 
| Analog Linearity (mm) | +/- 0.25 mm from 25 to 45 mm, 1.0 mm at 100 mm | 
| Minimum Window Size (mm) | 2 | 
| Laser Control | Yes | 
| Alarm Output (mA) | 100 | 
| Max Ambient Light (Lux) | 5000 | 
| Power/Current Consumption (exclusive of load) | < 675 mW | 
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages | 
| Feature: Remote Teach | Yes | 
| Feature: Washdown Rated | Yes | 
| Feature: Timing (Hold/Delay) | No | 
| Feature: Ecolab Certified | Yes | 
| Feature: Chemical Resistant | Yes | 
| Feature: Quick Disconnect | Yes | 
| Common Ethernet Protocol | No | 
| IO Link | No | 
| PROFINET | No | 
| RS-232 | No | 
| RS-422 | No | 
| RS-485 | No | 
| SSI | No | 
| Wireless | No | 
| 1-wire Serial Interface | No | 
| Profibus | No |