Manufacturer Part Number: Festo 8035300 #01
Festo Flow Sensors: SFAH-50U-Q6S-PNLK-PNVBA-M8+W5S
OEM Spec Ref
The Festo SFAH-50U-Q6S-PNLK-PNVBA-M8+W5S, MPN 8035300, represents the forefront of flow sensor technology, offering unmatched precision in monitoring and controlling fluid dynamics within a wide range of industrial systems. This state-of-the-art sensor is engineered to deliver high accuracy, reliability, and ease of integration, making it an essential component for optimizing the performance of fluid management systems.
Key Features:
- Superior Accuracy: Ensures precise measurement of flow rates, enabling optimal control and efficiency in processes.
- Durable Construction: Built to withstand the rigors of industrial environments, ensuring long-term reliability and performance.
- Easy Integration: Designed for seamless compatibility with a variety of systems, facilitating quick installation and setup.
- Advanced Diagnostics: Offers detailed monitoring capabilities, aiding in the early detection of potential system inefficiencies or failures.
Benefits:
- Enhanced System Performance: By providing accurate flow measurements, it significantly improves the efficiency and effectiveness of fluid management systems.
- Reduced Operational Costs: The sensor’s durability and precision contribute to lower maintenance expenses and decreased downtime.
- Increased Reliability: High-quality construction and advanced diagnostics ensure consistent operation and extended service life.
- Versatile Application: Suitable for a wide array of industries, including manufacturing, water treatment, and chemical processing.
Applications:
- Process Automation: Vital for regulating fluid flow in automated manufacturing processes, ensuring consistency and quality.
- Water Management: Plays a crucial role in monitoring and controlling water distribution systems for municipal and industrial applications.
- Chemical Processing: Essential for the precise control of chemical flow rates, enhancing safety and product quality.
The Festo SFAH-50U-Q6S-PNLK-PNVBA-M8+W5S flow sensor is a pivotal advancement in fluid management technology. With its exceptional accuracy, robustness, and versatility, it serves as an indispensable asset for a vast range of industrial applications, promising not only to streamline operations but also to significantly reduce costs and improve reliability.
Technical Data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Feature | Specification |
---|---|
Short type code | SFAH |
Certification | RCM Mark UL – Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC Directive As per EU RoHS Directive |
KC marking | KC EMC |
Certificate issuing authority | UL E322346 |
Note on materials | RoHS-compliant |
Measured variable | Mass flow Volumetric flow rate |
Flow direction | Unidirectional |
Measuring principle | Thermal |
Measurement method | Heat transfer |
Start value for flow rate measuring range | 1 l/min |
End value for flow rate measuring range | 50 l/min |
Operating pressure (bar) | -0.900…10,000 bar |
Operating medium | Argon Compressed air as per ISO 8573-1:2010 [6:4:4] Nitrogen |
Temperature of medium | 0…50 °C |
Ambient temperature | 0…50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | +/- (2% o.m.v. + 1% FS) |
Repetition accuracy offset in ± %FS | 0.2 %FS |
Repetition accuracy span in ± %FS | 0.8 %FS |
Temperature coefficient span in ± %FS/K | Typ. 0.15%FS/K |
Pressure influence span in ± %FS/bar | 1 %FS/b. |
Switching output | 2x PNP or 2x NPN switchable |
Switching function | Threshold value comparator Window comparator Auto difference monitoring |
Switching element function | N/C or N/O, switchable |
Max. output current | 100 mA |
Analogue output | 0…10 V 1…5 V 4…20 mA |
Flow characteristic curve start value | 0 l/min |
Max. load resistance current output | 500 Ohm |
Min. load resistance voltage output | 20 kOhm |
Short circuit current rating | Yes |
Overload protection | Available |
Protocol | IO-Link |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBaud) |
IO-Link, SIO-Mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width IN | 3 Byte |
IO-Link®, process data contents IN | 2-bit BDC (flow monitoring) 1 bit BDC (volume monitoring) 14 bit PDV (flow measurement) |
IO-Link, Service data IN | 32 bit volume / mass measured value |
IO-Link®, minimum cycle time | 4 ms |
IO-Link, Data storage required | < 0.500 kB |
Idle current | <= 25,000 mA |
Operating voltage range | DC 22,000…26,000 V |
Reverse polarity protection | For all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connector system | M8x1 A-coded to EN 61076-2-104 |
Electrical connection 1, number of connections/cores | 4 |
Type of mounting | “With accessories” means indirect mounting via an intermediate element. |
Mounting position | Any |
Pneumatic connection | For tubing outside Ų 4 mm |
Pneumatic connection, outlet direction | Straight |
Product weight | 60 g |
Housing material | Reinforced PA |
Material in contact with the medium | NBR PA-reinforced High-alloy stainless steel Wrought aluminium alloy, anodised Silicon Silicon nitride Epoxy |
Display type | Multi-color backlit LCD |
Displayable unit(s) | l/min scft/h g/min L scft G scft/min |
Setting options | IO-Link® Teach-In Via display and keys |
Protection against tampering | IO-Link PIN code |
Degree of protection | IP40 |
Pressure drop | mbar |
Protection class | III |
Corrosion resistance class | moderate corrosion stress – 2 |
[/fusion_table]