The central processing units (CPUs) are the heart of the SIMATIC S7-1500. They execute the user program and network the controller with other automation components.
Thanks to numerous innovations, the CPUs of the SIMATIC S7-1500 deliver the ultimate plus in productivity and efficiency. The hardware is extremely compact and certified to IP20 or IP65/67 standard. These highly integrated, highly versatile modules save space in and around the cabinet and reduce the spare parts inventory costs.
Siemens PLC S7-1500 Product Specifications:
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Article number | 6ES7511-1CK01-0AB0 |
CPU 1511C-1 PN, 175 KB Prog, 1 MB Data | |
General information | |
Product type designation | CPU 1511C-1 PN |
HW functional status | FS03 |
Firmware version | V2.9 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | Yes; With minimum OB 6x cycle of 625 µs (distributed) |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7511-1CK00-0AB0 |
Configuration control | |
via dataset | Yes |
Display | |
Screen diagonal [cm] | 3.45 cm |
Control elements | |
Number of keys | 8 |
Mode buttons | 2 |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V; 20.4 V DC, for supplying the digital inputs/outputs |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms; Refers to the power supply on the CPU section |
● Repeat rate, min. | 1/s |
Input current | |
Current consumption (rated value) | 0.8 A; Without load; 9.8 A: CPU + load |
Current consumption, max. | 1 A; Without load; 10 A: CPU + load |
Inrush current, max. | 1.9 A; Rated value |
I²t | 0.34 A²·s |
Digital inputs | |
● from load voltage L+ (without load), max. | 20 mA; per group |
Digital outputs | |
● from load voltage L+, max. | 30 mA; Per group, without load |
output voltage / header | |
Rated value (DC) | 24 V |
Encoder supply | |
Number of outputs | 1; One common 24 V encoder supply |
24 V encoder supply | |
● 24 V | Yes; L+ (-0.8 V) |
● Short-circuit protection | Yes |
● Output current, max. | 1 A |
Power | |
Infeed power to the backplane bus | 10 W |
Power consumption from the backplane bus (balanced) | 8.5 W |
Power loss | |
Power loss, typ. | 11.8 W |
Memory | |
Number of slots for SIMATIC memory card | 1 |
SIMATIC memory card required | Yes |
Work memory | |
● integrated (for program) | 175 kbyte |
● integrated (for data) | 1 Mbyte |
Load memory | |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup | |
● maintenance-free | Yes |
CPU processing times | |
for bit operations, typ. | 60 ns |
for word operations, typ. | 72 ns |
for fixed point arithmetic, typ. | 96 ns |
for floating point arithmetic, typ. | 384 ns |
CPU-blocks | |
Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
● Number range | 1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999 |
● Size, max. | 1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
FB | |
● Number range | 0 … 65 535 |
● Size, max. | 175 kbyte |
FC | |
● Number range | 0 … 65 535 |
● Size, max. | 175 kbyte |
OB | |
● Size, max. | 175 kbyte |
● Number of free cycle OBs | 100 |
● Number of time alarm OBs | 20 |
● Number of delay alarm OBs | 20 |
● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 500 µs |
● Number of process alarm OBs | 50 |
● Number of DPV1 alarm OBs | 3 |
● Number of isochronous mode OBs | 1 |
● Number of technology synchronous alarm OBs | 2 |
● Number of startup OBs | 100 |
● Number of asynchronous error OBs | 4 |
● Number of synchronous error OBs | 2 |
● Number of diagnostic alarm OBs | 1 |
Nesting depth | |
● per priority class | 24 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC counter | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
S7 times | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC timer | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB |
Extended retentive data area (incl. timers, counters, flags), max. | 1 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
Flag | |
● Size, max. | 16 kbyte |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks | |
● Retentivity adjustable | Yes |
● Retentivity preset | No |
Local data | |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 1 024; max. number of modules / submodules |
I/O address area | |
● Inputs | 32 kbyte; All inputs are in the process image |
● Outputs | 32 kbyte; All outputs are in the process image |
per integrated IO subsystem | |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
per CM/CP | |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
Subprocess images | |
● Number of subprocess images, max. | 32 |
Hardware configuration | |
Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
● Via CM | 4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Number of IO Controllers | |
● integrated | 1 |
● Via CM | 4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Rack | |
● Modules per rack, max. | 32; CPU + 31 modules |
● Number of lines, max. | 1 |
PtP CM | |
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day | |
Clock | |
● Type | Hardware clock |
● Backup time | 6 wk; At 40 °C ambient temperature, typically |
● Deviation per day, max. | 10 s; Typ.: 2 s |
Operating hours counter | |
● Number | 16 |
Clock synchronization | |
● supported | Yes |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes |
Digital inputs | |
integrated channels (DI) | 16 |
Digital inputs, parameterizable | Yes |
Source/sink input | P-reading |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
Digital input functions, parameterizable | |
● Gate start/stop | Yes |
● Capture | Yes |
● Synchronization | Yes |
Input voltage | |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal “0” | -3 to +5V |
● for signal “1” | +11 to +30V |
Input current | |
● for signal “1”, typ. | 2.5 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | Yes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms |
— at “0” to “1”, min. | 4 µs; for parameterization “none” |
— at “0” to “1”, max. | 20 ms |
— at “1” to “0”, min. | 4 µs; for parameterization “none” |
— at “1” to “0”, max. | 20 ms |
for interrupt inputs | |
— parameterizable | Yes; Same as for standard inputs |
for technological functions | |
— parameterizable | Yes; Same as for standard inputs |
Cable length | |
● shielded, max. | 1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz |
● unshielded, max. | 600 m; for technological functions: No |
Digital outputs | |
Type of digital output | Transistor |
integrated channels (DO) | 16 |
Current-sourcing | Yes; Push-pull output |
Short-circuit protection | Yes; electronic/thermal |
● Response threshold, typ. | 1.6 A with standard output, 0.5 A with high-speed output; see manual for details |
Limitation of inductive shutdown voltage to | -0.8 V |
Controlling a digital input | Yes |
Accuracy of pulse duration | Up to ±100 ppm ±2 μs at high-speed output; see manual for details |
minimum pulse duration | 2 µs; With High Speed output |
Digital output functions, parameterizable | |
● Switching tripped by comparison values | Yes; As output signal of a high-speed counter |
● PWM output | Yes |
— Number, max. | 4 |
— Cycle duration, parameterizable | Yes |
— ON period, min. | 0 % |
— ON period, max. | 100 % |
— Resolution of the duty cycle | 0.0036 %; For S7 analog format, min. 40 ns |
● Frequency output | Yes |
Switching capacity of the outputs | |
● with resistive load, max. | 0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details |
● on lamp load, max. | 5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details |
Load resistance range | |
● lower limit | 48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details |
● upper limit | 12 kΩ |
Output voltage | |
● Type of output voltage | DC |
● for signal “0”, max. | 1 V; With high-speed output, i.e. when using a high-speed output; see manual for details |
● for signal “1”, min. | 23.2 V; L+ (-0.8 V) |
Output current | |
● for signal “1” rated value | 0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details |
● for signal “1” permissible range, min. | 2 mA |
● for signal “1” permissible range, max. | 0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details |
● for signal “0” residual current, max. | 0.5 mA |
Output delay with resistive load | |
● “0” to “1”, max. | 200 µs |
● “1” to “0”, max. | 500 µs; Load-dependent |
for technological functions | |
— “0” to “1”, max. | 5 µs; Depending on the output used, see additional description in manual |
— “1” to “0”, max. | 5 µs; Depending on the output used, see additional description in manual |
Parallel switching of two outputs | |
● for logic links | Yes; for technological functions: No |
● for uprating | No |
● for redundant control of a load | Yes; for technological functions: No |
Switching frequency | |
● with resistive load, max. | 100 kHz; For high-speed output, 100 Hz for standard output |
● with inductive load, max. | 0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve |
● on lamp load, max. | 10 Hz |
Total current of the outputs | |
● Current per channel, max. | 0.5 A; see additional description in the manual |
● Current per group, max. | 8 A; see additional description in the manual |
● Current per power supply, max. | 4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual |
for technological functions | |
— Current per channel, max. | 0.5 A; see additional description in the manual |
Relay outputs | |
● Number of relay outputs | 0 |
Cable length | |
● shielded, max. | 1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz |
● unshielded, max. | 600 m; for technological functions: No |
Analog inputs | |
Number of analog inputs | 5; 4x for U/I, 1x for R/RTD |
● For current measurement | 4; max. |
● For voltage measurement | 4; max. |
● For resistance/resistance thermometer measurement | 1 |
permissible input voltage for voltage input (destruction limit), max. | 28.8 V |
permissible input current for current input (destruction limit), max. | 40 mA |
Cycle time (all channels), min. | 1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual |
Technical unit for temperature measurement adjustable | Yes; °C/°F/K |
Input ranges (rated values), voltages | |
● 0 to +10 V | Yes; Physical measuring range: ± 10 V |
— Input resistance (0 to 10 V) | 100 kΩ |
● 1 V to 5 V | Yes; Physical measuring range: ± 10 V |
— Input resistance (1 V to 5 V) | 100 kΩ |
● -10 V to +10 V | Yes |
— Input resistance (-10 V to +10 V) | 100 kΩ |
● -5 V to +5 V | Yes; Physical measuring range: ± 10 V |
— Input resistance (-5 V to +5 V) | 100 kΩ |
Input ranges (rated values), currents | |
● 0 to 20 mA | Yes; Physical measuring range: ± 20 mA |
— Input resistance (0 to 20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
● -20 mA to +20 mA | Yes |
— Input resistance (-20 mA to +20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
● 4 mA to 20 mA | Yes; Physical measuring range: ± 20 mA |
— Input resistance (4 mA to 20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
Input ranges (rated values), resistance thermometer | |
● Ni 100 | Yes; Standard/climate |
— Input resistance (Ni 100) | 10 MΩ |
● Pt 100 | Yes; Standard/climate |
— Input resistance (Pt 100) | 10 MΩ |
Input ranges (rated values), resistors | |
● 0 to 150 ohms | Yes; Physical measuring range: 0 … 600 ohms |
— Input resistance (0 to 150 ohms) | 10 MΩ |
● 0 to 300 ohms | Yes; Physical measuring range: 0 … 600 ohms |
— Input resistance (0 to 300 ohms) | 10 MΩ |
● 0 to 600 ohms | Yes |
— Input resistance (0 to 600 ohms) | 10 MΩ |
Cable length | |
● shielded, max. | 800 m; for U/I, 200 m for R/RTD |
Analog outputs | |
integrated channels (AO) | 2 |
Voltage output, short-circuit protection | Yes |
Cycle time (all channels), min. | 1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual |
Output ranges, voltage | |
● 0 to 10 V | Yes |
● 1 V to 5 V | Yes |
● -10 V to +10 V | Yes |
Output ranges, current | |
● 0 to 20 mA | Yes |
● -20 mA to +20 mA | Yes |
● 4 mA to 20 mA | Yes |
Load impedance (in rated range of output) | |
● with voltage outputs, min. | 1 kΩ |
● with voltage outputs, capacitive load, max. | 100 nF |
● with current outputs, max. | 500 Ω |
● with current outputs, inductive load, max. | 1 mH |
Cable length | |
● shielded, max. | 200 m |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 16 bit |
● Integration time, parameterizable | Yes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels |
● Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 |
Smoothing of measured values | |
● parameterizable | Yes |
● Step: None | Yes |
● Step: low | Yes |
● Step: Medium | Yes |
● Step: High | Yes |
Analog value generation for the outputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 16 bit |
Settling time | |
● for resistive load | 1.5 ms |
● for capacitive load | 2.5 ms |
● for inductive load | 2.5 ms |
Encoder | |
Connection of signal encoders | |
● for voltage measurement | Yes |
● for current measurement as 4-wire transducer | Yes |
● for resistance measurement with two-wire connection | Yes |
● for resistance measurement with three-wire connection | Yes |
● for resistance measurement with four-wire connection | Yes |
Connectable encoders | |
● 2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Encoder signals, incremental encoder (asymmetrical) | |
● Input voltage | 24 V |
● Input frequency, max. | 100 kHz |
● Counting frequency, max. | 400 kHz; with quadruple evaluation |
● Signal filter, parameterizable | Yes |
● Incremental encoder with A/B tracks, 90° phase offset | Yes |
● Incremental encoder with A/B tracks, 90° phase offset and zero track | Yes |
● pulse encoder | Yes |
● pulse encoder with direction | Yes |
● pulse encoder with one impulse signal per count direction | Yes |
Errors/accuracies | |
Linearity error (relative to input range), (+/-) | 0.1 % |
Temperature error (relative to input range), (+/-) | 0.005 %/K |
Crosstalk between the inputs, max. | -60 dB |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.02 % |
Linearity error (relative to output range), (+/-) | 0.15 % |
Temperature error (relative to output range), (+/-) | 0.005 %/K |
Crosstalk between the outputs, max. | -80 dB |
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.05 % |
Operational error limit in overall temperature range | |
● Voltage, relative to input range, (+/-) | 0.3 % |
● Current, relative to input range, (+/-) | 0.3 % |
● Resistance, relative to input range, (+/-) | 0.3 % |
● Resistance thermometer, relative to input range, (+/-) | Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K |
● Voltage, relative to output range, (+/-) | 0.3 % |
● Current, relative to output range, (+/-) | 0.3 % |
Basic error limit (operational limit at 25 °C) | |
● Voltage, relative to input range, (+/-) | 0.2 % |
● Current, relative to input range, (+/-) | 0.2 % |
● Resistance, relative to input range, (+/-) | 0.2 % |
● Resistance thermometer, relative to input range, (+/-) | Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K |
● Voltage, relative to output range, (+/-) | 0.2 % |
● Current, relative to output range, (+/-) | 0.2 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
● Series mode interference (peak value of interference < rated value of input range), min. | 30 dB |
● Common mode voltage, max. | 10 V |
● Common mode interference, min. | 60 dB; at 400 Hz: 50 dB |
Interfaces | |
Number of PROFINET interfaces | 1 |
1. Interface | |
Interface types | |
● RJ 45 (Ethernet) | Yes; X1 |
● Number of ports | 2 |
● integrated switch | Yes |
Protocols | |
● IP protocol | Yes; IPv4 |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller | |
Services | |
— PG/OP communication | Yes |
— Isochronous mode | Yes |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Prioritized startup | Yes; Max. 32 PROFINET devices |
— Number of connectable IO Devices, max. | 128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
— Of which IO devices with IRT, max. | 64 |
— Number of connectable IO Devices for RT, max. | 128 |
— of which in line, max. | 128 |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
— Number of IO Devices per tool, max. | 8 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
Update time for IRT | |
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive |
— for send cycle of 500 µs | 500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive |
— for send cycle of 1 ms | 1 ms to 16 ms |
— for send cycle of 2 ms | 2 ms to 32 ms |
— for send cycle of 4 ms | 4 ms to 64 ms |
— With IRT and parameterization of “odd” send cycles | Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) |
Update time for RT | |
— for send cycle of 250 µs | 250 µs to 128 ms |
— for send cycle of 500 µs | 500 µs to 256 ms |
— for send cycle of 1 ms | 1 ms to 512 ms |
— for send cycle of 2 ms | 2 ms to 512 ms |
— for send cycle of 4 ms | 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes |
— Isochronous mode | No |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
— activation/deactivation of I-devices | Yes; per user program |
— Asset management record | Yes; per user program |
Interface types | |
RJ 45 (Ethernet) | |
● 100 Mbps | Yes |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Industrial Ethernet status LED | Yes |
Protocols | |
Number of connections | |
● Number of connections, max. | 96; via integrated interfaces of the CPU and connected CPs / CMs |
● Number of connections reserved for ES/HMI/web | 10 |
● Number of connections via integrated interfaces | 64 |
● Number of S7 routing paths | 16 |
Redundancy mode | |
● H-Sync forwarding | Yes |
Media redundancy | |
— Media redundancy | only via 1st interface (X1) |
— MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
— MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
— MRPD | Yes; Requirement: IRT |
— Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
— Number of stations in the ring, max. | 50 |
SIMATIC communication | |
● PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
● S7 routing | Yes |
● S7 communication, as server | Yes |
● S7 communication, as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | Yes |
— Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
— UDP multicast | Yes; Max. 5 multicast circuits |
● DHCP | Yes |
● DNS | Yes |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● Encryption | Yes; Optional |
Web server | |
● HTTP | Yes; Standard and user pages |
● HTTPS | Yes; Standard and user pages |
OPC UA | |
● Runtime license required | Yes; “Small” license required |
● OPC UA Client | Yes |
— Application authentication | Yes |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | “anonymous” or by user name & password |
— Number of connections, max. | 4 |
— Number of nodes of the client interfaces, max. | 1 000 |
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 |
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 |
— Number of simultaneous calls of the client instructions per connection (except OPC_UA_ReadList,OPC_UA_WriteList,OPC_UA_MethodCall), max. | 1 |
— Number of simultaneous calls of the client instructions OPC_UA_ReadList,OPC_UA_WriteList and OPC_UA_MethodCall, max. | 5 |
— Number of registerable nodes, max. | 5 000 |
— Number of registerable method calls of OPC_UA_MethodCall, max. | 100 |
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 |
● OPC UA Server | Yes; Data access (read, write, subscribe), method call, custom address space |
— Application authentication | Yes |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | “anonymous” or by user name & password |
— GDS support (certificate management) | Yes |
— Number of sessions, max. | 32 |
— Number of accessible variables, max. | 50 000 |
— Number of registerable nodes, max. | 10 000 |
— Number of subscriptions per session, max. | 20 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 500 ms |
— Number of server methods, max. | 20 |
— Number of inputs/outputs per server method, max. | 20 |
— Number of monitored items, max. | 1 000; for 1 s sampling interval and 1 s send interval |
— Number of server interfaces, max. | 10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace” |
— Number of nodes for user-defined server interfaces, max. | 1 000 |
● Alarms and Conditions | Yes |
— Number of program alarms | 100 |
— Number of alarms for system diagnostics | 50 |
Further protocols | |
● MODBUS | Yes; MODBUS TCP |
Isochronous mode | |
Equidistance | Yes |
S7 message functions | |
Number of login stations for message functions, max. | 32 |
Program alarms | Yes |
Number of configurable program messages, max. | 5 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 2 500 |
Number of simultaneously active program alarms | |
● Number of program alarms | 600 |
● Number of alarms for system diagnostics | 100 |
● Number of alarms for motion technology objects | 80 |
Test commissioning functions | |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | No |
Number of breakpoints | 8 |
Status/control | |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
● Number of variables, max. | |
— of which status variables, max. | 200; per job |
— of which control variables, max. | 200; per job |
Forcing | |
● Forcing | Yes |
● Forcing, variables | Peripheral inputs/outputs |
● Number of variables, max. | 200 |
Diagnostic buffer | |
● present | Yes |
● Number of entries, max. | 1 000 |
— of which powerfail-proof | 500 |
Traces | |
● Number of configurable Traces | 4; Up to 512 KB of data per trace are possible |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes |
● Hardware interrupt | Yes |
Diagnoses | |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes; for analog inputs/outputs, see description in manual |
● Short-circuit | Yes; for analog outputs, see description in manual |
● A/B transition error at incremental encoder | Yes |
Diagnostics indication LED | |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
● STOP ACTIVE LED | Yes |
● Monitoring of the supply voltage (PWR-LED) | Yes |
● Channel status display | Yes |
● for channel diagnostics | Yes; For analog inputs/outputs |
● Connection display LINK TX/RX | Yes |
Supported technology objects | |
Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● Number of available Motion Control resources for technology objects | 800 |
● Required Motion Control resources | |
— per speed-controlled axis | 40 |
— per positioning axis | 80 |
— per synchronous axis | 160 |
— per external encoder | 80 |
— per output cam | 20 |
— per cam track | 160 |
— per probe | 40 |
● Positioning axis | |
— Number of positioning axes at motion control cycle of 4 ms (typical value) | 5 |
— Number of positioning axes at motion control cycle of 8 ms (typical value) | 10 |
Controller | |
● PID_Compact | Yes; Universal PID controller with integrated optimization |
● PID_3Step | Yes; PID controller with integrated optimization for valves |
● PID-Temp | Yes; PID controller with integrated optimization for temperature |
Counting and measuring | |
● High-speed counter | Yes |
Integrated Functions | |
Counting functions | |
● Continuous counting | Yes |
● Counter response parameterizable | Yes |
● Hardware gate via digital input | Yes |
● Software gate | Yes |
● Event-controlled stop | Yes |
● Synchronization via digital input | Yes |
● Counting range, parameterizable | Yes |
Comparator | |
— Number of comparators | 2; per count channel; see manual for details |
— Direction dependency | Yes |
— Can be changed from user program | Yes |
Position detection | |
● Incremental acquisition | Yes |
● Suitable for S7-1500 Motion Control | Yes |
Measuring functions | |
● Measuring time, parameterizable | Yes |
● Dynamic measurement period adjustment | Yes |
● Number of thresholds, parameterizable | 2 |
Measuring range | |
— Frequency measurement, min. | 0.04 Hz |
— Frequency measurement, max. | 400 kHz; with quadruple evaluation |
— Cycle duration measurement, min. | 2.5 µs |
— Cycle duration measurement, max. | 25 s |
Accuracy | |
— Frequency measurement | 100 ppm; depending on measuring interval and signal evaluation |
— Cycle duration measurement | 100 ppm; depending on measuring interval and signal evaluation |
— Velocity measurement | 100 ppm; depending on measuring interval and signal evaluation |
Potential separation | |
Potential separation digital inputs | |
● between the channels | No |
● between the channels, in groups of | 16 |
Potential separation digital outputs | |
● between the channels | No |
● between the channels, in groups of | 16 |
Potential separation channels | |
● between the channels and backplane bus | Yes |
● Between the channels and load voltage L+ | No |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | -25 °C; No condensation |
● horizontal installation, max. | 60 °C; note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
● vertical installation, min. | -25 °C; No condensation |
● vertical installation, max. | 40 °C; note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— GRAPH | Yes |
Know-how protection | |
● User program protection/password protection | Yes |
● Copy protection | Yes |
● Block protection | Yes |
Access protection | |
● protection of confidential configuration data | Yes |
● Password for display | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Complete protection | Yes |
Dimensions | |
Width | 85 mm |
Height | 147 mm |
Depth | 129 mm |
Weights | |
Weight, approx. | 1 050 g |
[/fusion_table]
Weight | 1.229 kg |
---|---|
Dimensions | 18.9 × 23.8 × 17.2 cm |