The pneumatic interface is designed for an original FESTO valve terminal. ET 200pro can then also be used for applications requiring flexible pneumatics.
A wide variety of valve functions from the standard FESTO spectrum and a choice of flow rates facilitate an extensive range of applications.
CPV 10 or CPV 14 FESTO valve terminals can be used and are available from FESTO.
| Article number | 6ES7148-4EA00-0AA0 | 6ES7148-4EB00-0AA0 | 
| ET200PRO, 16DO,Pneumatic Interface CPV10 | ET200PRO, 16DO,Pneumatic Interface CPV14 | |
| Supply voltage | ||
| Load voltage 2L+ | ||
| ● Rated value (DC) | 24 V | 24 V | 
| ● Short-circuit protection | Yes | Yes | 
| ● Reverse polarity protection | Yes | Yes | 
| Input current | ||
| from load voltage 2L+, max. | 300 mA; Including valves | 370 mA; Including valves | 
| from backplane bus 3.3 V DC, max. | 25 mA | 25 mA | 
| Power loss | ||
| Power loss, typ. | 2.6 W | 3.7 W | 
| Address area | ||
| Address space per module | ||
| ● Address space per module, max. | 2 byte | 2 byte | 
| Digital outputs | ||
| Number of digital outputs | 16 | 16 | 
| Load resistance range | ||
| ● lower limit | 500 Ω | 500 Ω | 
| ● upper limit | 2 500 Ω | 2 500 Ω | 
| Output current | ||
| ● for signal “1” rated value | 12 mA | 16 mA | 
| ● for signal “1” permissible range, min. | 11 mA | 14 mA | 
| ● for signal “1” permissible range, max. | 15 mA | 20 mA | 
| Switching frequency | ||
| ● with inductive load, max. | 25 Hz | 20 Hz | 
| Total current of the outputs (per group) | ||
| all mounting positions | ||
| — up to 55 °C, max. | 250 mA; only up to 50 °C, limited by valves | 330 mA; only up to 50 °C, limited by valves | 
| Interrupts/diagnostics/status information | ||
| Diagnostics function | Yes | Yes | 
| Alarms | ||
| ● Diagnostic alarm | Yes | Yes | 
| Diagnoses | ||
| ● Diagnostic information readable | Yes | Yes | 
| Diagnostics indication LED | ||
| ● Group error SF (red) | Yes | Yes | 
| ● Status indicator digital output (green) | Yes | Yes | 
| Pneumatics | ||
| Number of connectable valves, max. | 16 | 16 | 
| permissible working pressure, min. | 3 bar | 3 bar | 
| permissible working pressure, max. | 8 bar | 8 bar | 
| Rated flow rate | 400 l/min | 800 l/min | 
| Valve switching times from “0” to “1” | 17 ms | 24 ms | 
| Valve switching times from “1” to “0” | 25 ms | 30 ms | 
| Parameter | ||
| Remark | Diagnosis load voltage 2L+ | Diagnosis load voltage 2L+ | 
| Response to CPU/master STOP | No | |
| Potential separation | ||
| between backplane bus and all other circuit components | Yes | Yes | 
| Potential separation digital outputs | ||
| ● between the channels and backplane bus | Yes | Yes | 
| Isolation | ||
| Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 
| Standards, approvals, certificates | ||
| Suitable for safety-related tripping of standard modules | Yes | Yes | 
| Highest safety class achievable for safety-related tripping of standard modules | ||
| ● Performance level according to ISO 13849-1 | PL d | PL d | 
| ● Category according to ISO 13849-1 | Cat. 3 | Cat. 3 | 
| ● SIL acc. to IEC 62061 | SIL 2 | SIL 2 | 
| Dimensions | ||
| Width | 90 mm | 120 mm | 
| Height | 130 mm | 152 mm | 
| Depth | 47 mm | 47 mm | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |