| General information |
| Article Number |
6ES7288-1CR60-0AA0 |
| Product type designation |
CPU CR60 AC/DC/relay |
| Engineering with |
|
| ● Programming package |
STEP 7 Micro/WIN SMART |
| Installation type/mounting |
| Rail mounting |
Yes; Standard – DIN rail |
| Supply voltage |
| Rated value (AC) |
|
| ● 120 V AC |
Yes |
| ● 230 V AC |
Yes |
| permissible range, lower limit (AC) |
85 V |
| permissible range, upper limit (AC) |
264 V |
| Line frequency |
| ● permissible range, lower limit |
47 Hz |
| ● permissible range, upper limit |
63 Hz |
| Input current |
| Current consumption (rated value) |
160 mA; at 240 V AC |
| Current consumption, max. |
280 mA; At 120 V AC |
| Inrush current, max. |
7.3 A; at 264 V |
| Output current |
| Current output, max |
300 mA; 24 V DC Sensor Power |
| Power loss |
| Power loss, max. |
20 W |
| Memory |
| Type of memory |
DDR |
| Flash |
Yes |
| RAM |
Yes |
| Memory available for user data |
8 kbyte |
| Memory size |
12 kbyte; Program memory |
| Micro Memory Card |
Yes; microSDHC Card (optional) |
| CPU processing times |
| for bit operations, typ. |
150 ns; / instruction |
| for word operations, typ. |
1.2 µs; / instruction |
| for floating point arithmetic, typ. |
3.6 µs; / instruction |
| Address area |
| I/O address area |
| ● Inputs |
32 byte; Digital inputs |
| ● Outputs |
32 byte; Digital outputs |
| Time of day |
| Clock |
| ● Type |
Hardware clock, no battery backup |
| ● Hardware clock (real-time) |
Yes |
| ● Backup time |
7 d |
| ● Deviation per day, max. |
4 s; within 120s/month at 25 °C |
| Digital inputs |
| Number of digital inputs |
36 |
| Input voltage |
| ● Type of input voltage |
DC |
| ● Rated value (DC) |
24 V |
| ● for signal “0” |
< 5 V DC |
| ● for signal “1” |
+15 to +30 V |
| Input current |
| ● for signal “1”, typ. |
4 mA |
| Cable length |
| ● shielded, max. |
500 m; 50m shielded for HSC inputs |
| ● unshielded, max. |
300 m |
| Digital outputs |
| Number of digital outputs |
24; Relays |
| Switching capacity of the outputs |
| ● with resistive load, max. |
2 A |
| ● on lamp load, max. |
30 W; 30 W with DC, 200 W with AC |
| Relay outputs |
| ● Number of relay outputs |
24 |
| Cable length |
| ● shielded, max. |
500 m |
| ● unshielded, max. |
150 m |
| Interfaces |
| Number of industrial Ethernet interfaces |
1 |
| Number of RS 485 interfaces |
1 |
| 1. Interface |
|
| Interface type |
Ethernet |
| Isolated |
Yes; Transformer isolated, 1,500V AC |
| automatic detection of transmission rate |
Yes; 10/100 Mbit/s |
| Autonegotiation |
Yes |
| Autocrossing |
Yes |
| Interface types |
| ● RJ 45 (Ethernet) |
Yes |
| Interface |
| interface type |
RS 485 (max. 187.5 kbps) |
| Protocols |
| Supports protocol for PROFINET IO |
Yes |
| PROFIBUS |
No |
| Protocols (Ethernet) |
| ● TCP/IP |
Yes |
| communication functions / header |
| S7 communication |
| ● supported |
Yes |
| ● as server |
Yes |
| ● as client |
Yes |
| Test commissioning functions |
| Forcing |
| ● Forcing |
Yes |
| Integrated Functions |
| PID controller |
Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops |
| EMC |
| Interference immunity against discharge of static electricity |
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 |
Yes |
| — Test voltage at air discharge |
8 kV |
| — Test voltage at contact discharge |
4 kV |
| Interference immunity against high-frequency electromagnetic fields |
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 |
Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz,1.89 GHz, 50% ED (to IEC 61000-4-3) |
| Interference immunity to cable-borne interference |
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 |
Yes; 2 kV acc. to IEC 61000-4-4, burst |
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 |
Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
| Interference immunity against conducted variable disturbance induced by high-frequency fields |
| ● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 |
Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
| Emission of radio interference acc. to EN 55 011 |
| ● Limit class A, for use in industrial areas |
Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
| Emission of conducted and non-conducted interference |
| ● Interference emission via line/AC current cables |
EN 61000-6-4, interference emission: Intended for use in industrial areas. |
| Degree and class of protection |
| IP degree of protection |
IP20 |
| Ambient conditions |
| Free fall |
| ● Fall height, max. |
0.3 m; five times, in product package |
| Ambient temperature during operation |
| ● min. |
0 °C |
| ● max. |
55 °C |
| ● horizontal installation, min. |
0 °C |
| ● horizontal installation, max. |
55 °C |
| ● vertical installation, min. |
0 °C |
| ● vertical installation, max. |
45 °C |
| Ambient temperature during storage/transportation |
| ● min. |
-40 °C |
| ● max. |
70 °C |
| Air pressure acc. to IEC 60068-2-13 |
| ● Storage/transport, min. |
660 hPa |
| ● Storage/transport, max. |
1 080 hPa |
| Altitude during operation relating to sea level |
| ● Installation altitude, min. |
-1 000 m |
| ● Installation altitude, max. |
2 000 m |
| Relative humidity |
| ● Operation at 25 ℃ without condensation, max. |
95% |
| configuration / header |
| configuration / programming / header |
| Programming language |
| — LAD |
Yes |
| — FBD |
Yes |
| — STL |
Yes |
| Dimensions |
| Width |
175 mm |
| Height |
81 mm |
| Depth |
81 mm |
| Weights |
| Weight, approx. |
620 g |