SIMATIC HMI, KTP1200 Basic DP, Basic Panel, Key/touch operation, 12″ TFT display, 65536 colors, PROFIBUS interface, configurable as of WinCC Basic V13/ STEP 7 Basic V13, contains open-source software, which is provided free of charge see enclosed CD

Siemens HMI Basic Panel Product Specifications:

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

General information
Article number 6AV2123-2MA03-0AX0
Product type designation KTP1200 Basic color DP
Display
Design of display TFT widescreen display, LED backlighting
Screen diagonal 12 in
Display width 261.1 mm
Display height 163.2 mm
Number of colors 65 536
Resolution (pixels)
● Horizontal image resolution 1 280 pixel
● Vertical image resolution 800 pixel
Backlighting
● MTBF backlighting (at 25 °C) 20 000 h
● Backlight dimmable Yes
Control elements
Keyboard fonts
● Function keys
— Number of function keys 10
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes; Analog-resistive
Installation type/mounting
Mounting position vertical
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 550 mA
Starting current inrush I²t 0.2 A²·s
Power
Active power input, typ. 13.2 W
Processor
Processor type ARM
Memory
Flash Yes
RAM Yes
Memory available for user data 10 Mbyte
Type of output
Acoustics
● Buzzer Yes
● Speaker No
Time of day
Clock
● Hardware clock (real-time) Yes
● Software clock Yes
● retentive Yes; Back-up duration typically 6 weeks
● synchronizable Yes
Interfaces
Number of industrial Ethernet interfaces 0
Number of RS 485 interfaces 1
Number of RS 422 interfaces 1; together with RS 485
Number of RS 232 interfaces 0; with optional adapter
Number of USB interfaces 1; Up to 16 GB
Number of 20 mA interfaces (TTY) 0
Number of parallel interfaces 0
Number of other interfaces 0
Number of SD card slots 0
With software interfaces No
Industrial Ethernet
● Industrial Ethernet status LED 0
Protocols
PROFINET No
Supports protocol for PROFINET IO No
IRT No
PROFIBUS Yes
EtherNet/IP No
MPI Yes
Protocols (Ethernet)
● TCP/IP No
● DHCP No
● SNMP No
● DCP No
● LLDP No
WEB characteristics
● HTTP No
● HTML No
Redundancy mode
Media redundancy
— MRP No
Further protocols
● CAN No
● MODBUS Yes; Modicon (MODBUS RTU)
Interrupts/diagnostics/status information
Diagnoses
● Diagnostic information readable No
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front Yes
● Enclosure Type 4x at the front Yes
Standards, approvals, certificates
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Use in hazardous areas
● ATEX Zone 2 No
● ATEX Zone 22 No
● IECEx Zone 2 No
● IECEx Zone 22 No
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 No
● FM Class I Division 2 No
Marine approval
● Germanischer Lloyd (GL) Yes
● American Bureau of Shipping (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (Class NK) Yes
● Polski Rejestr Statkow (PRS) No
● Chinese Classification Society (CCS) No
Ambient conditions
Suited for indoor use Yes
Suited for outdoor use No
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 50 °C
Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 35 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %; no condensation
Operating systems
proprietary Yes
pre-installed operating system
● Windows CE No
configuration / header
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
●     STEP 7 Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
●     STEP 7 Professional (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
●     WinCC flexible Compact No
●     WinCC flexible Standard No
●     WinCC flexible Advanced● WinCC Basic (TIA Portal) No
●     WinCC Comfort (TIA Portal) Yes
●     WinCC Advanced (TIA Portal) Yes
●     WinCC Professional (TIA Portal) Yes
Yes
Languages
Online languages
● Number of online/runtime languages 10
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options
● Web browser No
● SIMATIC WinCC Sm@rtServer No
Number of Visual Basic Scripts No
Task planner Yes
● time-controlled No
● task-controlled Yes
Help system Yes
● Number of characters per info text 500
Message system
●     Number of alarm classes● Bit messages 32
— Number of bit messages ● Analog messages
— Number of analog messages 1 000
●     S7 alarm number procedure
●     System messages HMI 25
●     System event, more (SIMATIC S7, SINUMERIK, No
SIMOTION, … ) Yes
●     Number of characters per message Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
●     Number of process values per message 80
●     Acknowledgment groups 8
●     Message indicator● Message buffer Yes
— Number of entries Yes
— Circulating buffer
— retentive 256
— maintenance-free Yes
Yes
Yes
Recipe management
● Number of recipes 50
● Data records per recipe 100
● Entries per data record 100
● Size of internal recipe memory 256 kbyte
● Recipe memory expandable No
Variables
●     Number of variables per device 800
●     Number of variables per screen 100
●     Limit values● Multiplexing Yes
●     Structures Yes
●     Arrays No
Yes
Images
● Number of configurable images 250
● Permanent window/default Yes
● Global image Yes
● Pop-up images No
● Slide-in images No
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Number of objects per image 100
● Text fields Yes
● I/O fields Yes
● Graphic I/O fields (graphics list) Yes
● Symbolic I/O fields (text list) Yes
● Date/time fields Yes
● Switches Yes
● Buttons Yes
● Graphic display Yes
● Icons Yes
● Geometric objects Yes
Complex image objects
●       Number of complex objects per screen 10
●       Alarm view● Trend view Yes
●       User view Yes
●       Status/control Yes
●       Sm@rtClient view No
●       Recipe view No
●       f(x) trend view Yes
●       System diagnostics view No
●       Media Player Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
●       HTML browser No
●       PDF display No
●       IP camera display No
●       Bar graphs No
●       Sliders Yes
●       Pointer instruments No
●       Analog/digital clock No
No
Lists
● Number of text lists per project 300
● Number of entries per text list 100
● Number of graphics lists per project 100
● Number of entries per graphics list 100
Archiving
● Number of archives per device 2; One message and one process value archive
● Number of entries per archive 10 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive ● Memory location Yes
— Memory card
— USB memory No
— Ethernet Yes
● Data storage format No
— CSV
— TXT No
— RDB Yes
No
Security
● Number of user groups 50
● Number of user rights 32
● Number of users 50
● Password export/import Yes
● SIMATIC Logon No
Character sets
● Keyboard fonts
— US English Yes
Transfer (upload/download)
● MPI/PROFIBUS DP Yes
● USB No
● Ethernet No
● using external storage medium Yes
Process coupling
●     S7-1200 Yes
●     S7-1500 Yes
●     S7-200 Yes
●     S7-300/400● LOGO! Yes
●     WinAC Yes
●     SINUMERIK Yes
●     SIMOTION Yes; No access to NCK data
●     Allen Bradley (EtherNet/IP) Yes
●     Allen Bradley (DF1) No
●     Mitsubishi (MC TCP/IP) Yes
●     Mitsubishi (FX) No
●     OMRON (FINS TCP) Yes
●     OMRON (LINK/Multilink) No
●     Modicon (Modbus TCP/IP) Yes
●     Modicon (Modbus) No
Yes
Service tools/configuration aids
● Backup/Restore manually Yes
● Backup/Restore automatically No
● Simulation Yes
● Device switchover Yes
Peripherals/Options
Printer No
SIMATIC HMI MM memory card: Multi Media Card No
SIMATIC HMI SD memory card: Secure Digital memory card No
SIMATIC HMI CF memory card Compact Flash Card No
USB memory Yes
SIMATIC IPC USB Flashdrive (USB stick) Yes
SIMATIC HMI USB stick Yes
Mechanics/material
Enclosure material (front)
● Plastic Yes
● Aluminum No
● Stainless steel No
Dimensions
Width of the housing front 330 mm
Height of housing front 245 mm
Mounting cutout, width 310 mm
Mounting cutout, height 221 mm
Overall depth 60 mm
Weights
Weight (without packaging) 1 710 g
Weight (with packaging) 2.2 kg

[/fusion_table]

Weight 2.05 kg
Dimensions 29.9 × 39.8 × 9.1 cm