Manufacturer Part Number: Festo 8001200 #03
Festo Pressure Sensors and Vacuum Sensors: SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8
The Festo SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8, MPN 8001200, is an advanced Pressure and Vacuum Sensor engineered to ensure accurate monitoring and control in various industrial applications. Here’s a detailed description to help with SEO:
Key Features:
Benefits:
Applications:
The Festo SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8 stands out as a reliable and efficient solution for managing pressure and vacuum conditions, reflecting Festo’s commitment to high-quality and innovative industrial solutions.
| Feature | Specification | 
|---|---|
| Symbol | 00995410 00995411 00995412 | 
| Certification | RCM compliance mark c UL us – Listed (OL) | 
| CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive | 
| UKCA marking (see declaration of conformity | To UK instructions for EMC To UK RoHS instructions | 
| KC characters | KC EMC | 
| Note on materials | RoHS-compliant | 
| Measured variable | Relative pressure | 
| Method of measurement | Piezoresistive pressure sensor | 
| Pressure measuring range initial value | -0.1 MPa | 
| Pressure measuring range initial value | -1 bar | 
| Pressure measuring range initial value | -14.5 psi | 
| Pressure measuring range end value | 1.6 MPa | 
| Pressure measuring range end value | 16 bar | 
| Pressure measuring range end value | 232 psi | 
| Max. overload pressure | 20 bar | 
| overload pressure | 2 MPa | 
| overload pressure | 20 bar | 
| overload pressure | 290 psi | 
| Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | 
| Information on operating and pilot media | Operation with oil lubrication possible | 
| Temperature of medium | 0 °C … 50 °C | 
| Ambient temperature | 0 °C … 50 °C | 
| ADC resolution | 12 bit | 
| Accuracy in ± % FS | 1.5 %FS | 
| Repetition accuracy in ± %FS | 0.3 %FS | 
| Temperature co-efficient in ± %FS/K | 0.05 %FS/K | 
| Switching output | 2 x PNP or 2 x NPN switchable 2xPNP | 
| Switching function | Freely programmable | 
| Switching element function | N/C contact/N/O contact switchable | 
| Max. output current | 100 mA | 
| Analog output | 0 – 10 V 4 – 20 mA 1 – 5 V | 
| Rise time | 3 ms | 
| Max. load resistance of current output | 500 Ohm | 
| Min. load resistance of voltage output | 10 kOhm | 
| Short-circuit protection | yes | 
| Protocol | IO-Link® | 
| IO-Link®, protocol version | Device V 1.1 | 
| IO-Link®, profile | Smart sensor profile | 
| IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | 
| IO-Link®, communication mode | COM2 (38,4 kBd) | 
| IO-Link®, SIO mode support | Yes | 
| IO-Link®, port class | A | 
| IO-Link®, process data width OUT | 0 Byte | 
| IO-Link®, process data width IN | 2 Byte | 
| IO-Link®, process data content IN | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) | 
| IO-Link®, minimum cycle time | 3 ms | 
| IO-Link®, data memory required | 500 byte | 
| DC operating voltage range | 20 V … 30 V | 
| Reverse polarity protection | for all electrical connections | 
| Electrical connection 1, connection type | Plug | 
| Electrical connection 1, connection technology | M12x1 A-coded as per EN 61076-2-101 M8x1 A-coded as per EN 61076-2-104 | 
| Electrical connection 1, number of pins/wires | 4 | 
| Electrical connection for input 1, connection pattern | 00991171 00995386 | 
| Type of mounting | Optionally: Front panel mounting On service unit With thread With H-rail With wall/surface bracket | 
| Mounting position | Any | 
| Pneumatic connection | M5 M7 G1/8 R1/8 R1/4 1/8 NPT QS-4 QS-6 QS-5/32 | 
| Product weight | 65 g … 80 g | 
| Display type | Illuminated LCD LED | 
| Displayable unit(s) | MPa bar inH2O inHg kPa kgf/cm² mmHg psi | 
| Setting options | IO-Link® Teach-in Via display and pushbuttons | 
| Protection against tampering | IO-Link® PIN code | 
| Setting range threshold value | 0 % … 100 % | 
| Setting range hysteresis | 0 % … 90 % | 
| Degree of protection | IP65 IP67 | 
| Corrosion resistance class (CRC) | 2 – Moderate corrosion stress | 
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |