| Article number |
6ES7317-2AK14-0AB0 |
|
CPU317-2 DP, 1 MB |
| General information |
|
| HW functional status |
1 |
| Firmware version |
V3.3 |
| Engineering with |
|
| ● Programming package |
STEP 7 as of V5.5 + SP1 or STEP 7 V5.2 + SP1 or higher with HSP 202 |
| Supply voltage |
|
| Rated value (DC) |
24 V |
| permissible range, lower limit (DC) |
19.2 V |
| permissible range, upper limit (DC) |
28.8 V |
| external protection for power supply lines (recommendation) |
2 A min. |
| Mains buffering |
|
| ● Mains/voltage failure stored energy time |
5 ms |
| ● Repeat rate, min. |
1 s |
| Input current |
|
| Current consumption (rated value) |
870 mA |
| Current consumption (in no-load operation), typ. |
120 mA |
| Inrush current, typ. |
4 A |
| I²t |
1 A²·s |
| Power loss |
|
| Power loss, typ. |
4.5 W |
| Memory |
|
| Work memory |
|
| ● integrated |
1 024 kbyte |
| ● expandable |
No |
| Load memory |
|
| ● Plug-in (MMC) |
Yes |
| ● Plug-in (MMC), max. |
8 Mbyte |
| ● Data management on MMC (after last programming), min. |
10 y |
| Backup |
|
| ● present |
Yes; Guaranteed by MMC (maintenance-free) |
| ● without battery |
Yes; Program and data |
| CPU processing times |
|
| for bit operations, typ. |
0.025 µs |
| for word operations, typ. |
0.03 µs |
| for fixed point arithmetic, typ. |
0.04 µs |
| for floating point arithmetic, typ. |
0.16 µs |
| CPU-blocks |
|
| Number of blocks (total) |
2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
| DB |
|
| ● Number, max. |
2 048; Number range: 1 to 16000 |
| ● Size, max. |
64 kbyte |
| FB |
|
| ● Number, max. |
2 048; Number range: 0 to 7999 |
| ● Size, max. |
64 kbyte |
| FC |
|
| ● Number, max. |
2 048; Number range: 0 to 7999 |
| ● Size, max. |
64 kbyte |
| OB |
|
| ● Number, max. |
see instruction list |
| ● Size, max. |
64 kbyte |
| ● Number of free cycle OBs |
1; OB 1 |
| ● Number of time alarm OBs |
1; OB 10 |
| ● Number of delay alarm OBs |
2; OB 20, 21 |
| ● Number of cyclic interrupt OBs |
4; OB 32, 33, 34, 35 |
| ● Number of process alarm OBs |
1; OB 40 |
| ● Number of DPV1 alarm OBs |
3; OB 55, 56, 57 |
| ● Number of isochronous mode OBs |
1; OB 61 |
| ● Number of startup OBs |
1; OB 100 |
| ● Number of asynchronous error OBs |
5; OB 80, 82, 85, 86, 87 |
| ● Number of synchronous error OBs |
2; OB 121, 122 |
| Nesting depth |
|
| ● per priority class |
16 |
| ● additional within an error OB |
4 |
| Counters, timers and their retentivity |
|
| S7 counter |
|
| ● Number |
512 |
| Retentivity |
|
| — adjustable |
Yes |
| — lower limit |
0 |
| — upper limit |
511 |
| — preset |
Z 0 to Z 7 |
| Counting range |
|
| — lower limit |
0 |
| — upper limit |
999 |
| IEC counter |
|
| ● present |
Yes |
| ● Type |
SFB |
| ● Number |
Unlimited (limited only by RAM capacity) |
| S7 times |
|
| ● Number |
512 |
| Retentivity |
|
| — adjustable |
Yes |
| — lower limit |
0 |
| — upper limit |
511 |
| — preset |
No retentivity |
| Time range |
|
| — lower limit |
10 ms |
| — upper limit |
9 990 s |
| IEC timer |
|
| ● present |
Yes |
| ● Type |
SFB |
| ● Number |
Unlimited (limited only by RAM capacity) |
| Data areas and their retentivity |
|
| Retentive data area (incl. timers, counters, flags), max. |
256 kbyte |
| Flag |
|
| ● Size, max. |
4 096 byte |
| ● Retentivity available |
Yes; From MB 0 to MB 4 095 |
| ● Retentivity preset |
MB 0 to MB 15 |
| ● Number of clock memories |
8; 1 memory byte |
| Data blocks |
|
| ● Retentivity adjustable |
Yes; via non-retain property on DB |
| ● Retentivity preset |
Yes |
| Local data |
|
| ● per priority class, max. |
32 768 byte; Max. 2048 bytes per block |
| Address area |
|
| I/O address area |
|
| ● Inputs |
8 192 byte |
| ● Outputs |
8 192 byte |
| of which distributed |
|
| — Inputs |
8 192 byte |
| — Outputs |
8 192 byte |
| Process image |
|
| ● Inputs |
8 192 byte |
| ● Outputs |
8 192 byte |
| ● Inputs, adjustable |
8 192 byte |
| ● Outputs, adjustable |
8 192 byte |
| ● Inputs, default |
256 byte |
| ● Outputs, default |
256 byte |
| Subprocess images |
|
| ● Number of subprocess images, max. |
1 |
| Digital channels |
|
| ● Inputs |
65 536 |
| — of which central |
1 024 |
| ● Outputs |
65 536 |
| — of which central |
1 024 |
| Analog channels |
|
| ● Inputs |
4 096 |
| — of which central |
256 |
| ● Outputs |
4 096 |
| — of which central |
256 |
| Hardware configuration |
|
| Number of expansion units, max. |
3 |
| Number of DP masters |
|
| ● integrated |
2 |
| ● via CP |
4 |
| Number of operable FMs and CPs (recommended) |
|
| ● FM |
8 |
| ● CP, PtP |
8 |
| ● CP, LAN |
10 |
| Rack |
|
| ● Racks, max. |
4 |
| ● Modules per rack, max. |
8 |
| Time of day |
|
| Clock |
|
| ● Hardware clock (real-time) |
Yes |
| ● retentive and synchronizable |
Yes |
| ● Backup time |
6 wk; At 40 °C ambient temperature |
| ● Deviation per day, max. |
10 s; Typ.: 2 s |
| ● Behavior of the clock following POWER-ON |
Clock continues running after POWER OFF |
| ● Behavior of the clock following expiry of backup period |
the clock continues at the time of day it had when power was switched off |
| Operating hours counter |
|
| ● Number |
4 |
| ● Number/Number range |
0 to 3 |
| ● Range of values |
0 to 2^31 hours (when using SFC 101) |
| ● Granularity |
1 h |
| ● retentive |
Yes; Must be restarted at each restart |
| Clock synchronization |
|
| ● supported |
Yes |
| ● to MPI, master |
Yes |
| ● to MPI, slave |
Yes |
| ● to DP, master |
Yes; With DP slave only slave clock |
| ● to DP, slave |
Yes |
| ● in AS, master |
Yes |
| ● in AS, slave |
Yes |
| ● on Ethernet via NTP |
No |
| Digital inputs |
|
| Number of digital inputs |
0 |
| Digital outputs |
|
| Number of digital outputs |
0 |
| Analog inputs |
|
| Number of analog inputs |
0 |
| Analog outputs |
|
| Number of analog outputs |
0 |
| Interfaces |
|
| Number of industrial Ethernet interfaces |
0 |
| Number of PROFINET interfaces |
0 |
| Number of RS 485 interfaces |
2; Combined MPI / PROFIBUS DP and PROFIBUS DP |
| Number of RS 422 interfaces |
0 |
| 1. Interface |
|
| Interface type |
Integrated RS 485 interface |
| Isolated |
Yes |
| Interface types |
|
| ● RS 485 |
Yes |
| ● Output current of the interface, max. |
200 mA |
| Protocols |
|
| ● MPI |
Yes |
| ● PROFIBUS DP master |
Yes |
| ● PROFIBUS DP slave |
Yes; A DP slave at both interfaces simultaneously is not possible |
| ● Point-to-point connection |
No |
| MPI |
|
| ● Transmission rate, max. |
12 Mbit/s |
| Services |
|
| — PG/OP communication |
Yes |
| — Routing |
Yes |
| — Global data communication |
Yes |
| — S7 basic communication |
Yes |
| — S7 communication |
Yes; Only server, configured on one side |
| — S7 communication, as client |
No; but via CP and loadable FB |
| — S7 communication, as server |
Yes |
| PROFIBUS DP master |
|
| ● Transmission rate, max. |
12 Mbit/s |
| ● Number of DP slaves, max. |
124 |
| Services |
|
| — PG/OP communication |
Yes |
| — Routing |
Yes |
| — Global data communication |
No |
| — S7 basic communication |
Yes; I blocks only |
| — S7 communication |
Yes; Only server, configured on one side |
| — S7 communication, as client |
No |
| — S7 communication, as server |
Yes |
| — Equidistance |
Yes |
| — Isochronous mode |
No |
| — SYNC/FREEZE |
Yes |
| — Activation/deactivation of DP slaves |
Yes |
| — Number of DP slaves that can be simultaneously activated/deactivated, max. |
8 |
| — Direct data exchange (slave-to-slave communication) |
Yes; as subscriber |
| — DPV1 |
Yes |
| Address area |
|
| — Inputs, max. |
8 kbyte |
| — Outputs, max. |
8 kbyte |
| User data per DP slave |
|
| — Inputs, max. |
244 byte |
| — Outputs, max. |
244 byte |
| PROFIBUS DP slave |
|
| ● Transmission rate, max. |
12 Mbit/s |
| ● automatic baud rate search |
Yes; only with passive interface |
| ● Address area, max. |
32 |
| ● User data per address area, max. |
32 byte |
| Services |
|
| — PG/OP communication |
Yes |
| — Routing |
Yes; Only with active interface |
| — Global data communication |
No |
| — S7 basic communication |
No |
| — S7 communication |
Yes; Only server, configured on one side |
| — S7 communication, as client |
No |
| — S7 communication, as server |
Yes; Connection configured on one side only |
| — Direct data exchange (slave-to-slave communication) |
Yes |
| — DPV1 |
No |
| Transfer memory |
|
| — Inputs |
244 byte |
| — Outputs |
244 byte |
| 2. Interface |
|
| Interface type |
Integrated RS 485 interface |
| Isolated |
Yes |
| Interface types |
|
| ● RS 485 |
Yes |
| ● Output current of the interface, max. |
200 mA |
| Protocols |
|
| ● MPI |
No |
| ● PROFIBUS DP master |
Yes |
| ● PROFIBUS DP slave |
Yes; A DP slave at both interfaces simultaneously is not possible |
| ● Point-to-point connection |
No |
| PROFIBUS DP master |
|
| ● Transmission rate, max. |
12 Mbit/s |
| ● Number of DP slaves, max. |
124 |
| Services |
|
| — PG/OP communication |
Yes |
| — Routing |
Yes |
| — Global data communication |
No |
| — S7 basic communication |
Yes; I blocks only |
| — S7 communication |
Yes; Only server, configured on one side |
| — S7 communication, as client |
No; but via CP and loadable FB |
| — S7 communication, as server |
Yes |
| — Equidistance |
Yes |
| — Isochronous mode |
Yes; OB 61 |
| — SYNC/FREEZE |
Yes |
| — Activation/deactivation of DP slaves |
Yes |
| — Number of DP slaves that can be simultaneously activated/deactivated, max. |
8 |
| — Direct data exchange (slave-to-slave communication) |
Yes; as subscriber |
| — DPV1 |
Yes |
| Address area |
|
| — Inputs, max. |
8 192 byte |
| — Outputs, max. |
8 192 byte |
| User data per DP slave |
|
| — Inputs, max. |
244 byte |
| — Outputs, max. |
244 byte |
| PROFIBUS DP slave |
|
| ● GSD file |
The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) |
| ● Transmission rate, max. |
12 Mbit/s |
| ● automatic baud rate search |
Yes; only with passive interface |
| ● Address area, max. |
32 |
| ● User data per address area, max. |
32 byte |
| Services |
|
| — PG/OP communication |
Yes |
| — Routing |
Yes; Only with active interface |
| — Global data communication |
No |
| — S7 basic communication |
No |
| — S7 communication |
Yes; Only server, configured on one side |
| — S7 communication, as client |
No; but via CP and loadable FB |
| — S7 communication, as server |
Yes |
| — Direct data exchange (slave-to-slave communication) |
Yes |
| — DPV1 |
No |
| Transfer memory |
|
| — Inputs |
244 byte |
| — Outputs |
244 byte |
| Protocols |
|
| PROFIsafe |
No |
| communication functions / header |
|
| PG/OP communication |
Yes |
| Data record routing |
Yes |
| Global data communication |
|
| ● supported |
Yes |
| ● Number of GD loops, max. |
8 |
| ● Number of GD packets, max. |
8 |
| ● Number of GD packets, transmitter, max. |
8 |
| ● Number of GD packets, receiver, max. |
8 |
| ● Size of GD packets, max. |
22 byte |
| ● Size of GD packet (of which consistent), max. |
22 byte |
| S7 basic communication |
|
| ● supported |
Yes |
| ● User data per job, max. |
76 byte |
| ● User data per job (of which consistent), max. |
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
| S7 communication |
|
| ● supported |
Yes |
| ● as server |
Yes |
| ● as client |
Yes; Via CP and loadable FB |
| ● User data per job, max. |
See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
| S5 compatible communication |
|
| ● supported |
Yes; via CP and loadable FC |
| Number of connections |
|
| ● overall |
32 |
| ● usable for PG communication |
31 |
| — reserved for PG communication |
1 |
| — adjustable for PG communication, min. |
1 |
| — adjustable for PG communication, max. |
31 |
| ● usable for OP communication |
31 |
| — reserved for OP communication |
1 |
| — adjustable for OP communication, min. |
1 |
| — adjustable for OP communication, max. |
31 |
| ● usable for S7 basic communication |
30 |
| — reserved for S7 basic communication |
0 |
| — adjustable for S7 basic communication, min. |
0 |
| — adjustable for S7 basic communication, max. |
30 |
| ● usable for routing |
X1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14 |
| S7 message functions |
|
| Number of login stations for message functions, max. |
32; Depending on the configured connections for PG/OP and S7 basic communication |
| Process diagnostic messages |
Yes |
| simultaneously active Alarm-S blocks, max. |
300 |
| Test commissioning functions |
|
| Status block |
Yes; Up to 2 simultaneously |
| Single step |
Yes |
| Number of breakpoints |
4 |
| Status/control |
|
| ● Status/control variable |
Yes |
| ● Variables |
Inputs, outputs, memory bits, DB, times, counters |
| ● Number of variables, max. |
30 |
| — of which status variables, max. |
30 |
| — of which control variables, max. |
14 |
| Forcing |
|
| ● Forcing |
Yes |
| ● Forcing, variables |
Inputs, outputs |
| ● Number of variables, max. |
10 |
| Diagnostic buffer |
|
| ● present |
Yes |
| ● Number of entries, max. |
500 |
| — adjustable |
No |
| — of which powerfail-proof |
100; Only the last 100 entries are retained |
| ● Number of entries readable in RUN, max. |
499 |
| — adjustable |
Yes; From 10 to 499 |
| — preset |
10 |
| Service data |
|
| ● can be read out |
Yes |
| Ambient conditions |
|
| Ambient temperature during operation |
|
| ● min. |
0 °C |
| ● max. |
60 °C |
| configuration / header |
|
| Configuration software |
|
| ● STEP 7 |
Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
| ● STEP 7 Lite |
No |
| configuration / programming / header |
|
| ● Command set |
see instruction list |
| ● Nesting levels |
8 |
| ● System functions (SFC) |
see instruction list |
| ● System function blocks (SFB) |
see instruction list |
| Programming language |
|
| — LAD |
Yes |
| — FBD |
Yes |
| — STL |
Yes |
| — SCL |
Yes |
| — CFC |
Yes |
| — GRAPH |
Yes |
| — HiGraph® |
Yes |
| Know-how protection |
|
| ● User program protection/password protection |
Yes |
| ● Block encryption |
Yes; With S7 block Privacy |
| Dimensions |
|
| Width |
40 mm |
| Height |
125 mm |
| Depth |
130 mm |
| Weights |
|
| Weight, approx. |
360 g |