| Part Number |
6EP1336-2BA10 |
| Input |
|
| type of the power supply network |
1-phase AC |
| supply voltage at AC |
Automatic range selection |
| ● initial value |
|
| supply voltage |
120 V |
| ● 1 at AC rated value |
|
| ● 2 at AC rated value |
230 V |
| input voltage |
85 … 132 V |
| ● 1 at AC |
|
| ● 2 at AC |
176 … 264 V |
| design of input wide range input |
No |
| overvoltage overload capability |
2.3 × Vin rated, 1.3 ms |
| operating condition of the mains buffering |
at Vin = 120/230 V |
| buffering time for rated value of the output current in the event of power failure minimum |
20 ms |
| operating condition of the mains buffering |
at Vin = 120/230 V |
| line frequency |
50 Hz |
| ● 1 rated value |
|
| ● 2 rated value |
60 Hz |
| line frequency |
47 … 63 Hz |
| input current |
7.5 A |
| ● at rated input voltage 120 V |
|
| ● at rated input voltage 230 V |
3.5 A |
| current limitation of inrush current at 25 °C maximum |
11:00 AM |
| I2t value maximum |
10 A²·s |
| fuse protection type |
T 10 A (not accessible) |
| ● in the feeder |
Recommended miniature circuit breaker: from 10 A characteristic C or circuit-breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V) |
| Output |
|
| voltage curve at output |
Controlled, isolated DC voltage |
| output voltage at DC rated value |
24 V |
| output voltage |
24 V |
| ● at output 1 at DC rated value |
|
| relative overall tolerance of the voltage |
3% |
| relative control precision of the output voltage |
0.50% |
| ● on slow fluctuation of input voltage |
|
| ● on slow fluctuation of ohm loading |
1% |
| residual ripple |
150 mV |
| ● maximum |
|
| voltage peak |
240 mV |
| ● maximum |
|
| adjustable output voltage |
24 … 28 V |
| product function output voltage adjustable |
Yes |
| type of output voltage setting |
via potentiometer; max. 480 W |
| display version for normal operation |
Green LED for 24 V OK |
| type of signal at output |
Relay contact (NO contact, rating 50 V DC/ 0.3 A) for “24 V OK” |
| behavior of the output voltage when switching on |
No overshoot of Vout (soft start) |
| response delay maximum |
1.5 s |
| voltage increase time of the output voltage |
|
| ● typical |
50 ms |
| ● maximum |
500 ms |
| output current |
|
| ● rated value |
20 A |
| ● rated rangesupplied active power typical short-term overload current |
0 … 20 A; 24 A up to +45°C; +60 … +70 °C: Derating 5%/K |
| supplied active power typical |
480 W |
| short-term overload current |
|
| ● on short-circuiting during the start-up typical |
35 A |
| ● at short-circuit during operation typical |
35 A |
| duration of overloading capability for excess current |
|
| ● on short-circuiting during the start-up typical |
100 ms |
| ● at short-circuit during operation |
100 ms |
| product feature |
|
| ● bridging of equipment |
Yes |
| number of parallel-switched equipment resources for increasing the power |
2 |
| Efficiency |
|
| efficiency in percent |
90% |
| power loss [W] |
53 W |
| ● at rated output voltage for rated value of the output current typical |
|
| Closed-loop control |
|
| relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical |
1% |
| relative control precision of the output voltage load step of resistive load 50/100/50 % typical |
3% |
| setting time |
10 ms |
| ● maximum |
|
| Protection and monitoring |
|
| design of the overvoltage protection |
Yes, according to EN 60950-1 |
| response value current limitation typical |
21 A |
| property of the output short-circuit proof |
Yes |
| design of short-circuit protection |
Electronic shutdown, automatic restart |
| enduring short circuit current RMS value |
7:00 AM |
| ● maximum |
|
| overcurrent overload capability in normal operation |
overload capability 150 % Iout rated up to 5 s/min |
| display version for overload and short circuit |
– |
| Safety |
|
| galvanic isolation between input and output |
Yes |
| galvanic isolation |
Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
| operating resource protection class |
Class I |
| leakage current |
3.5 mA |
| ● maximum |
|
| ● typical |
1 mA |
| protection class IP |
IP20 |
| Approvals |
|
| certificate of suitability |
Yes |
| ● CE marking |
|
| ● UL approval |
Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
| ● CSA approval |
Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
| ● cCSAus, Class 1, Division 2 |
No |
| ● ATEX |
No |
| certificate of suitability |
No |
| ● IECEx |
|
| ● NEC Class 2 |
No |
| ● ULhazloc approval |
No |
| ● FM registration |
No |
| type of certification CB-certificate |
Yes |
| certificate of suitability |
|
| ● EAC approval |
Yes |
| certificate of suitability shipbuilding approval |
Yes |
| shipbuilding approval |
DNV GL |
| Marine classification association |
|
| ● American Bureau of Shipping Europe Ltd. (ABS) |
No |
| ● French marine classification society (BV) |
No |
| ● DNV GL |
Yes |
| ● Lloyds Register of Shipping (LRS) |
No |
| ● Nippon Kaiji Kyokai (NK) |
No |
| EMC |
|
| standard |
EN 55022 Class B |
| ● for emitted interference |
|
| ● for mains harmonics limitation |
EN 61000-3-2 |
| ● for interference immunity |
EN 61000-6-2 |
| environmental conditions |
|
| ambient temperature |
0 … 70 °C; with natural convection |
| ● during operation |
|
| ● during transport |
-40 … +85 °C |
| ● during storage |
-40 … +85 °C |
| environmental category according to IEC 60721 |
Climate class 3K3, 5 … 95% no condensation |
| Mechanics |
|
| type of electrical connection |
screw-type terminals |
| ● at input |
L1, N, PE: 1 screw terminal each for 0.2 … 4 mm² single-core/finely stranded |
| ● at output |
+, -: 2 screw terminals each for 0.2 … 4 mm² |
| ● for auxiliary contacts |
13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm² |
| width of the enclosure |
115 mm |
| height of the enclosure |
145 mm |
| depth of the enclosure |
150 mm |
| required spacing |
50 mm |
| ● top |
|
| ● bottom |
50 mm |
| ● left |
0 mm |
| ● right |
0 mm |
| net weight |
2.4 kg |
| product feature of the enclosure housing can be lined up |
Yes |
| fastening method |
Snaps onto DIN rail EN 60715 35×7.5/15 |
| electrical accessories |
Buffer module |
| mechanical accessories |
Device identification label 20 mm × 7 mm, pale turquoise 3RT19001SB20 |
| MTBF at 40 °C |
1 778 916 h |
| other information |
Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |