The SIPLUS ET 200SP IM 155-6PN ST (BA) TX RAIL is designed mainly for standard PROFINET applications with average station expansion of up to 32 modules (max. 512 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.
The SIPLUS ET 200SP IM 155-6PN HF T1 RAIL/ET 200SP IM 155-6PN HF TX RAIL are designed mainly for PROFINET applications with a high, flexible demand for functions, as well as large station expansion of up to 64 modules (max. 1024 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.
| Article number | 6AG2155-6AA01-4BN0 | 6AG2155-6AU01-4BN0 | 6AG2155-6AU01-1CN0 | 6AG2155-6AU01-4CN0 |
| SIPLUS ET 200SP IM155-6PN ST BA TX RAIL | SIPLUS ET 200SP IM155-6PN ST TX RAIL | SIPLUS ET 200SP IM155-6PN HF T1 RAIL | SIPLUS ET 200SP IM155-6PN HF TX RAIL | |
| General information | ||||
| Product type designation | IM 155-6 PN ST | IM 155-6 PN ST | IM 155-6 PN/2 HF | IM 155-6 PN/2 HF |
| Firmware version | ||||
| ● FW update possible | Yes | Yes | ||
| Product function | ||||
| ● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
| ● Module swapping during operation (hot swapping) | Yes; Single hot swapping | Yes; Single hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping |
| ● Isochronous mode | No | No | Yes | Yes |
| ● Tool changer | Yes; Docking station and docking unit | Yes; Docking station and docking unit | ||
| ● Local coupling, IO data | No | No | ||
| ● Local coupling, data records | No | No | ||
| Engineering with | ||||
| ● STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 | see entry ID: 109746275 | see entry ID: 109746275 | see entry ID: 109746275 |
| Configuration control | ||||
| via dataset | Yes | Yes | Yes | Yes |
| Supply voltage | ||||
| Rated value (DC) | 24 V | 24 V | 24 V | 24 V |
| permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
| Reverse polarity protection | Yes | Yes | Yes | Yes |
| Short-circuit protection | Yes | Yes | ||
| Mains buffering | ||||
| ● Mains/voltage failure stored energy time | 10 ms | 10 ms | 10 ms | 10 ms |
| Input current | ||||
| Current consumption (rated value) | 450 mA | 450 mA | ||
| Current consumption, max. | 550 mA | 550 mA | 700 mA | 700 mA |
| Inrush current, max. | 3.7 A | 3.7 A | 4.5 A | 4.5 A |
| I²t | 0.09 A²·s | 0.09 A²·s | 0.25 A²·s | 0.25 A²·s |
| Power | ||||
| Infeed power to the backplane bus | 4.5 W | 4.5 W | ||
| Power loss | ||||
| Power loss, typ. | 1.9 W | 1.9 W | 2.4 W | 2.4 W |
| Address area | ||||
| Address space per module | ||||
| ● Address space per module, max. | 256 byte; per input / output | 256 byte; per input / output | 288 byte; For input and output data respectively | 288 byte; For input and output data respectively |
| Address space per station | ||||
| ● Address space per station, max. | 512 byte; Dependent on configuration | 512 byte; Dependent on configuration | 1 440 byte; Dependent on configuration | 1 440 byte; Dependent on configuration |
| Hardware configuration | ||||
| Rack | ||||
| ● Modules per rack, max. | 32; + 16 ET 200AL modules | 32; + 16 ET 200AL modules | 64; + 16 ET 200AL modules | 64; + 16 ET 200AL modules |
| Submodules | ||||
| ● Number of submodules per station, max. | 256 | 256 | 256 | 256 |
| Time stamping | ||||
| Accuracy | 10 ms | 10 ms | ||
| Interfaces | ||||
| Number of PROFINET interfaces | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) |
| 1. Interface | ||||
| Interface types | ||||
| ● RJ 45 (Ethernet) | Yes; Pre-assembled BusAdapter BA 2x RJ45 | |||
| ● Number of ports | 2 | 2 | 2; via BusAdapter | 2; via BusAdapter |
| ● integrated switch | Yes | Yes | Yes | Yes |
| ● BusAdapter (PROFINET) | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC |
| Protocols | ||||
| ● PROFINET IO Device | Yes | Yes | Yes | Yes |
| ● Open IE communication | Yes | Yes | Yes | Yes |
| ● Media redundancy | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP |
| Interface types | ||||
| RJ 45 (Ethernet) | ||||
| ● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| ● 10 Mbps | Yes; for Ethernet services | Yes; for Ethernet services | No | No |
| ● 100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| ● Autonegotiation | Yes | Yes | Yes | Yes |
| ● Autocrossing | Yes | Yes | Yes | Yes |
| Protocols | ||||
| Number of connections | ||||
| ● Number of MtM communication relationships/connections, max. | 16 | 16 | ||
| PROFINET IO Device | ||||
| Services | ||||
| — IRT | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame |
| — PROFIenergy | Yes | Yes | Yes | Yes |
| — Prioritized startup | Yes | Yes | Yes | Yes |
| — Shared device | Yes | Yes | Yes | Yes |
| — Number of IO Controllers with shared device, max. | 2 | 2 | 4 | 4 |
| Redundancy mode | ||||
| ● PROFINET system redundancy (S2) | No | No | Yes; NAP S2 | Yes; NAP S2 |
| ● Redundant PROFINET configuration (R1) | No | No | ||
| ● H-Sync forwarding | Yes | Yes | ||
| Media redundancy | ||||
| — MRP | Yes | Yes | Yes | Yes |
| — MRPD | No | No | No | No |
| Open IE communication | ||||
| ● TCP/IP | Yes | Yes | Yes | Yes |
| ● SNMP | Yes | Yes | Yes | Yes |
| ● LLDP | Yes | Yes | Yes | Yes |
| Isochronous mode | ||||
| Equidistance | Yes | Yes | ||
| shortest clock pulse | 250 µs | 250 µs | ||
| max. cycle | 4 ms | 4 ms | ||
| Bus cycle time (TDP), min. | 250 µs | 250 µs | ||
| Jitter, max. | 1 µs | 1 µs | ||
| Interrupts/diagnostics/status information | ||||
| Status indicator | Yes | Yes | Yes | Yes |
| Alarms | Yes | Yes | Yes | Yes |
| Diagnostics function | Yes | Yes | Yes | Yes |
| Diagnostics indication LED | ||||
| ● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED |
| ● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED |
| ● MAINT LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED |
| ● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED |
| ● Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter |
| Potential separation | ||||
| between backplane bus and electronics | No | No | No | No |
| between PROFINET and all other circuits | Yes; 1 500 V AC | Yes; 1 500 V AC | Yes | Yes |
| between supply and all other circuits | No | No | No | No |
| Permissible potential difference | ||||
| between different circuits | Safety extra low voltage SELV | Safety extra low voltage SELV | ||
| Isolation | ||||
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) | 750 V DC (type test) and according to EN 50155 (routine test) | 750 V DC (type test) and according to EN 50155 (routine test) | 750 V DC (type test) and according to EN 50155 (routine test) |
| Standards, approvals, certificates | ||||
| Network loading class | 2 | 2 | 3 | 3 |
| Security level | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 |
| Railway application | ||||
| ● EN 50121-3-2 | Yes; EMC for rail vehicles | Yes; EMC for rail vehicles | Yes; EMC for rail vehicles | Yes; EMC for rail vehicles |
| ● EN 50121-4 | Yes; EMC for signal and telecommunications systems | Yes; EMC for signal and telecommunications systems | Yes; EMC for signal and telecommunications systems | Yes; EMC for signal and telecommunications systems |
| ● EN 50124-1 | Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC | Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC | Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC | Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
| ● EN 50125-1 | Yes; Rail vehicles – see ambient conditions | Yes; Rail vehicles – see ambient conditions | Yes; Rail vehicles – see ambient conditions | Yes; Rail vehicles – see ambient conditions |
| ● EN 50125-2 | Yes; Stationary electrical equipment – see ambient conditions | Yes; Stationary electrical equipment – see ambient conditions | Yes; Stationary electrical equipment – see ambient conditions | Yes; Stationary electrical equipment – see ambient conditions |
| ● EN 50125-3 | Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) | Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) | Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) | Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
| ● EN 50155 | Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position | Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position | Yes; Rail vehicles – temperature class OT1, ST1/ST2, horizontal mounting position | Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position |
| ● EN 61373 | Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B | Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B | Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B | Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B |
| ● Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support | Yes; For proof of conformity, see Service & Support | Yes; For proof of conformity, see Service & Support | Yes; For proof of conformity, see Service & Support |
| Ambient conditions | ||||
| Ambient temperature during operation | ||||
| ● horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | -30 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) |
| ● horizontal installation, max. | 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) | 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) | 60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155) | 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) |
| ● vertical installation, min. | -40 °C; = Tmin | -40 °C; = Tmin | -30 °C; = Tmin | -40 °C; = Tmin |
| ● vertical installation, max. | 50 °C; = Tmax | 50 °C; = Tmax | 50 °C; = Tmax | 50 °C; = Tmax |
| Altitude during operation relating to sea level | ||||
| ● Installation altitude above sea level, max. | 2 000 m | 2 000 m | 2 000 m | 2 000 m |
| ● Ambient air temperature-barometric pressure-altitude | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) |
| Relative humidity | ||||
| ● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance | ||||
| Coolants and lubricants | ||||
| — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air |
| Use in stationary industrial systems | ||||
| — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * |
| — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Use on land craft, rail vehicles and special-purpose vehicles | ||||
| — to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
| — to chemically active substances according to EN 60721-3-5 | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| — to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * | Yes; Class 5S3 incl. sand, dust; * | Yes; Class 5S3 incl. sand, dust; * | Yes; Class 5S3 incl. sand, dust; * |
| — Against mechanical environmental conditions acc. to EN 60721-3-5 | Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| — against mechanical environmental conditions in agriculture acc. to ISO 15003 | Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Usage in industrial process technology | ||||
| — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) |
| — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Remark | ||||
| — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating | ||||
| ● Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability |
| ● Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection | Yes; Type 1 protection | Yes; Type 1 protection | Yes; Type 1 protection |
| ● Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 | Yes; Class PC2 protective coating acc. to EN 50155:2017 | Yes; Class PC2 protective coating acc. to EN 50155:2017 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| ● Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life |
| ● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A |
| connection method / header | ||||
| ET-Connection | ||||
| ● via BU/BA Send | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules |
| Mechanics/material | ||||
| Strain relief | Yes; Optional | Yes; Optional | ||
| Dimensions | ||||
| Width | 50 mm | 50 mm | 50 mm | 50 mm |
| Height | 117 mm | 117 mm | 117 mm | 117 mm |
| Depth | 74 mm | 74 mm | 74 mm | 74 mm |
| Weights | ||||
| Weight, approx. | 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module | 147 g; without BusAdapter | 120 g; without BusAdapter | 120 g; without BusAdapter |
| Other | ||||
| Note: | for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 | for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 | for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 | for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 |
| Weight | N/A |
|---|---|
| Dimensions | N/A |