| Article number |
6ES7131-6BF00-0CA0 |
6ES7131-6BF00-0DA0 |
6ES7131-6TF00-0CA0 |
6ES7131-6FD01-0BB1 |
6ES7131-6CF00-0AU0 |
|
ET 200SP, DI 8x24VDC HF, PU 1 |
ET 200SP, DI 8x24VDC High Speed |
ET 200SP, DI 8xNAMUR HF |
ET 200SP, DI 4x 120..230VvAC ST |
ET 200SP, DI 8x 24VAC..48VUC BA, PU 1 |
| General information |
|
|
|
|
|
| Product type designation |
DI 8×24 V DC HF |
DI 8×24 V DC HS |
DI 8xNAMUR HF |
DI 4×120 … 230 V AC ST |
DI 8x24VAC/48VUC BA |
| HW functional status |
From FS07 |
from FS04 |
from FS04 |
From FS02 |
From FS02 |
| Firmware version |
|
V1.0.2 |
|
V0.0 |
V0.0 |
| ● FW update possible |
Yes |
Yes |
Yes |
No |
No |
| usable BaseUnits |
BU type A0 |
BU type A0 |
BU type A0 |
BU type B1 |
BU type U0 |
| Color code for module-specific color identification plate |
CC01 |
CC01 |
CC01 |
CC41 |
|
| Product function |
|
|
|
|
|
| ● I&M data |
Yes; I&M0 to I&M3 |
Yes; I&M0 to I&M3 |
Yes; I&M0 to I&M3 |
Yes; I&M0 to I&M3 |
|
| ● Isochronous mode |
Yes |
Yes |
No |
No |
No |
| Engineering with |
|
|
|
|
|
| ● STEP 7 TIA Portal configurable/integrated from version |
V13 SP1 / – |
V13 SP1 |
V13 / V13 |
V14 |
V15 |
| ● STEP 7 configurable/integrated from version |
V5.5 / – |
V5.5 SP3 / – |
V5.5 SP3 / – |
V5.5 SP3 |
V5.6 |
| ● PCS 7 configurable/integrated from version |
V8.1 SP1 |
|
|
|
|
| ● PROFIBUS from GSD version/GSD revision |
One GSD file each, Revision 3 and 5 and higher |
One GSD file each, Revision 3 and 5 and higher |
GSD Revision 5 |
One GSD file each, Revision 3 and 5 and higher |
One GSD file each, Revision 3 and 5 and higher |
| ● PROFINET from GSD version/GSD revision |
GSDML V2.3 |
GSDML V2.3 |
GSDML V2.3 |
GSDML V2.3 |
GSDML V2.3 |
| Operating mode |
|
|
|
|
|
| ● DI |
Yes |
Yes |
Yes |
Yes |
Yes |
| ● Counter |
No |
Yes |
No |
No |
No |
| ● Oversampling |
No |
Yes |
No |
No |
No |
| ● MSI |
Yes |
No |
No |
No |
No |
| Supply voltage |
|
|
|
|
|
| Rated value (DC) |
24 V |
24 V |
24 V |
|
48 V |
| permissible range, lower limit (DC) |
19.2 V |
19.2 V |
19.2 V |
|
40.8 V |
| permissible range, upper limit (DC) |
28.8 V |
28.8 V |
28.8 V |
|
57.6 V |
| Rated value (AC) |
|
|
|
230 V |
48 V; 24 V/48 V; 50 Hz/60 Hz |
| permissible range, lower limit (AC) |
|
|
|
187 V |
40.8 V |
| permissible range, upper limit (AC) |
|
|
|
264 V |
52.8 V |
| Reverse polarity protection |
Yes |
Yes |
Yes |
No |
Yes |
| Input current |
|
|
|
|
|
| Current consumption (rated value) |
|
|
|
10 mA |
|
| Current consumption, max. |
|
70 mA; without sensor supply |
|
|
70 mA; without sensor supply |
| Encoder supply |
|
|
|
|
|
| Number of outputs |
8 |
|
8 |
4 |
8 |
| Output voltage, min. |
19.2 V |
|
|
|
|
| Short-circuit protection |
Yes |
|
Yes |
No; when using BU type B1, a fuse with 10 A tripping current must be provided |
Yes; Per module, 5x 20 mm fuse, 2 A/250 V, quick-response, replaceable |
| Output current |
|
|
|
|
|
| ● up to 60 °C, max. |
|
|
|
10 A |
1 A |
| 24 V encoder supply |
|
|
|
|
|
| ● 24 V |
Yes |
Yes |
No |
|
No |
| ● Short-circuit protection |
Yes; per channel, electronic |
Yes; per module, electronic |
No |
|
|
| ● Output current, max. |
|
700 mA |
|
|
|
| ● Output current per channel, max. |
700 mA |
|
|
|
|
| ● Output current per module, max. |
700 mA |
|
|
|
|
| Power loss |
|
|
|
|
|
| Power loss, typ. |
1.5 W; 24 V, 8 inputs supplied via encoder supply |
1.5 W |
1.5 W |
1 W; Active power, load voltage 230 V, all inputs connected with 230 V, 50 Hz |
1.5 W |
| Address area |
|
|
|
|
|
| Address space per module |
|
|
|
|
|
| ● Address space per module, max. |
|
45 byte |
1 byte; + 1 byte for QI information |
|
1 byte |
| ● Inputs |
1 byte; + 1 byte for QI information |
32 byte; 1 byte + 1 byte for QI information in DI mode; 32 bytes in Oversampling mode; 25 bytes in Counter mode |
|
1 byte; + 1 byte for QI information |
|
| ● Outputs |
|
20 byte; In count mode |
|
|
|
| Hardware configuration |
|
|
|
|
|
| Automatic encoding |
Yes |
Yes |
|
Yes |
|
| ● Mechanical coding element |
Yes |
Yes |
|
Yes |
Yes |
| ● Type of mechanical coding element |
Type A |
Type A |
Type A |
type C |
type C |
| Submodules |
|
|
|
|
|
| ● Number of configurable submodules, max. |
4 |
|
|
|
|
| Selection of BaseUnit for connection variants |
|
|
|
|
|
| ● 1-wire connection |
BU type A0 |
BU type A0 |
BU type A0 |
BU type B1 |
BU type U0 |
| ● 2-wire connection |
BU type A0 |
BU type A0 |
BU type A0 |
BU type B1 |
BU type U0 |
| ● 3-wire connection |
BU type A0 with AUX terminals or potential distributor module |
BU type A0 with AUX terminals |
BU type A0 + external terminals |
BU type B1 |
BU type U0 + Potential distributor module |
| ● 4-wire connection |
BU type A0 + Potential distributor module |
BU type A0 + external terminals |
BU type A0 + external terminals |
BU type B1 + potential distributor module |
BU type U0 + Potential distributor module |
| Digital inputs |
|
|
|
|
|
| Number of digital inputs |
8 |
8 |
8; NAMUR |
4 |
8 |
| Digital inputs, parameterizable |
Yes |
|
Yes |
|
|
| Source/sink input |
P-reading |
P-reading |
|
|
P-reading |
| Input characteristic curve in accordance with IEC 61131, type 1 |
|
|
|
|
Yes |
| Input characteristic curve in accordance with IEC 61131, type 2 |
|
|
|
|
No |
| Input characteristic curve in accordance with IEC 61131, type 3 |
Yes |
|
|
Yes |
No |
| Pulse extension |
Yes; Pulse duration from 4 µs |
Yes |
Yes; 0.5 s, 1 s, 2 s |
|
No |
| ● Length |
2 s; 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s |
2 s; 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s |
|
|
|
| Edge evaluation |
Yes; rising edge, falling edge, edge change |
|
Yes; rising edge, falling edge, edge change |
|
|
| Signal change flutter |
|
|
Yes; 2 to 32 signal changes |
|
|
| Flutter observation window |
|
|
Yes; 0.5 s, 1 s to 100 s in 1-s steps |
|
|
| Digital input functions, parameterizable |
|
|
|
|
|
| ● Gate start/stop |
|
Yes |
|
|
|
| ● Freely usable digital input |
|
Yes |
|
|
|
| ● Counter |
|
Yes |
|
|
|
| — Number, max. |
|
4 |
|
|
|
| — Counting frequency, max. |
|
10 kHz |
|
|
|
| — Counting width |
|
32 bit |
|
|
|
| — Counting direction up/down |
|
Yes |
|
|
|
| ● Digital input with oversampling |
|
Yes |
|
|
|
| — Number, max. |
|
8 |
|
|
|
| — Values per cycle, max. |
|
32 |
|
|
|
| — Resolution, min. |
|
7.8125 µs |
|
|
|
| Input voltage |
|
|
|
|
|
| ● Rated value (DC) |
24 V |
24 V |
8.2 V |
|
|
| ● Rated value (AC) |
|
|
|
230 V |
|
| ● for signal “0” |
-30 to +5 V |
-30 to +5 V |
|
0V AC to 40V AC |
AC/DC < 10 V |
| ● for signal “1” |
+11 to +30V |
+11 to +30V |
|
74 V AC to 264 V AC |
AC > 14 V, DC > 34 V |
| Input current |
|
|
|
|
|
| ● for signal “1”, typ. |
2.5 mA |
6 mA |
|
10.8 mA |
3.5 mA |
| for 10 k switched contact |
|
|
|
|
|
| — for signal “0” |
|
|
0.35 to 1.2 mA |
|
|
| — for signal “1” |
|
|
2.1 to 7 mA |
|
|
| for unswitched contact |
|
|
|
|
|
| — for signal “0”, max. (permissible quiescent current) |
|
|
0.5 mA |
|
|
| — for signal “1” |
|
|
typ. 8 mA |
|
|
| for NAMUR encoders |
|
|
|
|
|
| — for signal “0”, min. |
|
|
0.35 mA |
|
|
| — for signal “0”, max. |
|
|
1.2 mA |
|
|
| — for signal “1”, min. |
|
|
2.1 mA |
|
|
| — for signal “1”, max. |
|
|
7 mA |
|
|
| Input delay (for rated value of input voltage) |
|
|
|
|
|
| ● tolerated changeover time for changeover contacts |
|
|
300 ms |
|
|
| for standard inputs |
|
|
|
|
|
| — parameterizable |
Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length) |
Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms |
No |
No |
No |
| — at “0” to “1”, min. |
0.05 ms |
|
|
1.5 ms |
|
| — at “0” to “1”, max. |
20 ms |
|
|
4 ms |
15 ms |
| — at “1” to “0”, min. |
0.05 ms |
|
|
10 ms |
|
| — at “1” to “0”, max. |
20 ms |
|
|
10 ms |
20 ms |
| for interrupt inputs |
|
|
|
|
|
| — parameterizable |
|
Yes |
|
|
|
| for technological functions |
|
|
|
|
|
| — parameterizable |
|
Yes |
|
|
|
| for NAMUR inputs |
|
|
|
|
|
| — at “0” to “1”, max. |
|
|
12 ms |
|
|
| — at “1” to “0”, max. |
|
|
12 ms |
|
|
| Cable length |
|
|
|
|
|
| ● shielded, max. |
1 000 m |
50 m |
200 m |
1 000 m |
1 000 m |
| ● unshielded, max. |
600 m |
50 m |
|
600 m |
600 m |
| Encoder |
|
|
|
|
|
| Connectable encoders |
|
|
|
|
|
| ● NAMUR encoder/changeover contact according to EN 60947 |
|
|
Yes |
|
|
| ● Single contact / changeover contact unconnected |
|
|
Yes |
|
|
| ● Single contact / changeover contact connected with 10 kΩ |
|
|
Yes |
|
|
| ● 2-wire sensor |
Yes |
Yes |
|
Yes |
Yes |
| — permissible quiescent current (2-wire sensor), max. |
1.5 mA |
1.5 mA |
|
|
|
| Isochronous mode |
|
|
|
|
|
| Filtering and processing time (TCI), min. |
420 µs |
|
|
|
|
| Bus cycle time (TDP), min. |
500 µs |
125 µs |
|
|
|
| Jitter, max. |
8 µs |
5 µs |
|
|
|
| Interrupts/diagnostics/status information |
|
|
|
|
|
| Diagnostics function |
Yes |
Yes |
Yes |
|
Yes |
| Alarms |
|
|
|
|
|
| ● Diagnostic alarm |
Yes; channel by channel |
Yes |
Yes; channel by channel |
No |
Yes |
| ● Hardware interrupt |
Yes; Parameterizable, channels 0 to 7 |
Yes |
Yes; Parameterizable, channels 0 to 7 |
No |
|
| Diagnoses |
|
|
|
|
|
| ● Diagnostic information readable |
Yes |
Yes |
Yes |
|
Yes |
| ● Monitoring the supply voltage |
Yes |
Yes |
Yes |
No |
Yes |
| — parameterizable |
Yes |
Yes |
Yes |
|
|
| ● Monitoring of encoder power supply |
Yes; channel by channel |
Yes; Module-wise |
No |
|
Yes |
| ● Wire-break |
Yes; Channel by channel, optional protective circuit for preventing wire-break diagnostics in the case of simple encoder contacts: 25 kOhm to 45 kOhm |
No |
Yes; channel by channel |
No |
|
| ● Short-circuit |
Yes; channel by channel |
Yes; Module-wise |
Yes; channel by channel |
No |
|
| ● Group error |
|
|
|
|
Yes |
| Diagnostics indication LED |
|
|
|
|
|
| ● Monitoring of the supply voltage (PWR-LED) |
Yes; green PWR LED |
Yes; green PWR LED |
Yes; green PWR LED |
Yes; green PWR LED |
Yes; green PWR LED |
| ● Channel status display |
Yes; green LED |
Yes; green LED |
Yes; green LED |
Yes; green LED |
Yes; green LED |
| ● for channel diagnostics |
Yes; red LED |
No |
Yes; red LED |
No |
No |
| ● for module diagnostics |
Yes; green/red DIAG LED |
Yes; green/red DIAG LED |
Yes; green/red DIAG LED |
Yes; green/red DIAG LED |
Yes; green/red DIAG LED |
| Potential separation |
|
|
|
|
|
| Potential separation channels |
|
|
|
|
|
| ● between the channels |
No |
No |
No |
No |
No |
| ● between the channels and backplane bus |
Yes |
Yes |
Yes |
Yes |
Yes |
| ● between the channels and the power supply of the electronics |
No |
No |
Yes |
No |
No |
| Isolation |
|
|
|
|
|
| Isolation tested with |
707 V DC (type test) |
707 V DC (type test) |
707 V DC (type test) |
2 545 V DC/2 s (routine test) |
1 200 V DC between supply voltage and backplane bus |
| Standards, approvals, certificates |
|
|
|
|
|
| Suitable for safety functions |
No |
No |
No |
No |
No |
| Ambient conditions |
|
|
|
|
|
| Ambient temperature during operation |
|
|
|
|
|
| ● horizontal installation, min. |
-30 °C; < 0 °C as of FS07 |
-30 °C; < 0 °C as of FS04 |
-30 °C |
-30 °C |
-30 °C |
| ● horizontal installation, max. |
60 °C |
60 °C |
60 °C |
60 °C |
60 °C |
| ● vertical installation, min. |
-30 °C; < 0 °C as of FS07 |
-30 °C; < 0 °C as of FS04 |
-30 °C |
-30 °C |
-30 °C |
| ● vertical installation, max. |
50 °C |
50 °C |
50 °C |
50 °C |
50 °C |
| Altitude during operation relating to sea level |
|
|
|
|
|
| ● Installation altitude above sea level, max. |
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
2 000 m; On request: Installation altitudes greater than 2 000 m |
2 000 m; On request: Installation altitudes greater than 2 000 m |
| Dimensions |
|
|
|
|
|
| Width |
15 mm |
15 mm |
15 mm |
20 mm |
20 mm |
| Height |
73 mm |
73 mm |
73 mm |
73 mm |
73 mm |
| Depth |
58 mm |
58 mm |
58 mm |
58 mm |
58 mm |
| Weights |
|
|
|
|
|
| Weight, approx. |
28 g |
28 g |
32 g |
36 g |
40 g |