Contact Us:
sales@inosaki.com

SITOP PSU100C – Siemens Power Supply

$ 72.45

SKU 6EP1331-5BA00 Category

Features

input
type of the power supply network 1-phase AC or DC
supply voltage at AC
● minimum rated value 100 V
● maximum rated value 230 V
● initial value 85 V
● full-scale value 264 V
input voltage at DC 110 … 300 V
wide range input Yes
overvoltage overload capability 2.3 × Vin rated, 1.3 ms
buffering time for rated value of the output current in the event of
power failure minimum
20 ms
operating condition of the mains buffering at Vin = 230 V
line frequency 50/60 Hz
line frequency 47 … 63 Hz
input current
● at rated input voltage 100 V 0.28 A
● at rated input voltage 230 V 0.18 A
current limitation of inrush current at 25 °C maximum 28 A
I2t value maximum 0.7 A²·s
fuse protection type internal
fuse protection type in the feeder Recommended miniature circuit breaker: from 16 A characteristic B or from 10
A characteristic C
output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage
● at output 1 at DC rated value 24 V
output voltage adjustable No; –
relative overall tolerance of the voltage 3 %
relative control precision of the output voltage
● on slow fluctuation of input voltage 0.1 %
● on slow fluctuation of ohm loading 0.2 %
residual ripple
● maximum 200 mV
● typical 40 mV
voltage peak
● maximum 300 mV
● typical 20 mV
display version for normal operation Green LED for output voltage OK
behavior of the output voltage when switching on Overshoot of Vout approx. 5 %
response delay maximum 1 s
voltage increase time of the output voltage
● typical 25 ms
output current
● rated value 0.6 A
● rated range 0 … 0.6 A
supplied active power typical 14 W
short-term overload current
● at short-circuit during operation typical 1 A
bridging of equipment No
efficiency
efficiency in percent 82 %
power loss [W]
● at rated output voltage for rated value of the output
current typical
2.6 W
● during no-load operation maximum 0.75 W
closed-loop control
relative control precision of the output voltage with rapid
fluctuation of the input voltage by +/- 15% typical
0.1 %
relative control precision of the output voltage at load step of
resistive load 10/90/10 % typical
3 %
setting time
● load step 10 to 90% typical 3 ms
● load step 90 to 10% typical 3 ms
protection and monitoring
design of the overvoltage protection Yes, according to EN 60950-1
property of the output short-circuit proof Yes
design of short-circuit protection Electronic shutdown, automatic restart
● typical 0.7 A
safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class I
leakage current
● maximum 3.5 mA
● typical 0.4 mA
protection class IP IP20
EMC
standard
● for emitted interference EN 55022 Class B
● for mains harmonics limitation not applicable
● for interference immunity EN 61000-6-2
standards, specifications, approvals
certificate of suitability
● CE marking Yes
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-
Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2
(acc. to UL 1310)
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-
Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2
(acc. to UL 1310)
● EAC approval Yes
● NEC Class 2 Yes; according to UL1310, File E151273
type of certification
● CB-certificate Yes
MTBF at 40 °C 3 910 833 h
standards, specifications, approvals hazardous environments
certificate of suitability
● IECEx No
● ATEX No
● ULhazloc approval No
● cCSAus, Class 1, Division 2 No
● FM registration No
standards, specifications, approvals marine classification
shipbuilding approval Yes
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● French marine classification society (BV) No
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) No
standards, specifications, approvals Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]
● total 73.5 kg
● during manufacturing 2.3 kg
● during operation 71.1 kg
● after end of life 0.08 kg
ambient conditions
ambient temperature
● during operation -20 … +70; with natural convection
● during transport -40 … +85
● during storage -40 … +85
environmental category according to IEC 60721 Climate class 3K3, 5 … 95% no condensation
connection method
type of electrical connection screw terminal
● at input L, N, PE: Removable screw terminal, each for 1 x 0.5 … 2.5 mm²
● at output +: 1 screw terminal for 0.5 … 2.5 mm²; -: 2 screw terminals for 0.5 … 2.5 mm²
● for auxiliary contacts
mechanical data
width × height × depth of the enclosure 22.5 × 80 × 100 mm
installation width × mounting height 22.5 mm × 180 mm
required spacing
● top 50 mm
● bottom 50 mm
● left 0 mm
● right 0 mm
fastening method Snaps onto DIN rail EN 60715 35×7.5/15
● DIN-rail mounting Yes
● S7 rail mounting No
● wall mounting No
housing can be lined up Yes
net weight 0.12 kg
accessories
electrical accessories Removable spring-type terminal 6EP1971-5BA00

Additional information

Weight 0.120 kg
Dimensions 10 × 11 × 2.8 cm

Related Products

E3Z-R61
Banner_Q45AD9LV_1
IDS_camera_UI-5240SE Rev
Festo_Pneumatic connectors_QSLV4-1-4-8_153235-1
camera-gige-ueye-le-mb-boardlevel-m12-1
Mitutoyo_Dial Indicator Thickness Gauges_7315A
Select your currency