With the BaseUnits (BUs), the ET 200SP offers a rugged and service-friendly design with permanent wiring:
An ET 200SP station can be expanded via one ‘BU-Send’ BaseUnit with a “BA-Send” BusAdapter plugged onto it with up to 16 modules from the ET 200AL series of I/O devices with IP67 protection.
| Article number | 6ES7193-6BP00-0DU0 | 6ES7193-6B0-0BU0P0 |
| BaseUnit Type U0, BU20-P16+A0+2D, PU 1 | BaseUnit Type U0, BU20-P16+A0+2B, PU 1 | |
| General information | ||
| Product type designation | BU type U0 | BU type U0 |
| HW functional status | FS10 and higher | FS10 and higher |
| Supply voltage | ||
| Rated value (DC) | See manual | See manual |
| ● For P1 and P2 bus | 120 V | 120 V |
| ● For AUX bus | 120 V; Equal potential group to P1/P2 bus or PE | 120 V; Equal potential group to P1/P2 bus or PE |
| ● for process terminals | 120 V | 120 V |
| Rated value (AC) | See manual | See manual |
| ● For P1 and P2 bus | 277 V | 277 V |
| ● For AUX bus | 277 V; Equal potential group to P1/P2 bus or PE | 277 V; Equal potential group to P1/P2 bus or PE |
| ● for process terminals | 277 V | 277 V |
| external protection for power supply lines | Yes | |
| Mains filter | ||
| ● integrated | No | No |
| Current carrying capacity | ||
| up to 60 °C, max. | 10 A | 10 A |
| For P1 and P2 bus, max. | 10 A | 10 A |
| For AUX bus, max. | 10 A | 10 A |
| For process terminals, max. | 10 A; Point of contact, derating depends on the module | 10 A; Point of contact, derating depends on the module |
| Hardware configuration | ||
| Automatic encoding | Yes | Yes |
| Formation of potential groups | ||
| ● New potential group | Yes | No |
| ● Potential group continued from the left | No | Yes |
| Slots | ||
| ● Number of slots | 1 | 1 |
| Potential separation | ||
| between backplane bus and supply voltage | Yes | Yes |
| between process terminals and supply voltage | Yes; Not applicable for process terminals 15 and 16 | Yes; Not applicable for process terminals 15 and 16 |
| between power bus and supply voltage | No | No |
| Isolation | ||
| Isolation tested with | 3 100 V DC | 3 100 V DC |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● horizontal installation, min. | -30 °C | -30 °C |
| ● horizontal installation, max. | 60 °C | 60 °C |
| ● vertical installation, min. | -30 °C | -30 °C |
| ● vertical installation, max. | 50 °C | 50 °C |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 3 000 m | 3 000 m |
| connection method / header | ||
| Terminals | ||
| ● Terminal type | Push-in terminal | Push-in terminal |
| ● Conductor cross-section, min. | 0.14 mm²; 0.2 mm² without wire end ferrule | 0.14 mm²; 0.2 mm² without wire end ferrule |
| ● Conductor cross-section, max. | 2.5 mm²; 1.5 mm² with wire end ferrule | 2.5 mm²; 1.5 mm² with wire end ferrule |
| ● Number of process terminals to I/O module | 16 | 16 |
| ● Number of terminals to AUX bus | 0 | 0 |
| ● Number of add-on terminals | 0 | 0 |
| ● Number of terminals with connection to P1 and P2 bus | 2 | 2 |
| Dimensions | ||
| Width | 20 mm | 20 mm |
| Height | 117 mm | 117 mm |
| Depth | 35 mm | 35 mm |
| Weights | ||
| Weight, approx. | 50 g | 50 g |
| Weight | N/A |
|---|---|