Contact Us:
sales@inosaki.com

SENTRON PAC1020 – Siemens Measuring Devices

$ 447.12

SKU 7KM3220-1BA01-1EA0 Category

Features

Model
product brand name SENTRON
product designation Multimeter
design of the product basic
product type designation 7KM PA3220
Measurements
measuring procedure
● for voltage measurement
● for current measurement
TRMS
TRMS
type of measured value detection complete
voltage curve  Sinusoidal or distorted
 measurable line frequency
● initial value 45 Hz
● full-scale value
45 Hz
65 Hz
 operating mode for measured value detection automatic line
frequency detection
Yes
 operating mode for measured value detection
● set at 50 Hz
● set to 60 Hz
No
No
 Supply voltage
design of the power supply  Extra-low voltage power supply unit
 type of voltage of the supply voltage DC
supply voltage at DC 24 … 60 V
Degree of protection protection class
protection class IP on the front  IP65
Suitability
suitability for operation Installation in stationary panels in closed rooms
Product Functions
product function
● voltage measurement
● current measurement
● active power measurement
● reactive power measurement
● frequency measurement
Yes
Yes
Yes
Yes
Yes
Display and operation
design of the display LCD
height of the display 54 mm
width of the display 72 mm
color of the background of the display white
 illuminance of display backlight adjustable No
time-controlled reduction of the illuminance of display backlight
possible
Yes
display contrast adjustable Yes
national language on the display screen is supported de, en, fr, spa, ita, por, tur, chi, pol
number of keys 4
Communication
transfer rate minimum 10 000 kbit/s
transfer rate maximum 101 000 kbit/s
number of interfaces according to Fast Ethernet 2
type of electrical connection of the fast Ethernet interface 2 x RJ45
protocol at the Ethernet interface is supported MODBUS TCP
Fault limits
reference condition for metering accuracy  In accordance with IEC61557-12, IEC62053-22 and IEC62053-23
formula for relative total measurement inaccuracy
● for measured variable voltage
● for measured variable current
● for measured variable active power
● for measured variable reactive power
● for measured variable output factor
● for measured variable active energy
● for measured variable reactive energy
 +/- 0.2 %
+/- 0.2 %
+/- 0.5 %
+/- 1 %
+/- 0,5 %
Cl. 0.5 acc. to… IEC62053-22
Class 2 according to IEC61557-12 and/or IEC62053-23
Inputs Outputs
number of digital inputs 2
type of electrical connection at the digital inputs screw-type terminals
operating conditions for digital inputs external voltage supply Yes
input voltage at digital input at DC maximum 30 V
 input current at digital input
● initial value for signal<1>-recognition
7 mA
number of digital outputs 2
type of switching output bidirectional
digital output version switching or pulse output function
operating voltage as output voltage at DC maximum permissible 30 V
type of electrical connection at the digital outputs screw-type terminals
output current
● at the digital outputs at DC limited to 100 ms maximum
130 mA
internal resistance at the digital outputs 55 Ω
standard for pulse emitter according to IEC62053-31
pulse duration
● initial value
● full-scale value
30 ms
500 ms
adjustable time period minimum 10 ms
switching frequency at digital output maximum 17 Hz
property of the output short-circuit proof Yes
Measuring inputs
measurable supply voltage between (PE)N and L at AC
maximum rated value
400 V
 measurable supply voltage between (PE)N and L at AC
● minimum
● maximum
11.5 V
480 V
measurable supply voltage between the line conductors at AC
maximum rated value
690 V
voltage measuring range extension with external voltage
transformers
yes
line conductors and neutral conductors internal resistance for
voltage measurement
 1.5 MΩ
measuring category for voltage measurement CAT III
measurable current
● 1 at AC rated value
● 2 at AC rated value
1A
5A
relative measurable current at AC
● minimum
● maximum
1%
100%
current measuring range extension with external current
transformers
Yes
zero point suppression for current measurement 0…10%
apparent power consumption for current measurement
● with measuring range 5 A per phase
0.3 VA
measuring category for current measurement  CATIII
Connections
type of electrical connection
● at the measurement inputs for voltage
● at the measurement inputs for current
screw-type terminals
screw-type terminals
Mechanical Design
fastening method DIN-rail mounting No
size of Power Monitoring Device size 96
height 96 mm
width 96 mm
depth 56 mm
installation depth 51 mm
net weight 325 g
mounting position vertical
Environmental conditions
ambient temperature during operation
● minimum
● maximum
-25 °C
55 °C
ambient temperature during storage
● minimum
● maximum
-25 °C
70 °C
relative humidity at 25 °C without condensation during operation
maximum
75%
installation altitude at height above sea level maximum 2 000 m
degree of pollution 2

Additional information

Weight 0.425 kg
Dimensions 9.6 × 5.8 × 9.6 cm

Related Products

SICK_sensor_Inductive proximity sensor_IQG_IQ40-20BPSKK0S
BUM4-40D-W-4M B
Festo_Flow control valves_GRP-160-PK-4_12961
SICK_Compact Photoelectric Sensors-GL10-P4112
IDS_Camera_uEye+_XLS_Board_level_C-Mount_1
IDS_camera_U3-3881SE_1
Select your currency