| product name | 3RT2024-1AG24 | 
| product brand name | SIRIUS | 
| product designation | Power contactor | 
| product type designation | 3RT2 | 
| General technical data |  | 
| size of contactor | S0 | 
| product extension | No | 
| ● function module for communication | 
| ● auxiliary switch | No | 
| power loss [W] for rated value of the current | 0.9 W | 
| ● at AC in hot operating state | 
| ● at AC in hot operating state per pole | 0.3 W | 
| ● without load current share typical | 7.9 W | 
| insulation voltage | 690 V | 
| ● of main circuit with degree of pollution 3 rated value | 
| ● of auxiliary circuit with degree of pollution 3 rated value | 690 V | 
| surge voltage resistance | 6 kV | 
| ● of main circuit rated value | 
| ● of auxiliary circuit rated value | 6 kV | 
| maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 | 400 V | 
| shock resistance at rectangular impulse | 7,5g / 5 ms, 4,7g / 10 ms | 
| ● at AC | 
| shock resistance with sine pulse | 11,8g / 5 ms, 7,4g / 10 ms | 
| ● at AC | 
| mechanical service life (operating cycles) | 10 000 000 | 
| ● of contactor typical | 
| ● of the contactor with added electronically optimized auxiliary switch block typical | 5 000 000 | 
| ● of the contactor with added auxiliary switch block typical | 10 000 000 | 
| reference code according to IEC 81346-2 | Q | 
| Substance Prohibitance (Date) | 10/1/2009 | 
| Ambient conditions |  | 
| installation altitude at height above sea level maximum | 2 000 m | 
| ambient temperature | -25 … +60 °C | 
| ● during operation | 
| ● during storage | -55 … +80 °C | 
| relative humidity minimum | 10% | 
| relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95% | 
| Main circuit |  | 
| number of poles for main current circuit | 3 | 
| number of NO contacts for main contacts | 3 | 
| operating voltage |  | 
| ? at AC-3 rated value maximum | 690 V | 
| ? at AC-3e rated value maximum | 690 V | 
| operational current |  | 
| ? at AC-1 at 400 V at ambient temperature 40 °C rated value | 40 A | 
| ? at AC-1 |  | 
| — up to 690 V at ambient temperature 40 °C rated value | 40 A | 
| — up to 690 V at ambient temperature 60 °C rated value | 35 A | 
| ? at AC-3 |  | 
| — at 400 V rated value | 12A | 
| — at 500 V rated value | 12A | 
| — at 690 V rated value | 9A | 
| ? at AC-3e |  | 
| — at 400 V rated value | 12A | 
| — at 500 V rated value 12A | 12A | 
| — at 690 V rated value 9A | 9A | 
| ? at AC-4 at 400 V rated value | 12.5 A | 
| ? at AC-5a up to 690 V rated value x | 12.5 A | 
| ? at AC-5b up to 400 V rated value | 9.9 A | 
| ? at AC-6a |  | 
| — up to 230 V for current peak value n=20 rated value | 11.4 A | 
| — up to 400 V for current peak value n=20 rated value | 11.4 A | 
| — up to 500 V for current peak value n=20 rated value | 11.3 A | 
| — up to 690 V for current peak value n=20 rated value | 9A | 
| ? at AC-6a | 2.9 A | 
| — up to 230 V for current peak value n=30 rated value | 7.6 A | 
| — up to 400 V for current peak value n=30 rated value | 7.6 A | 
| — up to 500 V for current peak value n=30 rated value | 7.6 A | 
| — up to 690 V for current peak value n=30 rated value | 7.6 A | 
| minimum cross-section in main circuit at maximum AC-1 rated value | 10 mm² | 
| operational current for approx. 200000 operating |  | 
| cycles at AC-4 |  | 
| ? at 400 V rated value | 5.5 A | 
| ? at 690 V rated value | 5.5 A | 
| operational current |  | 
| ? at 1 current path at DC-1 |  | 
| — at 24 V rated value | 35 A | 
| — at 110 V rated value | 4.5 A | 
| — at 220 V rated value | 1A | 
| — at 440 V rated value | 0.4 A | 
| — at 600 V rated value | 0.25 A | 
| ? with 2 current paths in series at DC-1 |  | 
| — at 24 V rated value | 35 A | 
| — at 110 V rated value | 35 A | 
| — at 220 V rated value | 5A | 
| — at 440 V rated value | 1A | 
| — at 600 V rated value | 0.8 A | 
| ? with 3 current paths in series at DC-1 |  | 
| — at 24 V rated value | 35 A | 
| — at 110 V rated value | 35 A | 
| — at 220 V rated value | 35 A | 
| — at 440 V rated value | 2.9 A | 
| — at 600 V rated value | 1.4 A | 
| ? at 1 current path at DC-3 at DC-5 |  | 
| — at 24 V rated value | 20 A | 
| — at 220 V rated value | 1A | 
| — at 440 V rated value | 0.09 A | 
| — at 600 V rated value | 0.06 A | 
| ? with 2 current paths in series at DC-3 at DC-5 |  | 
| — at 24 V rated value | 35 A | 
| — at 110 V rated value | 15 A | 
| — at 220 V rated value | 3A | 
| — at 440 V rated value | 0.27 A | 
| — at 600 V rated value | 0.16 A | 
| ? with 3 current paths in series at DC-3 at DC-5 |  | 
| — at 24 V rated value | 35 A | 
| — at 110 V rated value | 35 A | 
| — at 220 V rated value | 10A | 
| — at 440 V rated value | 0.6 A | 
| — at 600 V rated value | 0.6 A | 
| operating power |  | 
| ? at AC-3 |  | 
| — at 230 V rated value | 3 kW | 
| — at 400 V rated value | 5.5 kW | 
| — at 500 V rated value 5.5 kW | 5.5 kW | 
| — at 690 V rated value | 7.5 kW | 
| ? at AC-3e |  | 
| — at 230 V rated value | 3 kW | 
| — at 400 V rated value | 5.5 kW | 
| — at 500 V rated value | 5.5 kW | 
| — at 690 V rated value | 7.5 kW | 
| operating power for approx. 200000 operating cycles at AC-4 |  | 
| ? at 400 V rated value | 2.6 kW | 
| ? at 690 V rated value | 4.6 kW | 
| operating apparent power at AC-6a |  | 
| ? up to 230 V for current peak value n=20 rated value | 4.5 kVA | 
| ? up to 400 V for current peak value n=20 rated value | 7.8 kVA | 
| ? up to 500 V for current peak value n=20 rated value | 9.8 kVA | 
| ? up to 690 V for current peak value n=20 rated value | 10.7 kVA | 
| operating apparent power at AC-6a |  | 
| ? up to 230 V for current peak value n=30 rated value | 3 kVA | 
| ? up to 400 V for current peak value n=30 rated value | 5.2 kVA | 
| ? up to 500 V for current peak value n=30 rated value | 6.5 kVA | 
| ? up to 690 V for current peak value n=30 rated value | 9 kVA | 
| short-time withstand current in cold operating state |  | 
| up to 40 °C |  | 
| ? limited to 1 s switching at zero current maximum | 210 A; Use minimum cross-section acc. to AC-1 rated value | 
| ? limited to 5 s switching at zero current maximum | 210 A; Use minimum cross-section acc. to AC-1 rated value | 
| ? limited to 10 s switching at zero current maximum | 170 A; Use minimum cross-section acc. to AC-1 rated value | 
| ? limited to 30 s switching at zero current maximum | 126 A; Use minimum cross-section acc. to AC-1 rated value | 
| ? limited to 60 s switching at zero current maximum | 105 A; Use minimum cross-section acc. to AC-1 rated value | 
| no-load switching frequency |  | 
| ? at AC | 5 000 1/h | 
| operating frequency |  | 
| ? at AC-1 maximum | 1 000 1/h | 
| ? at AC-2 maximum | 1 000 1/h | 
| ? at AC-3 maximum | 1 000 1/h | 
| ? at AC-3e maximum | 1 000 1/h | 
| ? at AC-4 maximum | 300 1/h | 
| Control circuit/ Control |  | 
| type of voltage of the control supply voltage | AC | 
| control supply voltage at AC |  | 
| ? at 50 Hz rated value | 110 V | 
| ? at 60 Hz rated value | 110 V | 
| operating range factor control supply voltage rated |  | 
| value of magnet coil at AC |  | 
| ? at 50 Hz | 0.8 … 1.1 | 
| ? at 60 Hz | 0.85 … 1.1 | 
| apparent pick-up power of magnet coil at AC |  | 
| ? at 50 Hz | 68 VA | 
| ? at 60 Hz | 67 VA | 
| inductive power factor with closing power of the coil |  | 
| ? at 50 Hz | 0.72 | 
| ? at 60 Hz | 0.74 | 
| apparent holding power of magnet coil at AC |  | 
| ? at 50 Hz | 7.9 VA | 
| ? at 60 Hz | 6.5 VA | 
| inductive power factor with the holding power of the coil |  | 
| ? at 50 Hz | 0.25 | 
| ? at 60 Hz | 0.28 | 
| closing delay |  | 
| ? at AC | 8 … 40 ms | 
| opening delay |  | 
| ? at AC | 4 … 16 ms | 
| arcing time | 10 … 10 ms | 
| control version of the switch operating mechanism | Standard A1 – A2 | 
| Auxiliary circuit |  | 
| number of NC contacts for auxiliary contacts instantaneous contact | 2 | 
| number of NO contacts for auxiliary contacts instantaneous contact | 2 | 
| operational current at AC-12 maximum | 10:00 AM | 
| operational current at AC-15 | 6:00 AM | 
| ● at 230 V rated value | 
| ● at 400 V rated value | 3:00 AM | 
| ● at 500 V rated value | 2:00 AM | 
| ● at 690 V rated value | 1:00 AM | 
| operational current at DC-12 | 10:00 AM | 
| ● at 24 V rated value | 
| ● at 48 V rated value | 6:00 AM | 
| ● at 60 V rated value | 6:00 AM | 
| ● at 110 V rated value | 3:00 AM | 
| ● at 125 V rated value | 2:00 AM | 
| ● at 220 V rated value | 1:00 AM | 
| ● at 600 V rated value | 0.15 A | 
| operational current at DC-13 | 6:00 AM | 
| ● at 24 V rated value | 
| ● at 48 V rated value | 2:00 AM | 
| ● at 60 V rated value | 2:00 AM | 
| ● at 110 V rated value | 1:00 AM | 
| ● at 125 V rated value | 0.9 A | 
| ● at 220 V rated value | 0.3 A | 
| ● at 600 V rated value | 0.1 A | 
| contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | 
| UL/CSA ratings |  | 
| full-load current (FLA) for 3-phase AC motor | 11:00 AM | 
| ● at 480 V rated value | 
| ● at 600 V rated value | 11:00 AM | 
| yielded mechanical performance [hp] ● for single-phase AC motor | 1 hp | 
| — at 110/120 V rated value | 
| — at 230 V rated value | 2 hp | 
| ● for 3-phase AC motor | 3 hp | 
| — at 200/208 V rated value | 
| — at 220/230 V rated value | 3 hp | 
| — at 460/480 V rated value | 7.5 hp | 
| — at 575/600 V rated value | 10 hp | 
| contact rating of auxiliary contacts according to UL | A600 / Q600 | 
| Short-circuit protection |  | 
| design of the fuse link | gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA) | 
| ● for short-circuit protection of the main circuit | 
| — with type of coordination 1 required | 
| — with type of assignment 2 required | gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA) | 
| ● for short-circuit protection of the auxiliary switch required | gG: 10 A (500 V, 1 kA) | 
| Installation/ mounting/ dimensions |  | 
| mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface | 
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 | 
| ● side-by-side mounting | Yes | 
| height | 85 mm | 
| width | 45 mm | 
| depth | 141 mm | 
| required spacing | 10 mm | 
| ● with side-by-side mounting | 
| — forwards | 
| — upwards | 10 mm | 
| — downwards | 10 mm | 
| — at the side | 0 mm | 
| ● for grounded parts | 10 mm | 
| — forwards | 
| — upwards | 10 mm | 
| — at the side | 6 mm | 
| — downwards | 10 mm | 
| ● for live parts — forwards | 10 mm | 
| — upwards | 10 mm | 
| — downwards | 10 mm | 
| — at the side | 6 mm | 
| Connections/ Terminals |  | 
| type of electrical connection | screw-type terminals | 
| ● for main current circuit | 
| ● for auxiliary and control circuit | screw-type terminals | 
| ● at contactor for auxiliary contacts | Screw-type terminals | 
| ● of magnet coil | Screw-type terminals | 
| type of connectable conductor cross-sections ● for main contacts | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 
| — solid | 
| — solid or stranded | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 
| — finely stranded with core end processing | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 
| ● at AWG cables for main contacts | 2x (16 … 12), 2x (14 … 8) | 
| connectable conductor cross-section for main contacts | 1 … 10 mm² | 
| ● solid | 
| ● stranded | 1 … 10 mm² | 
| ● finely stranded with core end processing | 1 … 10 mm² | 
| connectable conductor cross-section for auxiliary contacts | 0.5 … 2.5 mm² | 
| ● solid or stranded | 
| ● finely stranded with core end processing | 0.5 … 2.5 mm² | 
| type of connectable conductor cross-sections ● for auxiliary contacts | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) | 
| — solid or stranded | 
| — finely stranded with core end processing | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) | 
| ● at AWG cables for auxiliary contacts | 2x (20 … 16), 2x (18 … 14) | 
| AWG number as coded connectable conductor cross section | 16 … 8 | 
| ● for main contacts | 
| ● for auxiliary contacts | 20 … 14 | 
| Safety related data | 
| product function |  | 
| ●                 mirror contact according to IEC 60947-4-1 | Yes No | 
| ●                 positively driven operation according to IEC 60947-5-1 | 450 000 | 
| B10 value with high demand rate according to SN 31920 proportion of dangerous failures | 40% | 
| ●                 with low demand rate according to SN 31920 | 73% | 
| ●                 with high demand rate according to SN 31920failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT | 
| T1 value for proof test interval or service life according to IEC 61508 protection class IP on the front according to IEC | 20 a IP20 | 
| 60529 touch protection on the front according to IEC 60529 suitability for use | finger-safe, for vertical contact from the front | 
| ● safety-related switching OFF | Yes |