| Article number |
6ES7422-1FH00-0AA0 |
6ES7422-1HH00-0AA0 |
6ES7422-1BH11-0AA0 |
6ES7422-1BL00-0AA0 |
6ES7422-7BL00-0AB0 |
|
SM422, 16DO, AC120/230V, 2A |
SM422, 16DO, AC5-230V, 5A RELAY |
SM422, 16DO, DC24V, 2A, |
SIMATIC S7-400, SM 422 |
SIMATIC S7-400, DIG.OUTPUT MOD. |
| Supply voltage |
|
|
|
|
|
| Load voltage L+ |
|
|
|
|
|
| ● Rated value (DC) |
|
60 V |
24 V |
24 V |
24 V |
| ● permissible range, lower limit (DC) |
|
1 V |
20.4 V |
20.4 V |
20.4 V |
| ● permissible range, upper limit (DC) |
|
60 V |
28.8 V |
28.8 V |
28.8 V |
| Load voltage L1 |
|
|
|
|
|
| ● Rated value (AC) |
230 V; 120/230 V AC |
230 V |
|
|
|
| ● permissible range, lower limit (AC) |
79 V |
2 V |
|
|
|
| ● permissible range, upper limit (AC) |
264 V |
264 V |
|
|
|
| ● permissible frequency range, lower limit |
47 Hz |
|
|
|
|
| ● permissible frequency range, upper limit |
63 Hz |
|
|
|
|
| Input current |
|
|
|
|
|
| from load voltage L+ (without load), max. |
1.5 mA |
|
30 mA |
30 mA |
120 mA |
| from backplane bus 5 V DC, max. |
400 mA |
1 A |
160 mA |
200 mA |
200 mA |
| Power loss |
|
|
|
|
|
| Power loss, typ. |
16 W |
4.5 W |
5 W |
4 W |
8 W |
| Digital outputs |
|
|
|
|
|
| Number of digital outputs |
16 |
16; Relays |
16 |
32 |
32 |
| Short-circuit protection |
Yes; Fuse 8 A, 250 V; per group |
No |
Yes; Clocked electronically |
Yes; Clocked electronically |
Yes; Clocked electronically |
| ● Response threshold, typ. |
|
|
2.8 to 6 A |
0.7 to 1.5 A |
0.75 to 1.5 A |
| ● required current for fuse shutdown, min. |
100 A |
|
|
|
|
| ● Response time, max. |
100 ms |
|
|
|
|
| Limitation of inductive shutdown voltage to |
|
|
-30 V |
-27 V |
L+ (-45 V) |
| Controlling a digital input |
Yes; possible |
Yes; possible |
Yes; possible |
Yes; possible |
Yes; possible |
| Size of motor starters according to NEMA, max. |
Size 5 according to NEMA |
Size 5 according to NEMA |
|
|
|
| Spare fuses |
Fuse 8 A, 250 V, quick response |
|
|
|
|
| Zero-crossing switch |
No |
|
|
|
|
| Switching capacity of the outputs |
|
|
|
|
|
| ● on lamp load, max. |
50 W |
60 W |
10 W |
5 W |
5 W |
| Load resistance range |
|
|
|
|
|
| ● lower limit |
|
|
24 Ω |
48 Ω |
48 Ω |
| ● upper limit |
|
|
4 kΩ |
4 kΩ |
4 kΩ |
| Output voltage |
|
|
|
|
|
| ● for signal “1”, min. |
L1 (-18.1 V) |
|
L+ (-0.5 V) |
L+ (-0.3 V) |
L+ (-0.8 V) |
| ● for signal “1” (at max. current), min. |
L1 (-1.3 Vrms) |
|
|
|
|
| ● for signal “1” (at min. current), min. |
L1 (-18.1 Vrms) |
|
|
|
|
| Output current |
|
|
|
|
|
| ● for signal “1” rated value |
2 A |
5 A |
2 A |
0.5 A |
0.5 A |
| ● for signal “1” permissible range, min. |
10 mA |
|
5 mA |
5 mA |
5 mA |
| ● for signal “1” permissible range, max. |
2 A |
|
2.4 A |
0.6 A |
600 A |
| ● for signal “1” permissible surge current, max. |
50 A; per cycle |
|
|
|
|
| ● for signal “0” residual current, max. |
2.6 mA |
|
0.5 mA |
0.3 mA |
0.5 mA |
| Output delay with resistive load |
|
|
|
|
|
| ● “0” to “1”, max. |
1 ms |
|
1 ms |
1 ms |
|
| ● “1” to “0”, max. |
1 AC cycle |
|
1 ms |
1 ms |
|
| Parallel switching of two outputs |
|
|
|
|
|
| ● for uprating |
|
No; Not possible |
No; Not possible |
Yes; possible (only outputs of the same group) |
Yes; possible (only outputs of the same group) |
| ● for redundant control of a load |
Yes; Possible (only outputs with the same load voltage) |
Yes; Possible (only outputs with the same load voltage) |
Yes; possible (only outputs of the same group) |
Yes; possible (only outputs of the same group) |
Yes; possible (only outputs of the same group) |
| Switching frequency |
|
|
|
|
|
| ● with resistive load, max. |
10 Hz |
10 Hz |
100 Hz |
100 Hz |
100 Hz |
| ● with inductive load, max. |
0.5 Hz |
|
0.1 Hz |
0.5 Hz |
2 Hz |
| ● with inductive load (acc. to IEC 60947-5-1, DC13), max. |
|
|
0.2 Hz; 0.2 Hz at 1 A; 0.1 Hz at 2 A |
2 Hz; 2 Hz at 0.3 A; 0.5 Hz at 0.5 A |
2 Hz |
| ● with inductive load (acc. to IEC 60947-5-1, AC15), max. |
0.5 Hz |
|
|
|
|
| ● With inductive load (to IEC 60947-5-1, DC13/AC15), max. |
|
1 Hz |
|
|
|
| ● on lamp load, max. |
1 Hz |
1 Hz |
10 Hz |
10 Hz |
2 Hz |
| ● mechanical, max. |
|
20 Hz |
|
|
|
| Total current of the outputs (per group) |
|
|
|
|
|
| all mounting positions |
|
|
|
|
|
| — up to 40 °C, max. |
4 A; 6 A with fan assembly |
10 A; 10 A with fan subassembly |
3 A |
4 A |
4 A |
| — up to 60 °C, max. |
2 A; 5 A with fan subassembly; per 4 adjacent outputs |
5 A; 10 A with fan subassembly |
2 A; 2 adjacent outputs each |
2 A; 8 adjacent outputs each |
2 A |
| Relay outputs |
|
|
|
|
|
| ● Number of operating cycles, max. |
|
100 000; 100 000 (AC-15 / DC-13); 3 000 000 mechanical |
|
|
|
| Switching capacity of contacts |
|
|
|
|
|
| — with inductive load, max. |
|
5 A; 5 A (30 V DC), 5 A (230 V AC) |
|
|
|
| — with resistive load, max. |
|
5 A; 5 A (30 V DC), 5 A (230 V AC), 1.2 A (60 V DC), 0.2 A (125 V DC) |
|
|
|
| — Thermal continuous current, max. |
|
5 A |
|
|
|
| Cable length |
|
|
|
|
|
| ● shielded, max. |
1 000 m |
1 000 m |
1 000 m |
1 000 m |
1 000 m |
| ● unshielded, max. |
600 m |
600 m |
600 m |
600 m |
600 m |
| Interrupts/diagnostics/status information |
|
|
|
|
|
| Diagnostics function |
Not parameterizable |
No |
No |
No |
Yes; Parameterizable |
| Alarms |
|
|
|
|
|
| ● Diagnostic alarm |
|
|
|
|
Yes; Parameterizable |
| ● Hardware interrupt |
|
|
|
|
Yes; Parameterizable |
| Diagnoses |
|
|
|
|
|
| ● Diagnostic information readable |
|
|
|
|
Yes |
| ● Wire-break |
|
|
|
|
Yes; <0.15 mA |
| ● Short-circuit |
|
|
|
|
Yes; > 1 A (typ.) |
| Diagnostics indication LED |
|
|
|
|
|
| ● internal fault INTF (red) |
Yes; Fuse blown |
|
|
|
Yes |
| ● external fault EXTF (red) |
Yes; Missing load voltage |
|
|
|
Yes |
| ● Status indicator digital output (green) |
|
|
|
|
Yes |
| Potential separation |
|
|
|
|
|
| Potential separation digital outputs |
|
|
|
|
|
| ● between the channels |
Yes |
Yes |
Yes |
No |
Yes |
| ● between the channels, in groups of |
4 |
2 |
8 |
32 |
8 |
| ● between the channels and backplane bus |
Yes |
Yes |
Yes |
Yes |
Yes |
| Isolation |
|
|
|
|
|
| Isolation tested with |
1 500 V AC |
1 500 V AC |
500 V DC |
500 V DC |
500 V DC |
| Dimensions |
|
|
|
|
|
| Width |
25 mm |
25 mm |
25 mm |
25 mm |
25 mm |
| Height |
290 mm |
290 mm |
290 mm |
290 mm |
290 mm |
| Depth |
210 mm |
210 mm |
210 mm |
210 mm |
210 mm |
| Weights |
|
|
|
|
|
| Weight, approx. |
800 g |
700 g |
600 g |
600 g |
600 g |