| Part number |
3RV6021-4AA10 |
3RV6021-4BA10 |
3RV6021-4CA10 |
3RV6021-4DA10 |
| product brand name |
SIRIUS |
SIRIUS |
SIRIUS |
SIRIUS |
| product designation |
Circuit breaker |
Circuit breaker |
Circuit breaker |
Circuit breaker |
| design of the product |
for motor protection |
for motor protection |
for motor protection |
for motor protection |
| product type designation |
3RV6 |
3RV6 |
3RV6 |
3RV6 |
| General technical data |
| size of the circuit-breaker |
S0 |
S0 |
S0 |
S0 |
| power loss [W] total typical |
7 W |
8 W |
8 W |
8 W |
| insulation voltage with degree of pollution 3 at AC rated value |
690 V |
690 V |
690 V |
690 V |
| surge voltage resistance rated value |
6 kV |
6 kV |
6 kV |
6 kV |
| shock resistance according to IEC 60068-2-27 |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
| Substance Prohibitance (Date) |
5/1/2012 |
5/1/2012 |
5/1/2012 |
5/1/2012 |
| Ambient conditions |
| installation altitude at height above sea level maximum |
2 000 m |
2 000 m |
2 000 m |
2 000 m |
| ambient temperature |
|
|
|
|
| ? during operation |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
| ? during transport |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
| relative humidity during operation |
10 … 95 % |
10 … 95 % |
10 … 95 % |
10 … 95 % |
| Main circuit |
| number of poles for main current circuit |
3 |
3 |
3 |
3 |
| adjustable current response value current of the current-dependent overload release |
10 … 16 A |
13 … 20 A |
16 … 22 A |
18 … 25 A |
| operating voltage |
|
|
|
|
| rated value |
690 V |
690 V |
690 V |
690 V |
| at AC-3 rated value maximum |
690 V |
690 V |
690 V |
690 V |
| operating frequency rated value |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
| operational current rated value 25 A |
16 A |
20 A |
22 A |
25 A |
| operational current at AC-3 at 400 V rated value |
16 A |
20 A |
22 A |
25 A |
| operating frequency at AC-3 maximum |
15 1/h |
15 1/h |
15 1/h |
15 1/h |
| Protective and monitoring functions |
| trip class |
CLASS 10 |
CLASS 10 |
CLASS 10 |
CLASS 10 |
| design of the overload release |
thermal |
thermal |
thermal |
thermal |
| maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value |
55 kA |
55 kA |
55 kA |
55 kA |
| operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value |
25 kA |
25 kA |
25 kA |
25 kA |
| response value current of instantaneous short-circuit trip unit |
208 A |
260 A |
286 A |
325 A |
| Short-circuit protection |
| product function short circuit protection |
Yes |
Yes |
Yes |
Yes |
| design of the short-circuit trip |
magnetic |
magnetic |
magnetic |
magnetic |
| Installation/ mounting/ dimensions |
| mounting position |
any |
any |
any |
any |
| fastening method |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
| height |
97 mm |
97 mm |
97 mm |
97 mm |
| width |
45 mm |
45 mm |
45 mm |
45 mm |
| depth |
96 mm |
96 mm |
96 mm |
96 mm |
| required spacing for grounded parts |
|
|
|
|
| forwards |
0 mm |
0 mm |
0 mm |
0 mm |
| backwards |
0 mm |
0 mm |
0 mm |
0 mm |
| upwards |
50 mm |
50 mm |
50 mm |
50 mm |
| at the side |
30 mm |
30 mm |
30 mm |
30 mm |
| downwards |
50 mm |
50 mm |
50 mm |
50 mm |
| Connections/ Terminals |
| type of electrical connection |
|
|
|
|
| for main current circuit |
screw-type terminals |
screw-type terminals |
screw-type terminals |
screw-type terminals |
| arrangement of electrical connectors for main current circuit |
Top and bottom |
Top and bottom |
Top and bottom |
Top and bottom |
| type of connectable conductor cross-sections |
|
|
|
|
| for main contacts |
|
|
|
|
| — solid or stranded |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
| — finely stranded with core end processing |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
| at AWG cables for main contacts |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
| tightening torque |
|
|
|
|
| for main contacts with screw-type terminals |
2 … 2.5 N·m |
2 … 2.5 N·m |
2 … 2.5 N·m |
2 … 2.5 N·m |
| Safety related data |
| protection class IP on the front according to IEC 60529 |
IP20 |
IP20 |
IP20 |
IP20 |
| touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
|
| Part number |
3RV6021-4EA10 |
3RV6021-4FA10 |
3RV6021-4NA10 |
3RV6021-4PA10 |
| product brand name |
SIRIUS |
SIRIUS |
SIRIUS |
SIRIUS |
| product designation |
Circuit breaker |
Circuit breaker |
Circuit breaker |
Circuit breaker |
| design of the product |
for motor protection |
for motor protection |
for motor protection |
for motor protection |
| product type designation |
3RV6 |
3RV6 |
3RV6 |
3RV6 |
| General technical data |
| size of the circuit-breaker |
S0 |
S0 |
S0 |
S0 |
| power loss [W] total typical |
11 W |
14 W |
11 W |
14 W |
| insulation voltage with degree of pollution 3 at AC rated value |
690 V |
690 V |
690 V |
690 V |
| surge voltage resistance rated value |
6 kV |
6 kV |
6 kV |
6 kV |
| shock resistance according to IEC 60068-2-27 |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
25g / 11 ms |
| Substance Prohibitance (Date) |
5/1/2012 |
5/1/2012 |
5/1/2012 |
5/1/2012 |
| Ambient conditions |
| installation altitude at height above sea level maximum |
2 000 m |
2 000 m |
2 000 m |
2 000 m |
| ambient temperature |
|
|
|
|
| ? during operation |
-20 … +60 °C |
-20 … +40 °C |
-20 … +60 °C |
-20 … +40 °C |
| ? during transport |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
-50 … +80 °C |
| relative humidity during operation |
10 … 95 % |
10 … 95 % |
10 … 95 % |
10 … 95 % |
| Main circuit |
| number of poles for main current circuit |
3 |
3 |
3 |
3 |
| adjustable current response value current of the current-dependent overload release |
27 … 32 A |
34 … 40 A |
23 … 28 A |
30 … 36 A |
| operating voltage |
|
|
|
|
| rated value |
690 V |
690 V |
690 V |
690 V |
| at AC-3 rated value maximum |
690 V |
690 V |
690 V |
690 V |
| operating frequency rated value |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
50 … 60 Hz |
| operational current rated value 25 A |
32 A |
40 A |
28 A |
36 A |
| operational current at AC-3 at 400 V rated value |
32 A |
40 A |
28 A |
36 A |
| operating frequency at AC-3 maximum |
15 1/h |
15 1/h |
15 1/h |
15 1/h |
| Protective and monitoring functions |
| trip class |
CLASS 10 |
CLASS 10 |
CLASS 10 |
CLASS 10 |
| design of the overload release |
thermal |
thermal |
thermal |
thermal |
| maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value |
55 kA |
20 kA |
55 kA |
20 kA |
| operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value |
25 kA |
10 kA |
25 kA |
10 kA |
| response value current of instantaneous short-circuit trip unit |
400 A |
480 A |
364 A |
432 A |
| Short-circuit protection |
| product function short circuit protection |
Yes |
Yes |
Yes |
Yes |
| design of the short-circuit trip |
magnetic |
magnetic |
magnetic |
magnetic |
| Installation/ mounting/ dimensions |
| mounting position |
any |
any |
any |
any |
| fastening method |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
| height |
97 mm |
97 mm |
97 mm |
97 mm |
| width |
45 mm |
45 mm |
45 mm |
45 mm |
| depth |
96 mm |
96 mm |
96 mm |
96 mm |
| required spacing for grounded parts |
|
|
|
|
| forwards |
0 mm |
0 mm |
0 mm |
0 mm |
| backwards |
0 mm |
0 mm |
0 mm |
0 mm |
| upwards |
50 mm |
70 mm |
50 mm |
70 mm |
| at the side |
30 mm |
30 mm |
30 mm |
30 mm |
| downwards |
50 mm |
70 mm |
50 mm |
70 mm |
| Connections/ Terminals |
| type of electrical connection |
|
|
|
|
| for main current circuit |
screw-type terminals |
screw-type terminals |
screw-type terminals |
screw-type terminals |
| arrangement of electrical connectors for main current circuit |
Top and bottom |
Top and bottom |
Top and bottom |
Top and bottom |
| type of connectable conductor cross-sections |
|
|
|
|
| for main contacts |
|
|
|
|
| — solid or stranded |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
| — finely stranded with core end processing |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
| at AWG cables for main contacts |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
2x (16 … 12), 2x (14 … 8) |
| tightening torque |
|
|
|
|
| for main contacts with screw-type terminals |
2 … 2.5 N·m |
2 … 2.5 N·m |
2 … 2.5 N·m |
2 … 2.5 N·m |
| Safety related data |
| protection class IP on the front according to IEC 60529 |
IP20 |
IP20 |
IP20 |
IP20 |
| touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |
finger-safe, for vertical contact from the front |