| Article number |
6ES7137-6AA01-0BA0 |
|
ET 200SP, CM PTP, PU 1 |
| General information |
|
| Product type designation |
CM PtP |
| Firmware version |
|
| ● FW update possible |
Yes |
| usable BaseUnits |
BU type A0 |
| Product function |
|
| ● I&M data |
Yes; I&M0 to I&M3 |
| Engineering with |
|
| ● STEP 7 TIA Portal configurable/integrated from version |
STEP 7 V17 or higher |
| ● STEP 7 configurable/integrated from version |
via GSD as of V5.6 HF4 |
| ● PROFIBUS from GSD version/GSD revision |
GSD as of Revision 5 |
| ● PROFINET from GSD version/GSD revision |
GSDML V2.34 |
| Supply voltage |
|
| Rated value (DC) |
24 V |
| permissible range, lower limit (DC) |
19.2 V |
| permissible range, upper limit (DC) |
28.8 V |
| Reverse polarity protection |
Yes |
| Input current |
|
| Current consumption (rated value) |
31 mA |
| Current consumption, max. |
35 mA |
| Power loss |
|
| Power loss, typ. |
0.7 W |
| Address area |
|
| Address space per module |
|
| ● Inputs |
8 byte; performance mode: 32 byte |
| ● Outputs |
0 byte; performance mode: 32 byte |
| 1. Interface |
|
| Interface types |
|
| ● RS 485 |
Yes |
| ● RS 422 |
Yes |
| ● RS 232 |
Yes |
| ● Design of the connection |
Push-in terminal |
| Interface types |
|
| RS 232 |
|
| ● Transmission rate, max. |
115.2 kbit/s |
| ● Cable length, max. |
15 m |
| ● RS 232 auxiliary signals |
RTS, CTS, DTR, DSR, RI, DCD |
| RS 485 |
|
| ● Transmission rate, max. |
250 kbit/s |
| ● Cable length, max. |
1 200 m; 100 to 1200 m, depending on transmission speed |
| RS 422 |
|
| ● Transmission rate, max. |
115.2 kbit/s |
| ● Cable length, max. |
1 200 m |
| ● 4-wire full duplex connection |
Yes |
| ● 4-wire multipoint connection |
Yes |
| Protocols |
|
| Integrated protocols |
|
| Freeport |
|
| — Telegram length, max. |
2 kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte |
| — Bits per character |
7 or 8 |
| — Number of stop bits |
1 or 2 bit |
| — Parity |
None, even, odd, always 1, always 0, any |
| 3964 (R) |
|
| — Telegram length, max. |
2 kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte |
| — Bits per character |
7 or 8 |
| — Number of stop bits |
1 or 2 bit |
| — Parity |
None, even, odd, always 1, always 0, any |
| Modbus RTU master |
|
| — Address area |
1 to 247, extended 1 to 65535 |
| — Number of slaves, max. |
32 |
| MODBUS RTU slave |
|
| — Address area |
1 to 247, extended 1 to 65535 |
| Telegram buffer |
|
| ● Buffer memory for telegrams |
4 kbyte |
| ● Number of telegrams which can be buffered |
255 |
| Interrupts/diagnostics/status information |
|
| Diagnostics function |
Yes |
| Alarms |
|
| ● Diagnostic alarm |
Yes |
| ● Hardware interrupt |
No |
| Diagnoses |
|
| ● Wire-break |
Yes |
| Diagnostics indication LED |
|
| ● Monitoring of the supply voltage (PWR-LED) |
Yes; green PWR LED |
| ● for module diagnostics |
Yes; green/red DIAG LED |
| ● Receive RxD |
Yes; green LED |
| ● Transmit TxD |
Yes; green LED |
| Potential separation |
|
| between backplane bus and interface |
Yes |
| Isolation |
|
| Isolation tested with |
707 V DC (type test) |
| Ambient conditions |
|
| Ambient temperature during operation |
|
| ● horizontal installation, min. |
-30 °C |
| ● horizontal installation, max. |
60 °C |
| ● vertical installation, min. |
-30 °C |
| ● vertical installation, max. |
50 °C |
| Altitude during operation relating to sea level |
|
| ● Installation altitude above sea level, max. |
5 000 m |
| Decentralized operation |
|
| to SIMATIC S7-300 |
Yes |
| to SIMATIC S7-400 |
Yes |
| to SIMATIC S7-1200 |
Yes |
| to SIMATIC S7-1500 |
Yes |
| to standard PROFINET controller |
Yes |
| Dimensions |
|
| Width |
15 mm |
| Height |
73 mm |
| Depth |
58 mm |
| Weights |
|
| Weight, approx. |
30 g |