| Article number |
6ES7136-6RA00-0BF0 |
|
ET 200SP, F-RQ 1x24VDC/24..230VAC/5A ST |
| General information |
|
| Product type designation |
F-RQ 24 … 48VDC/24 … 230VAC/5A ST |
| usable BaseUnits |
BU type F0 |
| Color code for module-specific color identification plate |
CC42 |
| Product function |
|
| ● I&M data |
Yes; I&M0 to I&M3 |
| Engineering with |
|
| ● STEP 7 TIA Portal configurable/integrated from version |
V13 |
| ● STEP 7 configurable/integrated from version |
V5.5 SP4 and higher |
| ● PROFINET from GSD version/GSD revision |
V2.31 |
| Supply voltage |
|
| Rated value (DC) |
24 V; Coil voltage |
| permissible range, lower limit (DC) |
20.4 V |
| permissible range, upper limit (DC) |
28.8 V |
| power supply according to NEC Class 2 required |
No |
| Power |
|
| Power available from the backplane bus |
100 mW |
| Power loss |
|
| Power loss, typ. |
1 W |
| Address area |
|
| Address space per module |
|
| ● Inputs |
1 byte |
| Hardware configuration |
|
| Automatic encoding |
Yes |
| ● Mechanical coding element |
Yes |
| ● Type of mechanical coding element |
type C |
| Digital outputs |
|
| Type of digital output |
Relays |
| Number of digital outputs |
1 |
| Limitation of inductive shutdown voltage to |
No |
| Controlling a digital input |
Yes |
| Switching capacity of the outputs |
|
| ● with resistive load, max. |
5 A |
| ● on lamp load, max. |
25 W |
| Switching frequency |
|
| ● with resistive load, max. |
2 Hz |
| ● with inductive load, max. |
0.1 Hz; See data in manual |
| ● with inductive load (acc. to IEC 60947-5-1, DC13), max. |
0.1 Hz |
| ● with inductive load (acc. to IEC 60947-5-1, AC15), max. |
2 Hz |
| Total current of the outputs (per module) |
|
| horizontal installation |
|
| — up to 40 °C, max. |
5 A; note derating data in the manual |
| — up to 50 °C, max. |
4 A; note derating data in the manual |
| — up to 60 °C, max. |
3 A; note derating data in the manual |
| vertical installation |
|
| — up to 50 °C, max. |
3 A; note derating data in the manual |
| Relay outputs |
|
| ● Number of relay outputs |
1; 2 NO contacts |
| ● Rated supply voltage of relay coil L+ (DC) |
24 V |
| ● Current consumption of relays (coil current of all relays), max. |
70 mA |
| ● external protection for relay outputs |
yes; 6 A, see data in manual |
| ● Relay approved acc. to UL 508 |
Yes; Pilot Duty B300, R300 |
| Switching capacity of contacts |
|
| — with inductive load, max. |
see additional description in the manual |
| — with resistive load, max. |
see additional description in the manual |
| — Thermal continuous current, max. |
5 A |
| — Switching current, min. |
1 mA |
| — Switching current after exceeding 300 mA, min. |
10 mA |
| — Switching current after exceeding 300 mA, max. |
5 A |
| — Rated switching voltage (DC) |
24 V |
| — Rated switching voltage (AC) |
230 V |
| Cable length |
|
| ● shielded, max. |
500 m; for load contacts |
| ● unshielded, max. |
300 m; for load contacts |
| ● Control cable (input), max. |
10 m |
| Interrupts/diagnostics/status information |
|
| Diagnostics function |
Yes |
| Diagnostics indication LED |
|
| ● RUN LED |
Yes; green/red DIAG LED |
| ● Channel status display |
Yes; green LED |
| Potential separation |
|
| Potential separation channels |
|
| ● between the channels |
Yes; for SELV / PELV only |
| ● between the channels and backplane bus |
Yes |
| ● between the channels and the power supply of the electronics |
Yes |
| Permissible potential difference |
|
| between channels and backplane bus/supply voltage |
250 V AC (reinforced insulation) |
| Isolation |
|
| Isolation tested with |
2 545 V DC/2 s (routine test) |
| Overvoltage category |
III |
| tested with |
|
| ● between channels and backplane bus/supply voltage |
DC 2 545 V 2 s (routine test), impulse voltage test DC 7 200 V / 5 positive and 5 negative pulses (type test) |
| ● between backplane bus and supply voltage |
707 V DC (type test) |
| Standards, approvals, certificates |
|
| Suitable for safety functions |
Yes |
| Highest safety class achievable in safety mode |
|
| ● Performance level according to ISO 13849-1 |
PLe |
| ● Category according to ISO 13849-1 |
4 |
| ● SIL acc. to IEC 61508 |
SIL 3 |
| Probability of failure (for service life of 20 years and repair time of 100 hours) |
|
| — Low demand mode: PFDavg in accordance with SIL2 |
< 1.00E-04, function test 1x per year |
| — Low demand mode: PFDavg in accordance with SIL3 |
< 1.00E-05, function test 1x per month |
| — High demand/continuous mode: PFH in accordance with SIL2 |
< 1.00E-08 1/h, function test 1x per year |
| — High demand/continuous mode: PFH in accordance with SIL3 |
< 6.00E-09 1/h, function test 1x per month |
| Ambient conditions |
|
| Ambient temperature during operation |
|
| ● horizontal installation, min. |
0 °C |
| ● horizontal installation, max. |
60 °C |
| ● vertical installation, min. |
0 °C |
| ● vertical installation, max. |
50 °C |
| Dimensions |
|
| Width |
20 mm |
| Height |
73 mm |
| Depth |
58 mm |
| Weights |
|
| Weight, approx. |
56 g |