With the BaseUnits (BUs), the ET 200SP offers a rugged and service-friendly design with permanent wiring:
- No tools needed for one-handed wiring using push-in terminals
- Actuation of the spring NC contacts with a standard screwdriver, with a blade width up to 3.5 mm
- Outstanding access due to arrangement of measuring tap, spring NC contacts and cable entry in columns, while at the same time reducing the space required by 64%
- Fault-proof color coding of the spring NC contacts for better orientation in the terminal panel
- Replacement of I/O modules during operation without affecting the wiring
- Operation with module gaps (gaps without I/O module)
- Automatic coding of the I/O modules prevents destruction of the electronics if a module is accidentally inserted in the wrong slot during replacement
- High EMC interference immunity:
- self-assembling shielded backplane bus
- multi-layer conductor plate with shield levels for interference-free signal transmission from the terminal to the I/O module
- system-integrated, space-saving shield connection for quick installation
- Self-assembling potential groups without external wiring or jumpers
- Replaceable terminal box
- Side-by-side latching of the BUs for high mechanical and EMC loads
- Optional module-specific color identification of the terminals according to the color code CC
- Optional equipment marking using slide-in equipment labeling plates
An ET 200SP station can be expanded via one ‘BU-Send’ BaseUnit with a “BA-Send” BusAdapter plugged onto it with up to 16 modules from the ET 200AL series of I/O devices with IP67 protection.
Siemens BaseUnit ET 200SP Product Specifications:
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Article number | 6ES7193-6BP20-0DA0 | 6ES7193-6BP00-0DA0 | 6ES7193-6BP20-0BA0 | 6ES7193-6BP00-0BA0 |
BaseUnit Type A0, BU15-P16+A10+2D | BaseUnit Type A0, BU15-P16+A0+2D | BaseUnit Type A0, BU15-P16+A10+2B | BaseUnit Type A0, BU15-P16+A0+2B | |
General information | ||||
Product type designation | BU type A0 | BU type A0 | BU type A0 | BU type A0 |
HW functional status | From FS07 | From FS06 | From FS06 | From FS06 |
Supply voltage | ||||
Rated value (DC) | 24 V | 24 V | 24 V | 24 V |
external protection for power supply lines | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic |
Mains filter | ||||
● integrated | Yes | No | ||
Current carrying capacity | ||||
For P1 and P2 bus, max. | 10 A | 10 A | 10 A | 10 A |
For AUX bus, max. | 10 A | 10 A | ||
For process terminals, max. | 2 A | 2 A | 2 A | 2 A |
Hardware configuration | ||||
Automatic encoding | Yes | |||
Formation of potential groups | ||||
● New potential group | Yes | Yes | No | No |
● Potential group continued from the left | No | No | Yes | Yes |
Slots | ||||
● Number of slots | 1; Type A0 | 1; Type A0 | 1; Type A0 | 1; Type A0 |
Potential separation | ||||
between the potential groups | Yes | Yes | ||
Isolation | ||||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) |
Ambient conditions | ||||
Ambient temperature during operation | ||||
● horizontal installation, min. | -30 °C | -30 °C | -30 °C | -30 °C |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | 60 °C |
● vertical installation, min. | -30 °C | -30 °C | -30 °C | -30 °C |
● vertical installation, max. | 50 °C | 50 °C | 50 °C | 50 °C |
Altitude during operation relating to sea level | ||||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Accessories | ||||
Color coding labels | ||||
● for process terminals | CC00 to CC09 | CC00 to CC09 | CC00 to CC09 | CC00 to CC09 |
● for AUX terminals | CC71 to CC73 | does not exist | CC71 to CC73 | does not exist |
● for add-on terminals | does not exist | does not exist | does not exist | does not exist |
connection method / header | ||||
Terminals | ||||
● Terminal type | Push-in terminal | Push-in terminal | Push-in terminal | Push-in terminal |
● Conductor cross-section, min. | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 |
● Conductor cross-section, max. | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 |
● Number of process terminals to I/O module | 16 | 16 | 16 | 16; Pro slot |
● Number of terminals to AUX bus | 10 | 0 | 10 | 0 |
● Number of add-on terminals | 0 | 0 | 0 | 0 |
● Number of terminals with connection to P1 and P2 bus | 2 | 2 | 2 | 2; Pro slot |
Dimensions | ||||
Width | 15 mm | 15 mm | 15 mm | 15 mm |
Height | 141 mm | 117 mm | 141 mm | 117 mm |
Depth | 35 mm | 35 mm | 35 mm | 35 mm |
Weights | ||||
Weight, approx. | 50 g | 40 g | 50 g | 40 g |
[/fusion_table]
Weight | N/A |
---|---|
Dimensions | N/A |
Model | BU15-P16+A0+2B, BU15-P16+A0+2D, BU15-P16+A10+2B, BU15-P16+A10+2D |