The SB 1232 analog output signal board converts digital signals of the S7-1200 controller into analog signals for the process.he signal boards are plugged directly into the receptacle on the front of each S7-1200 CPU.
| Article number | 6ES7232-4HA30-0XB0 | 
| Signal Board SB 1232, 1 AO | |
| General information | |
| Product type designation | SB 1232, AQ 1×12 bit | 
| Input current | |
| from backplane bus 5 V DC, typ. | 15 mA | 
| output voltage / header | |
| supply voltage of the transmitters / header | |
| ● supply current / from supply voltage for transmitter / maximum | 25 mA | 
| Power loss | |
| Power loss, typ. | 1.5 W | 
| Analog inputs | |
| Number of analog inputs | 0 | 
| Analog outputs | |
| Number of analog outputs | 1 | 
| Cycle time (all channels) max. | Voltage: 300 μS (R), 750 μS (1 uF) Current: 600 ms (1 mH); 2 ms (10 mH) | 
| Output ranges, voltage | |
| ● -10 V to +10 V | Yes | 
| Output ranges, current | |
| ● 0 to 20 mA | Yes | 
| Load impedance (in rated range of output) | |
| ● with voltage outputs, min. | 1 000 Ω | 
| ● with current outputs, max. | 600 Ω | 
| Cable length | |
| ● shielded, max. | 100 m; shielded, twisted pair | 
| Analog value generation for the outputs | |
| Conversion principle | Differential | 
| Integration and conversion time/resolution per channel | |
| ● Resolution with overrange (bit including sign), max. | 12 bit | 
| Errors/accuracies | |
| Temperature error (relative to output range), (+/-) | 25 °C ±0.5%, to 55 °C ±1% | 
| Interrupts/diagnostics/status information | |
| Alarms | Yes | 
| Diagnostics function | Yes | 
| Diagnostics indication LED | |
| ● for status of the outputs | Yes | 
| Standards, approvals, certificates | |
| CE mark | Yes | 
| CSA approval | Yes | 
| UL approval | Yes | 
| cULus | Yes | 
| FM approval | Yes | 
| RCM (formerly C-TICK) | Yes | 
| KC approval | Yes | 
| Marine approval | Yes | 
| Ambient conditions | |
| Free fall | |
| ● Fall height, max. | 0.3 m; five times, in product package | 
| Ambient temperature during operation | |
| ● min. | -20 °C | 
| ● max. | 60 °C | 
| ● horizontal installation, min. | -20 °C | 
| ● horizontal installation, max. | 60 °C | 
| ● vertical installation, min. | -20 °C | 
| ● vertical installation, max. | 50 °C | 
| Ambient temperature during storage/transportation | |
| ● min. | -40 °C | 
| ● max. | 70 °C | 
| Air pressure acc. to IEC 60068-2-13 | |
| ● Storage/transport, min. | 660 hPa | 
| ● Storage/transport, max. | 1 080 hPa | 
| Relative humidity | |
| ● Operation at 25 ℃ without condensation, max. | 95 % | 
| Pollutant concentrations | |
| ● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | 
| Mechanics/material | |
| Enclosure material (front) | |
| ● Plastic | Yes | 
| Dimensions | |
| Width | 38 mm | 
| Height | 62 mm | 
| Depth | 21 mm | 
| Weights | |
| Weight, approx. | 40 g | 
| Weight | 0.03 kg | 
|---|---|