$ 351.90
Features
General information | |
Product type designation | CPU ST60 DC/DC/DC |
Engineering with | |
● Programming package | STEP 7 Micro/WIN SMART |
Installation type/mounting | |
Rail mounting | Yes; Standard – DIN rail |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Input current | |
Current consumption, max. | 710 mA; 24 V DC |
Inrush current, max. | 11.5 A; at 28.8 V |
Output current | |
Current output, max. | 300 mA; 24 V DC Sensor Power |
for backplane bus (5 V DC), max. | 1.4 A; max. 5 V DC for EM bus |
Power loss | |
Power loss, max. | 20 W |
Memory | |
Type of memory | DDR |
Flash | Yes |
RAM | Yes |
Memory available for user data | 20 kbyte |
Memory size | 30 kbyte; Program memory |
Micro Memory Card | Yes; microSDHC Card (optional) |
Backup | |
● present | Yes; Maintenance free, RTC requires 7 days. |
CPU processing times | |
for bit operations, typ. | 150 ns; / instruction |
for word operations, typ. | 1.2 µs; / instruction |
for floating point arithmetic, typ. | 3.6 µs; / instruction |
Address area | |
I/O address area | |
● Inputs | 144 byte; 256 bit of digital inputs & 56 words of analog inputs |
● Outputs | 144 byte; 256 bit of digital outputs & 56 words of analog outputs |
Time of day | |
Clock | |
● Type | Hardware clock, no battery backup |
● Hardware clock (real-time) | Yes |
● Backup time | 7 d |
● Deviation per day, max. | 120 s; within 120s/month at 25 °C |
Digital inputs | |
Number of digital inputs | 36; Integrated |
● of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 36 |
Input voltage | |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal “0” | 5 V DC at 1 mA |
● for signal “1” | 15 V DC at 2.5 mA |
Input current | |
● for signal “0”, max. (permissible quiescent current) | 1 mA |
● for signal “1”, typ. | 1 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
— at “0” to “1”, min. | 0.2 ms |
— at “0” to “1”, max. | 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Yes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 HSCs at 100 kHz; 2 HSCs at 20 kHz |
Cable length | |
● shielded, max. | 500 m; 50 m for technological functions |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 24; Transistor |
● of which high-speed outputs | 3; 100 kHz Pulse Train Output |
Switching capacity of the outputs | |
● with resistive load, max. | 0.5 A |
● on lamp load, max. | 5 W |
Output voltage | |
● for signal “1”, min. | 20 V DC |
Output current | |
● for signal “1” rated value | 0.5 A |
● for signal “0” residual current, max. | 10 µA |
Output delay with resistive load | |
● “0” to “1”, max. | 3 µs; of the standard outputs, max. 3 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 1 µs |
● “1” to “0”, max. | 200 µs; of the standard outputs, max. 200 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 50 µs |
Switching frequency | |
● of the pulse outputs, with resistive load, max. | 100 kHz |
Relay outputs | |
● Number of relay outputs | 0 |
Cable length | |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Interfaces | |
Number of industrial Ethernet interfaces | 1 |
Number of RS 485 interfaces | 1 |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes; Transformer isolated, 1,500V AC |
automatic detection of transmission rate | Yes; 10/100 Mbit/s |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
Protocols | |
● PROFINET IO Controller | Yes; Since V2.4 |
● PROFINET IO Device | Yes; I-Device since V2.5 |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— Number of connectable IO Devices, max. | 8 |
— Updating time | 4 ms; The minimum value of the update time also depends on the |
communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
|
Address area | |
— Inputs, max. | 128 byte; Per device |
— Outputs, max. | 128 byte; Per device |
2. Interface | |
Interface type | RS 485 (max. 187.5 kbps) |
Interface types | |
● RS 485 | Yes |
PROFIBUS DP master | |
Services | |
— S7 communication | Yes |
Protocols | |
Supports protocol for PROFINET IO | Yes; RT Controller (since FW V2.4) & I-Device (since FW V2.5) |
PROFIBUS | Yes; Via CM DP module |
Protocols (Ethernet) | |
● TCP/IP | Yes |
communication functions / header | |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes |
Test commissioning functions | |
Status/control | |
● Status/control variable | Yes |
Forcing | |
● Forcing | Yes |
Integrated Functions | |
PID controller | Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops |
Number of pulse outputs | 3 |
Potential separation | |
Potential separation digital inputs | |
● between the channels, in groups of | 1 |
Potential separation digital outputs | |
● between the channels | No |
● between the channels, in groups of | 2 |
EMC | |
Interference immunity against discharge of static electricity | |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 |
Yes |
— Test voltage at air discharge | 8 kV |
— Test voltage at contact discharge | 4 kV |
Interference immunity against high-frequency electromagnetic fields | |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 |
Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) |
Interference immunity to cable-borne interference | |
● Interference immunity on supply lines acc. to IEC 61000- 4-4 |
Yes; 2 kV acc. to IEC 61000-4-4, burst |
● Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 |
Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas | Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Emission of conducted and non-conducted interference | |
● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Standards, approvals, certificates | |
CE mark | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. | -20 °C |
● max. | 60 °C |
● horizontal installation, min. | -20 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | -20 °C |
● vertical installation, max. | 50 °C |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Storage/transport, min. | 660 hPa |
● Storage/transport, max. | 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. | -1 000 m |
● Installation altitude, max. | 2 000 m |
Relative humidity | |
● Operation at 25 ℃ without condensation, max. | 95 % |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
Dimensions | |
Width | 175 mm |
Height | 100 mm |
Depth | 81 mm |
Weights | |
Weight, approx. | 528.2 g |
Weight | 0.530 kg |
---|
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,