The IM 153-1/153-2 interface module serves as the head module (IM; Interface Module) of the ET 200M. Up to 8 or 12 I/O modules from the module product range of the S7-300 automation system can be connected to the interface module.
The interface module and the necessary I/O modules are assembled on a DIN rail for the S7-300. During assembly, the I/O modules are connected to one another using bus connectors and using the IM 153 interface modules.
| Article number | 6ES7153-1AA03-0XB0 | 
| ET200M, Interface Module IM153-1 | |
| General information | |
| Product type designation | IM 153-1 DP ST | 
| Firmware version | |
| Vendor identification (VendorID) | 801Dh | 
| Supply voltage | |
| Rated value (DC) | 24 V | 
| permissible range, lower limit (DC) | 20.4 V | 
| permissible range, upper limit (DC) | 28.8 V | 
| external protection for power supply lines (recommendation) | not necessary | 
| Mains buffering | |
| ● Mains/voltage failure stored energy time | 5 ms | 
| Input current | |
| Current consumption, max. | 350 mA; At 24 V DC | 
| Inrush current, typ. | 2.5 A | 
| I²t | 0.1 A²·s | 
| output voltage / header | |
| Rated value (DC) | 5 V | 
| Output current | |
| for backplane bus (5 V DC), max. | 1 A | 
| Power loss | |
| Power loss, typ. | 3 W | 
| Address area | |
| Addressing volume | |
| ● Inputs | 128 byte | 
| ● Outputs | 128 byte | 
| Hardware configuration | |
| Number of modules per DP slave interface, max. | 8 | 
| Time stamping | |
| Accuracy | |
| Number of message buffers | |
| Messages per message buffer | |
| Number of stampable digital inputs, max. | |
| Time format | |
| Time resolution | |
| Time interval for transmitting the message buffer if a message is present | |
| Time stamp on signal change | |
| Interfaces | |
| Transmission procedure | RS 485 | 
| Transmission rate, max. | 12 Mbit/s | 
| 1. Interface | |
| automatic detection of transmission rate | Yes | 
| Interface types | |
| ● Output current of the interface, max. | 90 mA | 
| ● Design of the connection | 9-pin sub D socket | 
| PROFIBUS DP slave | |
| ● GSD file | (for DPV1) SIEM801D.GSD; SI01801D.GSG | 
| ● automatic baud rate search | Yes | 
| Protocols | |
| Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 | 
| Protocols (Ethernet) | |
| ● TCP/IP | No | 
| PROFIBUS DP | |
| ● Number of node addresses, max. | 1 to 125 permitted | 
| Services | |
| — SYNC capability | Yes | 
| — FREEZE capability | Yes | 
| — Direct data exchange (slave-to-slave communication) | Yes; Sender | 
| Potential separation | |
| Potential separation exists | Yes | 
| Isolation | |
| Isolation tested with | Isolation voltage 500 V | 
| Degree and class of protection | |
| IP degree of protection | IP20 | 
| Ambient conditions | |
| Ambient temperature during operation | |
| ● min. | 0 °C | 
| ● max. | 60 °C | 
| ● horizontal installation, min. | 0 °C | 
| ● horizontal installation, max. | 60 °C | 
| ● vertical installation, min. | 0 °C | 
| ● vertical installation, max. | 40 °C | 
| Altitude during operation relating to sea level | |
| ● Installation altitude above sea level, max. | 3 000 m | 
| configuration / header | |
| Configuration software | |
| ● STEP 7 | STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file | 
| Dimensions | |
| Width | 40 mm | 
| Height | 125 mm | 
| Depth | 117 mm | 
| Weights | |
| Weight, approx. | 360 g | 
| Weight | 0.268 kg | 
|---|---|