The IM 155-6 interface module is snapped directly onto the DIN rail (7.5 x 35 mm or 15 x 35 mm).
| Article number | 6AG1155-6AA01-7BN0 | 6AG1155-6AU01-2CN0 | 6AG1155-6AU01-7CN0 | 6AG1155-6AU01-7BN0 | 6AG1155-6BA01-7CN0 | 
| SIPLUS ET 200SP IM155-6PN ST / BA | SIPLUS ET 200SP IM155-6PN HF | SIPLUS ET 200SP IM155-6PN HF | SIPLUS ET 200SP IM155-6PN ST | SIPLUS ET 200SP IM155-6DP HF | |
| General information | |||||
| Product type designation | IM 155-6 PN ST | IM 155-6 PN/2 HF | IM 155-6 PN/2 HF | IM 155-6 PN ST | IM 155-6 DP HF | 
| Firmware version | |||||
| ● FW update possible | Yes | Yes | |||
| Vendor identification (VendorID) | 002AH | ||||
| Device identifier (DeviceID) | 0313H | ||||
| Product function | |||||
| ● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | 
| ● Module swapping during operation (hot swapping) | Yes; Single hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping | Yes; Single hot swapping | Yes; Multi-hot swapping | 
| ● Isochronous mode | No | Yes | Yes | No | No | 
| ● Tool changer | Yes; Docking station and docking unit | Yes; Docking station and docking unit | |||
| ● Local coupling, IO data | No | No | |||
| ● Local coupling, data records | No | No | |||
| Engineering with | |||||
| ● STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 | see entry ID: 109746275 | see entry ID: 109746275 | see entry ID: 109746275 | see entry ID: 109746275 | 
| Configuration control | |||||
| via dataset | Yes | Yes | Yes | Yes | Yes | 
| Supply voltage | |||||
| Rated value (DC) | 24 V | 24 V | 24 V | 24 V | 24 V | 
| permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | 19.2 V | 19.2 V | 
| permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 
| Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | 
| Short-circuit protection | Yes | Yes | |||
| Mains buffering | |||||
| ● Mains/voltage failure stored energy time | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 
| Input current | |||||
| Current consumption (rated value) | 450 mA | 450 mA | |||
| Current consumption, max. | 550 mA | 700 mA | 700 mA | 550 mA | 335 mA | 
| Inrush current, max. | 3.7 A | 4.5 A | 4.5 A | 3.7 A | 1.6 A | 
| I²t | 0.09 A²·s | 0.25 A²·s | 0.25 A²·s | 0.09 A²·s | 0.038 A²·s | 
| Power | |||||
| Infeed power to the backplane bus | 4.5 W | 4.5 W | |||
| Power loss | |||||
| Power loss, typ. | 1.9 W | 2.4 W | 2.4 W | 1.9 W | 1.5 W | 
| Address area | |||||
| Address space per module | |||||
| ● Address space per module, max. | 256 byte; per input / output | 288 byte; For input and output data respectively | 288 byte; For input and output data respectively | 256 byte; per input / output | 32 byte; per input / output | 
| Address space per station | |||||
| ● Address space per station, max. | 512 byte; Dependent on configuration | 1 440 byte; Dependent on configuration | 1 440 byte; Dependent on configuration | 512 byte; Dependent on configuration | 244 byte; per input / output | 
| Hardware configuration | |||||
| Rack | |||||
| ● Modules per rack, max. | 32; + 16 ET 200AL modules | 64; + 16 ET 200AL modules | 64; + 16 ET 200AL modules | 32; + 16 ET 200AL modules | 32; + 16 ET 200AL modules | 
| Submodules | |||||
| ● Number of submodules per station, max. | 256 | 256 | 256 | 256 | |
| Time stamping | |||||
| Accuracy | 10 ms | 10 ms | |||
| Interfaces | |||||
| Number of PROFINET interfaces | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | |
| Number of PROFIBUS interfaces | 1 | ||||
| 1. Interface | |||||
| Interface types | |||||
| ● RJ 45 (Ethernet) | Yes; Pre-assembled BusAdapter BA 2x RJ45 | ||||
| ● RS 485 | Yes | ||||
| ● Number of ports | 2 | 2; via BusAdapter | 2; via BusAdapter | 2 | |
| ● integrated switch | Yes | Yes | Yes | Yes | |
| ● BusAdapter (PROFINET) | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | |
| ● Output current of the interface, max. | 90 mA | ||||
| Protocols | |||||
| ● PROFINET IO Device | Yes | Yes | Yes | Yes | |
| ● PROFIBUS DP slave | Yes | ||||
| ● Open IE communication | Yes | Yes | Yes | Yes | |
| ● Media redundancy | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | |
| Interface types | |||||
| RJ 45 (Ethernet) | |||||
| ● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| ● 10 Mbps | Yes; for Ethernet services | No | No | Yes; for Ethernet services | |
| ● 100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| ● Autonegotiation | Yes | Yes | Yes | Yes | |
| ● Autocrossing | Yes | Yes | Yes | Yes | |
| RS 485 | |||||
| ● Transmission rate, max. | 12 Mbit/s | ||||
| Protocols | |||||
| Number of connections | |||||
| ● Number of MtM communication relationships/connections, max. | 16 | 16 | |||
| PROFINET IO Device | |||||
| Services | |||||
| — IRT | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | |
| — PROFIenergy | Yes | Yes | Yes | Yes | |
| — Prioritized startup | Yes | Yes | Yes | Yes | |
| — Shared device | Yes | Yes | Yes | Yes | |
| — Number of IO Controllers with shared device, max. | 2 | 4 | 4 | 2 | |
| Redundancy mode | |||||
| ● PROFINET system redundancy (S2) | No | Yes; NAP S2 | Yes; NAP S2 | No | |
| ● Redundant PROFINET configuration (R1) | No | No | |||
| ● H-Sync forwarding | Yes | Yes | |||
| Media redundancy | |||||
| — MRP | Yes | Yes | Yes | Yes | |
| — MRPD | No | No | No | No | |
| Open IE communication | |||||
| ● TCP/IP | Yes | Yes | Yes | Yes | No | 
| ● SNMP | Yes | Yes | Yes | Yes | |
| ● LLDP | Yes | Yes | Yes | Yes | |
| PROFIBUS DP | |||||
| Services | |||||
| — SYNC capability | Yes | ||||
| — FREEZE capability | Yes | ||||
| — DPV0 | Yes | ||||
| — DPV1 | Yes | ||||
| Isochronous mode | |||||
| Equidistance | Yes | Yes | |||
| shortest clock pulse | 250 µs | 250 µs | |||
| max. cycle | 4 ms | 4 ms | |||
| Bus cycle time (TDP), min. | 250 µs | 250 µs | |||
| Jitter, max. | 1 µs | 1 µs | |||
| Interrupts/diagnostics/status information | |||||
| Status indicator | Yes | Yes | Yes | Yes | Yes | 
| Alarms | Yes | Yes | Yes | Yes | Yes | 
| Diagnostics function | Yes | Yes | Yes | Yes | Yes | 
| Diagnostics indication LED | |||||
| ● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED | 
| ● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED | 
| ● MAINT LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | 
| ● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | 
| ● Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | |
| ● Connection display DP | Yes; green DP LED | ||||
| Potential separation | |||||
| between backplane bus and electronics | No | No | No | No | No | 
| between PROFIBUS DP and all other circuit components | Yes | ||||
| between PROFINET and all other circuits | Yes; 1 500 V AC | Yes | Yes | Yes; 1 500 V AC | |
| between supply and all other circuits | No | No | No | No | No | 
| Permissible potential difference | |||||
| between different circuits | Safety extra low voltage SELV | Safety extra low voltage SELV | Safety extra low voltage SELV | ||
| Isolation | |||||
| Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | ||
| Standards, approvals, certificates | |||||
| Network loading class | 2 | 3 | 3 | 2 | |
| Security level | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | |
| Ambient conditions | |||||
| Ambient temperature during operation | |||||
| ● horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | 
| ● horizontal installation, max. | 70 °C; = Tmax | 60 °C; = Tmax | 70 °C; = Tmax | 70 °C; = Tmax | 70 °C; = Tmax | 
| ● vertical installation, min. | -40 °C; = Tmin | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin (incl. condensation/frost) | -40 °C; = Tmin | -40 °C; = Tmin (incl. condensation/frost) | 
| ● vertical installation, max. | 50 °C; = Tmax | 50 °C; = Tmax | 50 °C; = Tmax | 50 °C; = Tmax | 50 °C; = Tmax | 
| Altitude during operation relating to sea level | |||||
| ● Installation altitude above sea level, max. | 5 000 m | 5 000 m | 5 000 m | 5 000 m | 5 000 m | 
| ● Ambient air temperature-barometric pressure-altitude | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | 
| Relative humidity | |||||
| ● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 
| Resistance | |||||
| Coolants and lubricants | |||||
| — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | Yes; Incl. diesel and oil droplets in the air | 
| Use in stationary industrial systems | |||||
| — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | 
| — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | 
| — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | Yes; Class 3S4 incl. sand, dust, * | 
| — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Use on ships/at sea | |||||
| — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) | 
| — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | 
| — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * | Yes; Class 6S3 incl. sand, dust; * | Yes; Class 6S3 incl. sand, dust; * | Yes; Class 6S3 incl. sand, dust; * | Yes; Class 6S3 incl. sand, dust; * | 
| — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Usage in industrial process technology | |||||
| — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | Yes; Class 3 (excluding trichlorethylene) | 
| — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | 
| Remark | |||||
| — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | * The supplied plug covers must remain in place over the unused interfaces during operation! | 
| Conformal coating | |||||
| ● Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | Yes; Class 2 for high reliability | 
| ● Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection | Yes; Type 1 protection | Yes; Type 1 protection | Yes; Type 1 protection | Yes; Type 1 protection | 
| ● Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | Yes; Discoloration of coating possible during service life | 
| ● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | Yes; Conformal coating, Class A | 
| connection method / header | |||||
| ET-Connection | |||||
| ● via BU/BA Send | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | 
| Mechanics/material | |||||
| Strain relief | Yes; Optional | Yes; Optional | |||
| Dimensions | |||||
| Width | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 
| Height | 117 mm | 117 mm | 117 mm | 117 mm | 117 mm | 
| Depth | 74 mm | 74 mm | 74 mm | 74 mm | 74 mm | 
| Weights | |||||
| Weight, approx. | 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module | 120 g; without BusAdapter | 120 g; without BusAdapter | 147 g; without BusAdapter | 150 g | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |