| Main | ||||
| Part Number | LC1D205E5C | LC1D205E7C | LC1D205F5C | LC1D205F7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | 
| use category | AC-1AC -3 | AC-1AC -3 | AC-1AC -3 | AC-1AC -3 | 
| number of poles | 3P | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 
| [Uc] control circuit voltage | 48V AC 50Hz | 48 V AC 50/60 Hz | 110V AC 50Hz | 110V AC 50/60Hz | 
| Additional information | ||||
| Motor power (kW) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 
| model | LC1D | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | None | 
| Conventional thermal current [Ith] | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 
| Rated short-time withstand current [Icw] | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 
| Fuses for use with relays | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 
| average impedance | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | III | III | 
| pollution level | 3 | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 
| Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles | 8 Mcycles | 
| Electrical life | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 
| Control loop characteristics | AC at 50 Hz | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | 
| Control voltage limit | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 
| (~50Hz pickup) power consumption (VA) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 
| (~50Hz hold) power consumption (VA) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 
| heat dissipation | 18…24W | 18…24W | 18…24W | 18…24W | 
| action time | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 
| operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 
| Wiring capacity | Power circuit: busbar terminal 2 Cable option: solid busbar cross-section: 25 x 3 mm Power circuit: cable with lug1 150 mm² Cable option: stranded wire with wire terminal 150 mm² Cable selection: Stranded wire with wire terminals Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminals Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminals Control circuit: Bolt Fastening cable selection: hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | 
| Tightening torque | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | 
| Auxiliary contact type | Does not contain | Does not contain | Does not contain | Does not contain | 
| installation method | DIN rail installation base plate installation | Chassis mounting rail installation | Chassis mounting rail installation | Chassis mounting rail installation | 
| environment | ||||
| standard | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE | CCC CE | CCC CE | CCC CE | 
| IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | 
| high | 174 mm | 174 mm | 174 mm | 174 mm | 
| width | 168.5 mm | 168.5mm | 168.5mm | 168.5mm | 
| depth | 181 mm | 181 mm | 181 mm | 181 mm | 
| Product Weight | 5.2kg | 5.2kg | 5.2kg | 5.2kg | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 21cm | 21.0cm | 21.0cm | 21.0cm | 
| Package 1 Width | 22cm | 22.0cm | 22.0cm | 22.0cm | 
| Package 1 Length | 23.5cm | 23.5cm | 23.5cm | 23.5cm | 
| Package 1 Weight | 5000g | 5101.0g | 5101.0g | 5081.0g | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| main information | ||||
| Part Number | LC1D205M5C | LC1D205M7C | LC1D205Q5C | LC1D205Q7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | 
| use category | AC-3AC -1 | AC-3AC -1 | AC-3AC -1 | AC-1AC -3 | 
| number of poles | 3P | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits | 
| [Uc] control circuit voltage | 230V AC 50Hz | 230V AC 50/60Hz | 380V AC 50Hz | 380 V AC 50/60 Hz | 
| Additional information | ||||
| Motor power (kW) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) | 
| model | LC1D | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | None | 
| Conventional thermal current [Ith] | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 275 A at <40 °C for power circuits | 
| Rated short-time withstand current [Icw] | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit | 
| Fuses for use with relays | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits | 
| average impedance | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 0.33 mΩ – Ith 275 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | III | III | 
| pollution level | 3 | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 
| Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles | 8 Mcycles | 
| Electrical life | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V | 
| Control loop characteristics | AC at 50 Hz | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | 
| Control voltage limit | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 
| (~50Hz pickup) power consumption (VA) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 
| (~50Hz hold) power consumption (VA) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 
| heat dissipation | 18…24W | 18…24W | 18…24W | 18…24W | 
| action time | 20…35 ms closed 7…15 ms open | 20…35 ms close 130 ms break | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 
| operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 
| Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal | 
| Tightening torque | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening | 
| Auxiliary contact type | Does not contain | Does not contain | Does not contain | Does not contain | 
| installation method | Chassis mounting rail installation | Chassis mounting rail installation | Chassis mounting rail installation | Chassis mounting rail installation | 
| environment | ||||
| standard | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | IEC 60947-4-1 GB 14048.4 | 
| certified product | CCC CE | CCC CE | CCC CE | CCC CE | 
| IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | 
| high | 174 mm | 174 mm | 174 mm | 174 mm | 
| width | 168.5mm | 168.5mm | 168.5mm | 168.5mm | 
| depth | 181 mm | 181 mm | 181 mm | 181 mm | 
| Product Weight | 5.2kg | 5.2kg | 5.2kg | 5.2kg | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 21.9 cm | 21.7cm | 22.4 cm | 21.221 cm | 
| Package 1 Width | 23.2 cm | 21.7cm | 21.9 cm | 22.361 cm | 
| Package 1 Length | 22.2 cm | 23.3 cm | 23.4 cm | 23.622 cm | 
| Package 1 Weight | 4.967kg | 4.859 kg | 4.952 kg | 4.961 kg | 
| Unit Type of Package 2 | PAL | PAL | PAL | PAL | 
| Number of Units in Package 2 | 12 | 12 | 12 | 12 | 
| Package 2 Height | 42.0cm | 42.0cm | 42.0cm | 42.0cm | 
| Package 2 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm | 
| Package 2 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm | 
| Package 2 Weight | 95.364 kg | 95.706 kg | 95.274 kg | 93.6 kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |