Part number |
3RV5031-4DA10 |
3RV5031-4EA10 |
3RV5031-4FA10 |
3RV5031-4GA10 |
3RV5031-4HA10 |
product brand name |
SIRIUS |
SIRIUS |
SIRIUS |
SIRIUS |
SIRIUS |
product designation |
Circuit breaker |
Circuit breaker |
Circuit breaker |
Circuit breaker |
Circuit breaker |
design of the product |
for motor protection |
for motor protection |
for motor protection |
for motor protection |
for motor protection |
product type designation |
3RV5 |
3RV5 |
3RV5 |
3RV5 |
3RV5 |
General technical data |
|
|
|
|
size of the circuit-breaker |
S2 |
S2 |
S2 |
S2 |
S2 |
power loss [W] total typical |
12 W |
15 W |
20 W |
20 W |
20 W |
insulation voltage with degree of pollution 3 at AC rated value |
690 V |
690 V |
690 V |
690 V |
690 V |
surge voltage resistance rated value |
6 kV |
6 kV |
6 kV |
6 kV |
6 kV |
shock resistance according to IEC 60068-2-27 |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
Substance Prohibitance (Date) |
7/1/2006 |
7/1/2006 |
7/1/2006 |
7/1/2006 |
7/1/2006 |
Ambient conditions |
|
|
|
|
installation altitude at height above sea level maximum |
2 000 m |
2 000 m |
2 000 m |
2 000 m |
2 000 m |
ambient temperature |
|
|
|
|
|
? during operation |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
? during transport |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
relative humidity during operation |
10 … 95 % |
10 … 95 % |
10 … 95 % |
10 … 95 % |
10 … 95 % |
Main circuit |
|
|
|
|
number of poles for main current circuit |
3 |
3 |
3 |
3 |
3 |
adjustable current response value current of the current-dependent overload release |
18 … 25 A |
22 … 32 A |
28 … 40 A |
36 … 45 A |
40 … 50 A |
operating voltage |
|
|
|
|
|
rated value |
690 V |
690 V |
690 V |
690 V |
690 V |
at AC-3 rated value maximum |
690 V |
690 V |
690 V |
690 V |
690 V |
operating frequency rated value |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
operational current rated value 25 A |
25 A |
32 A |
40 A |
45 A |
50 A |
operational current at AC-3 at 400 V rated value |
25 A |
32 A |
40 A |
45 A |
50 A |
operating frequency at AC-3 maximum |
15 1/h |
15 1/h |
15 1/h |
15 1/h |
15 1/h |
Protective and monitoring functions |
|
|
|
|
trip class |
CLASS 10 |
CLASS 10 |
CLASS 10 |
CLASS 10 |
CLASS 10 |
design of the overload release |
thermal |
thermal |
thermal |
thermal |
thermal |
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value |
50 kA |
50 kA |
50 kA |
50 kA |
50 kA |
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value |
25 kA |
25 kA |
25 kA |
25 kA |
25 kA |
response value current of instantaneous short-circuit trip unit |
325 A |
416 A |
520 A |
585 A |
650 A |
Short-circuit protection |
|
|
|
|
product function short circuit protection |
Yes |
Yes |
Yes |
Yes |
Yes |
design of the short-circuit trip |
magnetic |
magnetic |
magnetic |
magnetic |
magnetic |
Installation/ mounting/ dimensions |
|
|
|
|
mounting position |
any |
any |
any |
any |
any |
fastening method |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
height |
140 mm |
140 mm |
140 mm |
140 mm |
140 mm |
width |
55 mm |
55 mm |
55 mm |
55 mm |
55 mm |
depth |
149 mm |
149 mm |
149 mm |
149 mm |
149 mm |
required spacing for grounded parts |
|
|
|
|
|
forwards |
140 mm |
140 mm |
140 mm |
140 mm |
140 mm |
backwards |
0 mm |
0 mm |
0 mm |
0 mm |
0 mm |
upwards |
50 mm |
50 mm |
50 mm |
50 mm |
50 mm |
at the side |
30 mm |
30 mm |
30 mm |
30 mm |
30 mm |
downwards |
50 mm |
50 mm |
50 mm |
50 mm |
50 mm |
Connections/ Terminals |
|
|
|
|
type of electrical connection |
|
|
|
|
|
for main current circuit |
screw-type terminals with box terminals |
screw-type terminals with box terminals |
screw-type terminals with box terminals |
screw-type terminals with box terminals |
screw-type terminals with box terminals |
arrangement of electrical connectors for main current circuit |
Top and bottom |
Top and bottom |
Top and bottom |
Top and bottom |
Top and bottom |
type of connectable conductor cross-sections |
|
|
|
|
|
for main contacts |
|
|
|
|
|
— solid or stranded |
2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
— finely stranded with core end processing |
2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
at AWG cables for main contacts |
2x (18 … 2), 1x (18 … 2) |
2x (18 … 2), 1x (18 … 2) |
2x (18 … 2), 1x (18 … 2) |
2x (18 … 2), 1x (18 … 2) |
2x (18 … 2), 1x (18 … 2) |
tightening torque |
|
|
|
|
|
for main contacts with screw-type terminals |
3 … 4.5 N·m |
3 … 4.5 N·m |
3 … 4.5 N·m |
3 … 4.5 N·m |
3 … 4.5 N·m |
Safety related data |
|
|
|
|
protection class IP on the front according to IEC 60529 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |