SIMATIC IM155-6MF High Feature, MultiFieldbus IM with two slots for SIMATIC BusAdapters
Differences compared to the 2-port IM155-6PN/2 High Feature:
| Article number | 6ES7155-6MU00-0CN0 | 
| ET 200SP, IM155-6MF HF | |
| General information | |
| Product type designation | IM 155-6 MF HF | 
| Firmware version | V5.1.1 | 
| ● FW update possible | Yes | 
| Vendor identification (VendorID) | 002AH | 
| Device identifier (DeviceID) | 0313H | 
| Manufacturer ID according to ODVA (VendorID) | 04E3H | 
| Device ID according to ODVA (Product code) | 0FA2H | 
| Product function | |
| ● I&M data | Yes; I&M0 to I&M3 | 
| ● Module swapping during operation (hot swapping) | Yes; Multi-hot swapping | 
| ● Isochronous mode | No | 
| ● Tool changer | Yes; Docking station and docking unit | 
| ● Local coupling, IO data | No | 
| ● Local coupling, data records | No | 
| Engineering with | |
| ● STEP 7 TIA Portal configurable/integrated from version | via IM155-6PN/2 HF in compatibility mode | 
| ● STEP 7 configurable/integrated from version | via IM155-6PN/2 HF in compatibility mode | 
| ● PROFINET from GSD version/GSD revision | GSDML V2.3 | 
| ● Multi Fieldbus Configuration Tool (MFCT) | V1.0 Update 2 | 
| Configuration control | |
| via dataset | Yes | 
| Supply voltage | |
| Rated value (DC) | 24 V | 
| permissible range, lower limit (DC) | 19.2 V | 
| permissible range, upper limit (DC) | 28.8 V | 
| Reverse polarity protection | Yes | 
| Mains buffering | |
| ● Mains/voltage failure stored energy time | 10 ms; according to IEC 61131-2 (6.2.1.3) severity degree PS2 | 
| Input current | |
| Current consumption, max. | 700 mA | 
| Inrush current, max. | 4.5 A | 
| I²t | 0.25 A²·s | 
| Power loss | |
| Power loss, typ. | 2.4 W | 
| Address area | |
| Address space per module | |
| ● Address space per module, max. | 288 byte; For input and output data respectively | 
| Address space per station | |
| ● Address space per station, max. | 1 440 byte; Dependent on configuration | 
| Hardware configuration | |
| Rack | |
| ● Quantity of operable ET 200SP modules, max. | 64 | 
| ● Quantity of operable ET 200AL modules, max. | 16 | 
| Submodules | |
| ● Number of submodules per station, max. | 256 | 
| Time stamping | |
| Accuracy | 10 ms | 
| Interfaces | |
| Number of PROFINET interfaces | 1; 2 ports (switch) | 
| 1. Interface | |
| Interface types | |
| ● Number of ports | 2; via BusAdapter | 
| ● integrated switch | Yes | 
| ● BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC, | 
| Protocols | |
| ● PROFINET IO Device | Yes | 
| ● Open IE communication | Yes | 
| ● Media redundancy | Yes; PROFINET MRP | 
| Interface types | |
| RJ 45 (Ethernet) | |
| ● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | 
| ● 10 Mbps | No | 
| ● 100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | 
| ● Autonegotiation | Yes | 
| ● Autocrossing | Yes | 
| Protocols | |
| Modbus TCP | Yes | 
| Number of connections | |
| ● Number of MtM communication relationships/connections, max. | 16 | 
| PROFINET IO Device | |
| Services | |
| — IRT | No | 
| — PROFIenergy | Yes | 
| — Prioritized startup | No | 
| — Shared device | No | 
| Redundancy mode | |
| ● PROFINET system redundancy (S2) | Yes; NAP S2 | 
| ● H-Sync forwarding | Yes | 
| Media redundancy | |
| — MRP | Yes | 
| — MRPD | No | 
| EtherNet/IP | |
| Services | |
| — CIP Implicit Messaging | Yes | 
| — CIP Explicit Messaging | Yes | 
| — CIP Safety | No | 
| — Configuration control via Explicit Messaging | No | 
| — Shared device | No | 
| Updating times | |
| — Requested Packet Interval (RPI) | 2 ms | 
| Address area | |
| — Address space per module, max. | 288 byte; (246 byte outputs / 288 byte inputs) | 
| — ForwardOpen (Class1 & 32 bit Header) | 500 byte; (246 byte outputs / 500 byte inputs) | 
| — LargeForwardOpen (Class3) | 4 002 byte | 
| Connections | |
| — Number of rack connections | 1 | 
| Modbus TCP | |
| Services | |
| — Read Holding Registers (Code=3) | Yes | 
| — Write Multiple Registers (Code=16) | Yes | 
| — Parameter change by master | Yes | 
| — Modbus TCP Security Protocol | No | 
| Address space per station | |
| — Address space per station, max. | 500 byte; (246 byte outputs / 500 byte inputs) | 
| — Access-consistent address space | 250 byte; (246 byte outputs / 250 byte inputs) | 
| Updating time | |
| — I/O request interval | 2 ms | 
| Connections | |
| — Number of connections per slave | 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info) | 
| Open IE communication | |
| ● TCP/IP | Yes | 
| ● UDP | Yes | 
| ● SNMP | Yes | 
| ● LLDP | Yes | 
| ● ARP | Yes | 
| ● IGMP | Yes | 
| ● Multicast | Yes | 
| ● Broadcast | Yes | 
| ● IPv4 | Yes | 
| Interrupts/diagnostics/status information | |
| Status indicator | Yes | 
| Alarms | Yes | 
| Diagnostics function | Yes | 
| Diagnostics indication LED | |
| ● RUN LED | Yes; green LED | 
| ● ERROR LED | Yes; red LED | 
| ● MAINT LED | Yes; Yellow LED | 
| ● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | 
| ● NS LED | Yes; green/red LED | 
| ● MS LED | Yes; green/red LED | 
| ● IO LED | Yes; red-green-yellow LED | 
| ● Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter | 
| Potential separation | |
| between backplane bus and electronics | No | 
| between PROFINET and all other circuits | Yes | 
| between supply and all other circuits | No | 
| Isolation | |
| Isolation tested with | 707 V DC (type test) | 
| Standards, approvals, certificates | |
| Network loading class | 3 | 
| Security level | According to Security Level 1 Test Cases V1.1.1 | 
| Ambient conditions | |
| Ambient temperature during operation | |
| ● horizontal installation, min. | -30 °C; No condensation | 
| ● horizontal installation, max. | 60 °C | 
| ● vertical installation, min. | -30 °C; No condensation | 
| ● vertical installation, max. | 50 °C | 
| Altitude during operation relating to sea level | |
| ● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 
| connection method / header | |
| ET-Connection | |
| ● via BU/BA Send | Yes; + 16 ET 200AL modules | 
| Mechanics/material | |
| Strain relief | Yes; Optional | 
| Dimensions | |
| Width | 50 mm | 
| Height | 117 mm | 
| Depth | 74 mm | 
| Weights | |
| Weight, approx. | 120 g; without BusAdapter | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |